Burette
Burette
BU-A,BU-B,BU-C,BU-D,BU-E,BU-F,BU-G,BU-H,BU-J
Brand:
RUISCI
-
Click to select
- BU-A-01,10ml,Transparent,Alkali,120Pcs
- BU-A-02,25ml,Transparent,Alkali,120Pcs
- BU-A-03,50ml,Transparent,Alkali,90Pcs
- BU-A-04,100ml,Transparent,Alkali,72Pcs
- BU-B-01,10ml,Brown,Alkali,120Pcs
- BU-B-02,25ml,Brown,Alkali,120Pcs
- BU-B-03,50ml,Brown,Alkali,90Pcs
- BU-B-04,100ml,Brown,Alkali,72Pcs
- BU-C-01,10ml,Blue Line,Alkali,120Pcs
- BU-C-02,25ml,Blue Line,Alkali,120Pcs
- BU-C-03,50ml,Blue Line,Alkali,90Pcs
- BU-C-04,100ml,Blue Line,Alkali,72Pcs
- BU-D-01,10ml,Transparent,Acid,60Pcs
- BU-D-02,25ml,Transparent,Acid,60Pcs
- BU-D-03,50ml,Transparent,Acid,60Pcs
- BU-D-04,100ml,Transparent,Acid,60Pcs
- BU-E-01,10ml,Brown,Acid,60Pcs
- BU-E-02,25ml,Brown,Acid,60Pcs
- BU-E-03,50ml,Brown,Acid,60Pcs
- BU-E-04,100ml,Brown,Acid,60Pcs
- BU-F-01,10ml,Blue Line,Acid,60Pcs
- BU-F-02,25ml,Blue Line,Acid,60Pcs
- BU-F-03,50ml,Blue Line,Acid,60Pcs
- BU-F-04,100ml,Blue Line,Acid,60Pcs
- BU-G-01,10ml,Transparent,PTFE,60Pcs
- BU-G-02,25ml,Transparent,PTFE,60Pcs
- BU-G-03,50ml,Transparent,PTFE,60Pcs
- BU-G-04,100ml,Transparent,PTFE,60Pcs
- BU-H-01,10ml,Brown,PTFE,60Pcs
- BU-H-02,25ml,Brown,PTFE,60Pcs
- BU-H-03,50ml,Brown,PTFE,60Pcs
- BU-H-04,100ml,Brown,PTFE,60Pcs
- BU-J-01,10ml,Blue Line,PTFE,60Pcs
- BU-J-02,25ml,Blue Line,PTFE,60Pcs
- BU-J-03,50ml,Blue Line,PTFE,60Pcs
- BU-J-04,100ml,Blue Line,PTFE,60Pcs
- BU-A-01-E,10ml,Transparent,Alkali,1Pcs
- BU-A-02-E,25ml,Transparent,Alkali,1Pcs
- BU-A-03-E,50ml,Transparent,Alkali,1Pcs
- BU-A-04-E,100ml,Transparent,Alkali,1Pcs
- BU-B-01-E,10ml,Brown,Alkali,1Pcs
- BU-B-02-E,25ml,Brown,Alkali,1Pcs
Inventory
11256
隐藏域元素占位
Overview
Burette is a sophisticated apparatus employed in titration analysis, primarily for precisely measuring and regulating the volume of liquids, so as to conduct quantitative analysis of chemical reactions.
Features
1. Composed of glass material, it is resistant to high temperatures, acids, and alkalis. The cylinder wall is uniform and smooth, and it has high transparency.
2. The scale is distinct, facilitating observation and featuring high precision.
3. The two-color scale lines minimize parallax and enhance the accuracy of reading.
3. The inner diameter is uniformly consistent, guaranteeing the stability of the liquid outflow rate and thereby improving the accuracy of measurement.
4. Acid burette: It has a glass piston at the lower end and is applicable to acidic or oxidizing solutions but not to alkaline solutions.
5. Alkali burette: The lower end is connected with a rubber tube and a glass bead and is suitable for alkaline solutions but not for acidic or oxidizing solutions.
6. PTFE stopcock burette: Utilizing polytetrafluoroethylene (PTFE) material, it is suitable for both acidic and alkaline solutions.
7. Brown burette: Made of brown glass, it is employed for solutions that require light shielding.
Technical data

Precautions:
1. Prior to conducting the titration experiments, a sealing test should be conducted with distilled water. It can be utilized only if there is no leakage.
2. During usage, acidic reagents should be employed with acidic burettes, and alkaline reagents with alkaline burettes. Mixing is strictly prohibited.
3. Before commencing the titration, the burette should be rinsed 1 to 3 times with the reagent to minimize errors.
4. After the completion of usage, the burette needs to be cleaned promptly to avoid the corrosion of the burette by the reagent that may impact its accuracy and to prevent the cross-influence of reagents between different experiments.
5. The burette must not be subjected to heating.
6. The operational temperature of the burette should be room temperature (20°C). It is recommended to operate in an environment as close to 20°C as possible. Temperature variations may induce changes in the liquid volume and the volume of the burette, influencing the measurement precision.
7. The burette should be held vertically during use; otherwise, inaccurate readings will be obtained.
8. The rubber tube of the alkaline burette can be replaced. After replacement, it should be rinsed with distilled water to avoid the impurities from the production process of the rubber tube affecting the experiment.
keyword:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Burette
- Subtitle: Burette
- Model: BU-A,BU-B,BU-C,BU-D,BU-E,BU-F,BU-G,BU-H,BU-J
- 全部型号: BU-A-01,BU-A-02,BU-A-03,BU-A-04,BU-B-01,BU-B-02,BU-B-03,BU-B-04,BU-C-01,BU-C-02,BU-C-03,BU-C-04,BU-D-01,BU-D-02,BU-D-03,BU-D-04,BU-E-01,BU-E-02,BU-E-03,BU-E-04,BU-F-01,BU-F-02,BU-F-03,BU-F-04,BU-G-01,BU-G-02,BU-G-03,BU-G-04,BU-H-01,BU-H-02,BU-H-03,BU-H-04,BU-J-01,BU-J-02,BU-J-03,BU-J-04
Burette is a sophisticated apparatus employed in titration analysis, primarily for precisely measuring and regulating the volume of liquids, so as to conduct quantitative analysis of chemical reactions.
Burette is a sophisticated apparatus employed in titration analysis, primarily for precisely measuring and regulating the volume of liquids, so as to conduct quantitative analysis of chemical reactions.
-
1. Composed of glass material, it is resistant to high temperatures, acids, and alkalis. The cylinder wall is uniform and smooth, and it has high transparency.
2. The scale is distinct, facilitating observation and featuring high precision.
3. The two-color scale lines minimize parallax and enhance the accuracy of reading.
3. The inner diameter is uniformly consistent, guaranteeing the stability of the liquid outflow rate and thereby improving the accuracy of measurement.
4. Acid burette: It has a glass piston at the lower end and is applicable to acidic or oxidizing solutions but not to alkaline solutions.
5. Alkali burette: The lower end is connected with a rubber tube and a glass bead and is suitable for alkaline solutions but not for acidic or oxidizing solutions.
6. PTFE stopcock burette: Utilizing polytetrafluoroethylene (PTFE) material, it is suitable for both acidic and alkaline solutions.
7. Brown burette: Made of brown glass, it is employed for solutions that require light shielding. -

Precautions:
1. Prior to conducting the titration experiments, a sealing test should be conducted with distilled water. It can be utilized only if there is no leakage.
2. During usage, acidic reagents should be employed with acidic burettes, and alkaline reagents with alkaline burettes. Mixing is strictly prohibited.
3. Before commencing the titration, the burette should be rinsed 1 to 3 times with the reagent to minimize errors.
4. After the completion of usage, the burette needs to be cleaned promptly to avoid the corrosion of the burette by the reagent that may impact its accuracy and to prevent the cross-influence of reagents between different experiments.
5. The burette must not be subjected to heating.
6. The operational temperature of the burette should be room temperature (20°C). It is recommended to operate in an environment as close to 20°C as possible. Temperature variations may induce changes in the liquid volume and the volume of the burette, influencing the measurement precision.
7. The burette should be held vertically during use; otherwise, inaccurate readings will be obtained.
8. The rubber tube of the alkaline burette can be replaced. After replacement, it should be rinsed with distilled water to avoid the impurities from the production process of the rubber tube affecting the experiment.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download