Overview
The UV Ozone Cleaner utilizes ultraviolet rays emitted by ultraviolet lamps to generate ozone and atomic oxygen, which then eliminate organic pollutants on the surface of objects through photosensitized oxidation reactions.It possesses advantages such as high efficiency, non-contact, environmental protection, and no residue. It is applicable to fields like electronics, optics, semiconductors, etc., and is simple to operate.
Features
1. Controlled by a 5-inch color touchscreen, it can autonomously set the process parameters such as operating time, heating temperature, gas path flow rate and so on.
2. The integrated heating and lifting sample stage has a lifting stroke of 50mm, facilitating the adjustment of the distance between the sample and the UV lamp.
3. The sample stage is equipped with constant temperature control, featuring intelligent PID temperature regulation. The setting range is from RT to 200℃, and the temperature control accuracy is ±1℃.
4. The flow rate, heating, and UV lamp can be automatically and independently controlled for activation and deactivation. The processing can be manually interrupted.
5. The combined processing mode allows for free selection: whether to enable the heating function of the sample stage and open the oxygen supply gas path.
6. The cleaning parameter settings are automatically stored and historical records are generated to prevent the oblivion of experimental data.
7. It is safe and reliable. During the equipment operation, when the cover of the cleaning chamber is opened, the UV lamp will automatically turn off, and a pop-up window will prompt to avoid UV damage.
8. Standardly equipped with digital flow rate display (capable of being connected to oxygen or ozone), the gas supply flow rate of the gas path can be adjusted.
9. The upper-mounted sample stage and the top-flip cover design facilitate the placement and removal of samples, with simple and rapid operation.
10. With dual-wave UV light sources at wavelengths of 254nm and 185nm, the lamp tube has a lifespan of approximately 8,000 hours. It is equipped with a UV reflector to homogenize the sample irradiation.
11. One-click operation is available to reduce work intensity.
Technical data

Before Operation:
1. Inspect the appearance and connections of the equipment to ensure that the power cord is intact, and has a reliable grounding.
2. Put on protective equipment such as long-sleeved clothing, gloves, and anti-ultraviolet glasses, and avoid looking directly at the ultraviolet lamp.
3. Place the items to be cleaned steadily on the cleaning platform to ensure no obstructions.
During Operation:
1. Set the parameters rationally in accordance with the cleaning requirements and avoid frequent power-on and power-off operations.
2. Ensure adequate ventilation of the equipment to prevent the accumulation of ozone.
3. Monitor the operating status of the equipment. In case of any anomalies, stop the machine immediately for inspection.
After Operation:
1. After the cleaning is completed, wait for 5 to 10 minutes and take out the items after the ozone has dissipated.
2. Shut down the equipment and disconnect the power supply.
3. Regularly clean and maintain the equipment to guarantee its long-term stable operation.
keyword:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: UV Ozone Cleaner
- Subtitle: UV Ozone Cleaner
- Model: RUVZ-A
- 全部型号: RUVZ-A-10,RUVZ-A-12,RUVZ-A-15
The UV Ozone Cleaner utilizes ultraviolet rays emitted by ultraviolet lamps to generate ozone and atomic oxygen.
The UV Ozone Cleaner utilizes ultraviolet rays emitted by ultraviolet lamps to generate ozone and atomic oxygen, which then eliminate organic pollutants on the surface of objects through photosensitized oxidation reactions.It possesses advantages such as high efficiency, non-contact, environmental protection, and no residue. It is applicable to fields like electronics, optics, semiconductors, etc., and is simple to operate.
-
1. Controlled by a 5-inch color touchscreen, it can autonomously set the process parameters such as operating time, heating temperature, gas path flow rate and so on.
2. The integrated heating and lifting sample stage has a lifting stroke of 50mm, facilitating the adjustment of the distance between the sample and the UV lamp.
3. The sample stage is equipped with constant temperature control, featuring intelligent PID temperature regulation. The setting range is from RT to 200℃, and the temperature control accuracy is ±1℃.
4. The flow rate, heating, and UV lamp can be automatically and independently controlled for activation and deactivation. The processing can be manually interrupted.
5. The combined processing mode allows for free selection: whether to enable the heating function of the sample stage and open the oxygen supply gas path.
6. The cleaning parameter settings are automatically stored and historical records are generated to prevent the oblivion of experimental data.
7. It is safe and reliable. During the equipment operation, when the cover of the cleaning chamber is opened, the UV lamp will automatically turn off, and a pop-up window will prompt to avoid UV damage.
8. Standardly equipped with digital flow rate display (capable of being connected to oxygen or ozone), the gas supply flow rate of the gas path can be adjusted.
9. The upper-mounted sample stage and the top-flip cover design facilitate the placement and removal of samples, with simple and rapid operation.
10. With dual-wave UV light sources at wavelengths of 254nm and 185nm, the lamp tube has a lifespan of approximately 8,000 hours. It is equipped with a UV reflector to homogenize the sample irradiation.
11. One-click operation is available to reduce work intensity. -

Before Operation:
1. Inspect the appearance and connections of the equipment to ensure that the power cord is intact, and has a reliable grounding.
2. Put on protective equipment such as long-sleeved clothing, gloves, and anti-ultraviolet glasses, and avoid looking directly at the ultraviolet lamp.
3. Place the items to be cleaned steadily on the cleaning platform to ensure no obstructions.During Operation:
1. Set the parameters rationally in accordance with the cleaning requirements and avoid frequent power-on and power-off operations.
2. Ensure adequate ventilation of the equipment to prevent the accumulation of ozone.
3. Monitor the operating status of the equipment. In case of any anomalies, stop the machine immediately for inspection.After Operation:
1. After the cleaning is completed, wait for 5 to 10 minutes and take out the items after the ozone has dissipated.
2. Shut down the equipment and disconnect the power supply.
3. Regularly clean and maintain the equipment to guarantee its long-term stable operation.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation