Glass Bead Sterilizer,Dry Heat Sterilizer
Glass Bead Sterilizer,Dry Heat Sterilizer
RGBS-A
Brand:
RUISCI
-
Click to select
- RGBS-A-08,ɸ40*80mm
- RGBS-A-14,ɸ40*140mm
Inventory
336
隐藏域元素占位
Overview
The glass bead sterilizer is a kind of equipment that implements sterilization through high-temperature glass beads. It heats the glass beads to approximately 250℃ and, by virtue of the principle of high-temperature conduction, rapidly sterilizes the surface of instruments. Commonly utilized for the sterilization treatment of small medical devices and tools, it boasts the merits of straightforward operation, rapid sterilization speed, and no chemical residue. It is extensively applied in domains such as healthcare and laboratories, and is particularly suitable for sterilizing instruments that are intolerant to damp heat.
Features
1. The real-time temperature value is displayed, and the countdown is shown.
2. The maximum temperature within the container containing high-temperature sterilization beads can reach 300℃.
3. A portion of glass beads with a diameter of 3.0mm is randomly configured.
4. It has a small volume, light weight, simple operation, and a long service life.
5. The stainless steel inner container is equipped with high-performance heating components, a high-precision temperature controller, and a built-in over-temperature protection device.
Technical data

1. Inspect the equipment: Before usage, ensure that the appearance of the equipment, power cord, temperature controller and other components are in normal condition, and that there are sufficient glass beads without any foreign substances.
2. Control the temperature: Make sure the temperature is set within the recommended range (approximately 250℃), and operate after the preheating is stable.
3. Prepare the instruments: The instruments need to be clean and dry, with no residual liquid, and the material should be resistant to high temperatures.
4. Insert the instruments: The insertion should be rapid with an appropriate depth, avoiding touching the bottom of the container.
5. Control the time: Control the sterilization time based on the size of the instruments (10 - 15 seconds), avoiding either too short or too long durations.
6. Remove the instruments: Use tools to extract them, avoiding direct contact with the high-temperature instruments to prevent scalding.
7. Safety protection: Wear protective gloves and goggles during the operation to avoid scalding.
8. Cleaning and maintenance: Clean the surface of the glass beads after usage, and regularly inspect and replace the glass beads.
9. Environmental requirements: Place it on a stable countertop with good ventilation and away from flammable items.
10. Emergency situations: Immediately cut off the power supply when the equipment is abnormal.
keyword:
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Glass Bead Sterilizer,Dry Heat Sterilizer
- Subtitle: Glass Bead Sterilizer,Dry Heat Sterilizer
- Model: RGBS-A
- 全部型号: RGBS-A-08,RGBS-A-14
The glass bead sterilizer is a kind of equipment that implements sterilization through high-temperature glass beads.
The glass bead sterilizer is a kind of equipment that implements sterilization through high-temperature glass beads. It heats the glass beads to approximately 250℃ and, by virtue of the principle of high-temperature conduction, rapidly sterilizes the surface of instruments. Commonly utilized for the sterilization treatment of small medical devices and tools, it boasts the merits of straightforward operation, rapid sterilization speed, and no chemical residue. It is extensively applied in domains such as healthcare and laboratories, and is particularly suitable for sterilizing instruments that are intolerant to damp heat.
-
1. The real-time temperature value is displayed, and the countdown is shown.
2. The maximum temperature within the container containing high-temperature sterilization beads can reach 300℃.
3. A portion of glass beads with a diameter of 3.0mm is randomly configured.
4. It has a small volume, light weight, simple operation, and a long service life.
5. The stainless steel inner container is equipped with high-performance heating components, a high-precision temperature controller, and a built-in over-temperature protection device. -

1. Inspect the equipment: Before usage, ensure that the appearance of the equipment, power cord, temperature controller and other components are in normal condition, and that there are sufficient glass beads without any foreign substances.
2. Control the temperature: Make sure the temperature is set within the recommended range (approximately 250℃), and operate after the preheating is stable.
3. Prepare the instruments: The instruments need to be clean and dry, with no residual liquid, and the material should be resistant to high temperatures.
4. Insert the instruments: The insertion should be rapid with an appropriate depth, avoiding touching the bottom of the container.
5. Control the time: Control the sterilization time based on the size of the instruments (10 - 15 seconds), avoiding either too short or too long durations.
6. Remove the instruments: Use tools to extract them, avoiding direct contact with the high-temperature instruments to prevent scalding.
7. Safety protection: Wear protective gloves and goggles during the operation to avoid scalding.
8. Cleaning and maintenance: Clean the surface of the glass beads after usage, and regularly inspect and replace the glass beads.
9. Environmental requirements: Place it on a stable countertop with good ventilation and away from flammable items.
10. Emergency situations: Immediately cut off the power supply when the equipment is abnormal.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation