Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Solid Phase Extraction(SPE)
Solid Phase Extraction(SPE)
RSEA- A,RSEA- B,RSEA- C,RSEA-AC
Brand:
RUISCI
-
Click to select
- RSEA-A-12,12,Round
- RSEA-A-24,24,Round
- RSEA-B-12,12,Ordinary
- RSEA-B-24,24,Ordinary
- RSEA-C-12,12,Stainless Steel
- RSEA-C-24,24,Stainless Steel
- RSEA-D-12,12,New
- RSEA-D-16,16,New
- RSEA-D-24,24,New
- RSEA-AC-15,Positive And Negative Pressure
Inventory
1480
隐藏域元素占位
Overview
Solid Phase Extraction (SPE) serves to separate and concentrate the target compounds from liquid samples. It is predicated on the fact that the distinct physical and chemical properties of compounds yield varying adsorption effects in solid-phase fillers. Initially, the target substances within the liquid sample are selectively adsorbed by the adsorbent in the adsorption column, and subsequently eluted with solvents to effectuate efficient separation.
Features
1. Anti-cross contamination: Independent guide columns prevent sample cross-contamination.
2. Anti-fogging vacuum chamber design, high transparency: The chamber is made of organic glass, highly transparent, and glass products are not prone to breakage. The vacuum negative pressure environment, in combination with the vacuum negative pressure environment, resists fogging and is easy to observe.
3. Efficient recovery and enrichment: Multiple channels can be independently controlled with consistent extraction speeds, convenient control and adjustment. The vacuum regulation component can adjust the vacuum degree of the working chamber in real time, thereby regulating the extraction speed.
4. High selectivity: Specific adsorbents can selectively adsorb target compounds, reducing interference from impurities.
5. High enrichment efficiency: It can enrich target compounds from low-concentration samples, improving detection sensitivity.
6. High degree of automation: Automatically completes sample loading, adsorption, elution and collection, reducing human error.
7. Wide application range: Applicable to various liquid samples and compatible with multiple analytical methods.
8. Low maintenance cost: Durable components, easy to clean, reducing maintenance.
Technical data


Equipment Inspection:
1. Appearance: Prior to utilization, inspect the exterior of the equipment to guarantee the absence of damage or leakage.
2. Connections: Examine whether all pipes, valves, and connectors are firmly attached and exhibit satisfactory sealing.
Adsorbent Selection:
1. Adsorbent: Choose the appropriate adsorbent in accordance with the properties of the target compound, such as diatomaceous earth, alumina, silica gel, C18, and others.
2. Pretreatment: Before application, adsorbents typically require pretreatment, including activation and equilibration, to ensure their performance.
Sample Preparation:
1. Sample Filtration: Ensure that the sample is clear and devoid of particulate matter. Filter when necessary.
2. Sample Volume: Control the sample volume in accordance with the capacity of the equipment and the adsorbent to prevent overloading.
Flow Rate Control:
1. Appropriate Flow Rate: Regulate the flow rate of the sample passing through the adsorption column. A flow rate ranging from 1 to 2 mL/min is generally recommended to avoid influencing the extraction outcome.
2. Uniform Flow Rate: Ensure a uniform flow rate to preclude pressure fluctuations.
Elution Conditions:
1. Eluent: Select the suitable eluent based on the polarity of the target compound to ensure effective elution.
2. Elution: Control the elution volume in accordance with the enrichment status of the target compound to avoid excessive elution.
Collection System:
1. Collection Vessels: Ensure the cleanliness of the collection vessels to evade cross-contamination.
2. Labeling: Clearly mark the sample information on the collection vessels for subsequent analysis.
Equipment Maintenance:
1. Regular Cleaning: Promptly clean the adsorption column and pipes after usage to prevent residue from affecting subsequent utilization.
2. Consumables: Periodically replace the adsorbent and sealing components to ensure the equipment's performance.
3. Calibration: Regularly calibrate the equipment to guarantee the accuracy of the flow rate and pressure.
Safe Operation:
1. Protective Gear: Wear protective eyewear, gloves, etc. during operation to avoid injury from chemical reagents.
2. Adequate Ventilation: Operate in a well-ventilated environment to prevent the accumulation of harmful gases.
keyword:
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Solid Phase Extraction(SPE)
- Subtitle: Solid Phase Extraction(SPE)
- Model: RSEA- A,RSEA- B,RSEA- C,RSEA-AC
- 全部型号: RSEA-A-12,RSEA-A-24,RSEA-B-12,RSEA-B-24,RSEA-C-12,RSEA-C-24,RSEA-C-12,RSEA-C-16,RSEA-C-24,RSEA-AC-15
Solid Phase Extraction (SPE) serves to separate and concentrate the target compounds from liquid samples.
Solid Phase Extraction (SPE) serves to separate and concentrate the target compounds from liquid samples. It is predicated on the fact that the distinct physical and chemical properties of compounds yield varying adsorption effects in solid-phase fillers. Initially, the target substances within the liquid sample are selectively adsorbed by the adsorbent in the adsorption column, and subsequently eluted with solvents to effectuate efficient separation.
-
1. Anti-cross contamination: Independent guide columns prevent sample cross-contamination.
2. Anti-fogging vacuum chamber design, high transparency: The chamber is made of organic glass, highly transparent, and glass products are not prone to breakage. The vacuum negative pressure environment, in combination with the vacuum negative pressure environment, resists fogging and is easy to observe.
3. Efficient recovery and enrichment: Multiple channels can be independently controlled with consistent extraction speeds, convenient control and adjustment. The vacuum regulation component can adjust the vacuum degree of the working chamber in real time, thereby regulating the extraction speed.
4. High selectivity: Specific adsorbents can selectively adsorb target compounds, reducing interference from impurities.
5. High enrichment efficiency: It can enrich target compounds from low-concentration samples, improving detection sensitivity.
6. High degree of automation: Automatically completes sample loading, adsorption, elution and collection, reducing human error.
7. Wide application range: Applicable to various liquid samples and compatible with multiple analytical methods.
8. Low maintenance cost: Durable components, easy to clean, reducing maintenance. -


Equipment Inspection:
1. Appearance: Prior to utilization, inspect the exterior of the equipment to guarantee the absence of damage or leakage.
2. Connections: Examine whether all pipes, valves, and connectors are firmly attached and exhibit satisfactory sealing.Adsorbent Selection:
1. Adsorbent: Choose the appropriate adsorbent in accordance with the properties of the target compound, such as diatomaceous earth, alumina, silica gel, C18, and others.
2. Pretreatment: Before application, adsorbents typically require pretreatment, including activation and equilibration, to ensure their performance.Sample Preparation:
1. Sample Filtration: Ensure that the sample is clear and devoid of particulate matter. Filter when necessary.
2. Sample Volume: Control the sample volume in accordance with the capacity of the equipment and the adsorbent to prevent overloading.Flow Rate Control:
1. Appropriate Flow Rate: Regulate the flow rate of the sample passing through the adsorption column. A flow rate ranging from 1 to 2 mL/min is generally recommended to avoid influencing the extraction outcome.
2. Uniform Flow Rate: Ensure a uniform flow rate to preclude pressure fluctuations.Elution Conditions:
1. Eluent: Select the suitable eluent based on the polarity of the target compound to ensure effective elution.
2. Elution: Control the elution volume in accordance with the enrichment status of the target compound to avoid excessive elution.Collection System:
1. Collection Vessels: Ensure the cleanliness of the collection vessels to evade cross-contamination.
2. Labeling: Clearly mark the sample information on the collection vessels for subsequent analysis.Equipment Maintenance:
1. Regular Cleaning: Promptly clean the adsorption column and pipes after usage to prevent residue from affecting subsequent utilization.
2. Consumables: Periodically replace the adsorbent and sealing components to ensure the equipment's performance.
3. Calibration: Regularly calibrate the equipment to guarantee the accuracy of the flow rate and pressure.Safe Operation:
1. Protective Gear: Wear protective eyewear, gloves, etc. during operation to avoid injury from chemical reagents.
2. Adequate Ventilation: Operate in a well-ventilated environment to prevent the accumulation of harmful gases.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation