Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

High And Low Temperature Test Chamber,1

High And Low Temperature Test Chamber

RHN-C,RHN-A


RUISCI

Brand:

RUISCI


USD

577

Untaxed

EXW factory


  • Click to select
    • RHN-C-01,-40~100℃,High And Low
    • RHN-C-02,-50~100℃,High And Low
    • RHN-A-01,-25℃,Low,Vertical,80L
    • RHN-A-02,-40℃,Low,Vertical,80L
    • RHN-A-03,-50℃,Low,Vertical,80L
    • RHN-A-04,-60℃,Low,Vertical,80L
    • RHN-A-05,-40℃,Low,Vertical,80L
    • RHN-A-06,-50℃,Low,Vertical,80L
    • RHN-A-07,-60℃,Low,Vertical,80L
    • RHN-A-08,-25℃,Low,Vertical,200L
    • RHN-A-09,-40℃,Low,Vertical,200L
    • RHN-A-10,-50℃,Low,Vertical,200L
    • RHN-A-11,-60℃,Low,Vertical,200L
    • RHN-A-12,-40℃,Low,Vertical,200L
    • RHN-A-13,-50℃,Low,Vertical,200L
Quantity
-
+

Inventory

1845

隐藏域元素占位


The High And Low Temperature Test Chamber is a dedicated apparatus employed for simulating experimental environments, aimed at replicating diverse temperature conditions to assess the performance, reliability, and stability of materials, products, or components in high and low temperature circumstances. It exerts a significant role in domains such as scientific research, quality inspection, product development, and others.


Characteristics:
1. The laboratory high and low temperature test chamber is furnished with a highly accurate temperature control system, enabling precise control of the temperature within the chamber.
2. The test chamber is provided with an emergency stop button, enabling the operator to promptly cease the operation of the equipment in the event of an emergent situation to guarantee safety.
3. The sealing performance of the chamber is outstanding, capable of preventing the ingress of external air or the leakage of internal hot or cold air, thus ensuring the stability of the experimental environment.
4. The inner liner of the test chamber is fabricated from stainless steel or aluminum plate, not only being corrosion-resistant and heat-resistant but also being facile for cleaning.

Technical data

Precautions:
1. Before connecting to the power supply, ensure that the switch on the control panel is in the off state.
2. When it is necessary to halt the operation, first turn off the power switch on the control panel. Do not disconnect the power directly.
3. In the event of a sudden power outage, switch off the power switch of the test chamber. If restart is required, wait for at least 30 minutes before initiating the startup. An immediate startup after a power failure may impact the lifespan of the compressor and could even lead to its damage.
4. When transporting, strive to maintain horizontality, with the tilt not exceeding 45 degrees. Placing it in a well-ventilated and dry location is conducive to heat dissipation of the machine and enhances working efficiency.
5. When placing specimens, leave a certain space between specimens and between specimens and the inner liner to guarantee the flow of cold air and uniform cooling.
6. For objects with high humidity and those prone to moisture loss, it is advisable to enclose them in a sealed bag before placement to prevent moisture release. Moisture release may cause frosting within the working chamber, affecting the cooling process.
7. It is strictly prohibited to place volatile and flammable gases or liquids in the chamber, such as strong acids, strong alkalis, gasoline, alcohol, and the like.
8. It is not recommended to place an excessive number of specimens at once to avoid a sluggish temperature drop and failure to meet the test requirements.
9. After usage, disconnect the power supply, remove the test specimens, open the door of the freezer to allow for natural temperature rise. Once the frost layer melts, drain the water and wipe it dry using a soft cloth.

keyword:

Low Temperature Chamber

environmental chamber

Test chamber

Low Temperature Test Chamber

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: High And Low Temperature Test Chamber,1
    • Subtitle: High And Low Temperature Test Chamber
    • Model: RHN-C,RHN-A
    • 全部型号: environmental chamber, Low Ttemperature Test Chamber,Low Temperature Chamber,RHN-C-01,RHN-C-02,RHN-A-01,RHN-A-02,RHN-A-03,RHN-A-04,RHN-A-05,RHN-A-06,RHN-A-07,RHN-A-08,RHN-A-09,RHN-A-10,RHN-A-11,RHN-A-12,RHN-A-13

    The High And Low Temperature Test Chamber is a dedicated apparatus employed for simulating experimental environments, aimed at replicating diverse temperature conditions to assess the performance, reliability, and stability of materials, products, or components in high and low temperature circumstances.

    The High And Low Temperature Test Chamber is a dedicated apparatus employed for simulating experimental environments, aimed at replicating diverse temperature conditions to assess the performance, reliability, and stability of materials, products, or components in high and low temperature circumstances. It exerts a significant role in domains such as scientific research, quality inspection, product development, and others.

  • Characteristics:
    1. The laboratory high and low temperature test chamber is furnished with a highly accurate temperature control system, enabling precise control of the temperature within the chamber.
    2. The test chamber is provided with an emergency stop button, enabling the operator to promptly cease the operation of the equipment in the event of an emergent situation to guarantee safety.
    3. The sealing performance of the chamber is outstanding, capable of preventing the ingress of external air or the leakage of internal hot or cold air, thus ensuring the stability of the experimental environment.
    4. The inner liner of the test chamber is fabricated from stainless steel or aluminum plate, not only being corrosion-resistant and heat-resistant but also being facile for cleaning.

  • Precautions:
    1. Before connecting to the power supply, ensure that the switch on the control panel is in the off state.
    2. When it is necessary to halt the operation, first turn off the power switch on the control panel. Do not disconnect the power directly.
    3. In the event of a sudden power outage, switch off the power switch of the test chamber. If restart is required, wait for at least 30 minutes before initiating the startup. An immediate startup after a power failure may impact the lifespan of the compressor and could even lead to its damage.
    4. When transporting, strive to maintain horizontality, with the tilt not exceeding 45 degrees. Placing it in a well-ventilated and dry location is conducive to heat dissipation of the machine and enhances working efficiency.
    5. When placing specimens, leave a certain space between specimens and between specimens and the inner liner to guarantee the flow of cold air and uniform cooling.
    6. For objects with high humidity and those prone to moisture loss, it is advisable to enclose them in a sealed bag before placement to prevent moisture release. Moisture release may cause frosting within the working chamber, affecting the cooling process.
    7. It is strictly prohibited to place volatile and flammable gases or liquids in the chamber, such as strong acids, strong alkalis, gasoline, alcohol, and the like.
    8. It is not recommended to place an excessive number of specimens at once to avoid a sluggish temperature drop and failure to meet the test requirements.
    9. After usage, disconnect the power supply, remove the test specimens, open the door of the freezer to allow for natural temperature rise. Once the frost layer melts, drain the water and wipe it dry using a soft cloth.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Thermohygrometer

Price:

6

USD

Delivery:

7 Days


A thermohygrometer is an instrument employed for measuring and documenting the temperature and humidity within a laboratory setting.

Small Laboratory Lifting Platform

Price:

8

USD

Delivery:

7 Days


The Small Laboratory Lifting Platform is an auxiliary device employed in laboratories for adjusting the height of equipment or items.

Reagent Rack,2

Price:

93

USD

Delivery:

7 Days


Reagent rack is a support utilized in laboratories for placing laboratory supplies such as glassware, test tubes, and reagents.

Rotary Swivel Chair

Price:

20

USD

Delivery:

30 Days


The rotary swivel chair is one of the indispensable appliances in the laboratory setting.

High And Low Temperature Test Chamber,2

Price:

450

USD

Delivery:

30 Days


The High And Low Temperature Test Chamber is a dedicated apparatus employed for simulating experimental environments, aimed at replicating diverse temperature conditions to assess the performance, reliability, and stability of materials, products, or components in high and low temperature circumstances.

Online consultation


Name:

Submit