Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Halogen Rapid Moisture Analyzer

Halogen Rapid Moisture Analyzer

RMAN-A


RUISCI

Brand:

RUISCI


USD

371

Untaxed

EXW factory


  • Click to select
    • RMAN-A-01,50g,±0.005g
    • RMAN-A-02,50g,Highly,±0.005g
    • RMAN-A-03,50g,Highly,±0.002g
    • RMAN-A-04,110g,Highly,±0.001g
Quantity
-
+

Inventory

672

隐藏域元素占位


Halogen Moisture Analyzer is a sophisticated instrument that employs halogen lamps as the heating source and is extensively utilized in the determination of moisture content in multiple domains such as food, chemical, pharmaceutical, and agricultural.


1. The high-efficiency halogen lamp features rapid heating, time conservation and a longer service life.
2. The detachable aluminum alloy heating chamber enables rapid heat transfer, enhances efficiency, is corrosion-resistant and easy to clean.
3. The 5-inch intelligent touchscreen display allows for real-time dynamic analysis of time and moisture loss rate curves, with multiple parameters directly accessible.
4. The double-handle silent opening of the heating chamber door reduces the influence on weighing.
5. There are 15 sets of large-capacity named data storage.
6. The low-noise micro fan effectively protects the main unit from the influence of heat sources.

Technical data

Environmental Conditions:
1. The working space should be maintained clean and well-ventilated.
2. The instrument should be placed on a horizontal and stable workbench.
3. Locations with severe temperature fluctuations, excessive humidity, poor air flow, vibration, electromagnetic fields, intense heat or direct sunlight should be avoided as much as possible.
4. It is prohibited to use in areas with explosive hazards.
5. Prolonged use in environments with high humidity or high dust concentrations is not allowed.
Precautions:
1. Before usage, adjust the level using the bottom adjustment foot screws to ensure the bubble in the level indicator is centered within the circle.
2. To obtain the optimal test results, it is recommended to power on the device for at least 30 minutes before operation.
3. Do not manipulate the temperature calibration without permission, as this may reset the temperature value to zero, resulting in the need for factory repair.
4. When dealing with toxic and volatile media, be sure to carry out the operation in an appropriate fume hood.
5. When handling flammable and explosive media, pay attention to maintaining low temperatures and dry conditions.
6. When handling corrosive media, be cautious and measure a small amount of the substance for testing.
7. In cases of frequent use of the moisture analyzer, it should be kept continuously powered on to reduce the preheating time and keep it in a relatively stable state.
8. The moisture analyzer should be kept clean. Be vigilant to prevent dust and other substances from penetrating into it. The weighing pan and the casing should be frequently wiped clean with a mild detergent and a soft cloth. Do not use strong solvents such as alcohol or gasoline for cleaning. Moreover, the moisture analyzer should not be placed in an environment with corrosive gases.
9. Based on the usage intensity of the moisture analyzer, periodic inspections and calibrations should be conducted.
10.Do not manipulate the temperature calibration without authorization, as this may reset the temperature value to zero, leading to the need for factory repair.
11.When the product is not in use for an extended period, disconnect the power of the instrument, cover it with a dust bag, and store it in a dry, clean, normal-temperature and stable environment.
12.Before reactivating the machine after a prolonged period of non-use, it is necessary to check whether all functions are normal before conducting experiments.

keyword:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Halogen Rapid Moisture Analyzer
    • Subtitle: Halogen Rapid Moisture Analyzer
    • Model: RMAN-A
    • 全部型号: RMAN-A-01,RMAN-A-02,RMAN-A-03,RMAN-A-04

    Halogen Moisture Analyzer is a sophisticated instrument that employs halogen lamps as the heating source and is extensively utilized in the determination of moisture content in multiple domains such as food, chemical, pharmaceutical, and agricultural.

    Halogen Moisture Analyzer is a sophisticated instrument that employs halogen lamps as the heating source and is extensively utilized in the determination of moisture content in multiple domains such as food, chemical, pharmaceutical, and agricultural.

  • 1. The high-efficiency halogen lamp features rapid heating, time conservation and a longer service life.
    2. The detachable aluminum alloy heating chamber enables rapid heat transfer, enhances efficiency, is corrosion-resistant and easy to clean.
    3. The 5-inch intelligent touchscreen display allows for real-time dynamic analysis of time and moisture loss rate curves, with multiple parameters directly accessible.
    4. The double-handle silent opening of the heating chamber door reduces the influence on weighing.
    5. There are 15 sets of large-capacity named data storage.
    6. The low-noise micro fan effectively protects the main unit from the influence of heat sources.

  • Environmental Conditions:
    1. The working space should be maintained clean and well-ventilated.
    2. The instrument should be placed on a horizontal and stable workbench.
    3. Locations with severe temperature fluctuations, excessive humidity, poor air flow, vibration, electromagnetic fields, intense heat or direct sunlight should be avoided as much as possible.
    4. It is prohibited to use in areas with explosive hazards.
    5. Prolonged use in environments with high humidity or high dust concentrations is not allowed.
    Precautions:
    1. Before usage, adjust the level using the bottom adjustment foot screws to ensure the bubble in the level indicator is centered within the circle.
    2. To obtain the optimal test results, it is recommended to power on the device for at least 30 minutes before operation.
    3. Do not manipulate the temperature calibration without permission, as this may reset the temperature value to zero, resulting in the need for factory repair.
    4. When dealing with toxic and volatile media, be sure to carry out the operation in an appropriate fume hood.
    5. When handling flammable and explosive media, pay attention to maintaining low temperatures and dry conditions.
    6. When handling corrosive media, be cautious and measure a small amount of the substance for testing.
    7. In cases of frequent use of the moisture analyzer, it should be kept continuously powered on to reduce the preheating time and keep it in a relatively stable state.
    8. The moisture analyzer should be kept clean. Be vigilant to prevent dust and other substances from penetrating into it. The weighing pan and the casing should be frequently wiped clean with a mild detergent and a soft cloth. Do not use strong solvents such as alcohol or gasoline for cleaning. Moreover, the moisture analyzer should not be placed in an environment with corrosive gases.
    9. Based on the usage intensity of the moisture analyzer, periodic inspections and calibrations should be conducted.
    10.Do not manipulate the temperature calibration without authorization, as this may reset the temperature value to zero, leading to the need for factory repair.
    11.When the product is not in use for an extended period, disconnect the power of the instrument, cover it with a dust bag, and store it in a dry, clean, normal-temperature and stable environment.
    12.Before reactivating the machine after a prolonged period of non-use, it is necessary to check whether all functions are normal before conducting experiments.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Weighing Pan(For The Moisture Analyzer)

Price:

7

USD

Delivery:

30 Days


Weighing Pan is typically employed in laboratories for operations such as sample subdivision, heating, and weighing determination.

Electronic Scale

Price:

47

USD

Delivery:

30 Days


Electronic scales predominantly achieve precise weighing by virtue of the principle of electromagnetic force balance or strain gauge sensing technology.

Vortex Mixer

Price:

60

USD

Delivery:

30 Days


The Vortex Mixer is a device that is extensively utilized in laboratories, primarily employed for blending and oscillating biological samples, chemical reagents, and the like.

Oscillating Incubator

Price:

1375

USD

Delivery:

30 Days


The Oscillating Incubator is a kind of laboratory equipment, which is mainly utilized to offer suitable growth environments for biological samples like cells and microorganisms.

Ball Milling Jar,2

Price:

91

USD

Delivery:

30 Days


The ball milling jar is one of the core components of the planetary ball mill.

Online consultation


Name:

Submit