Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Liquid Liquid Extraction Instrument

Liquid Liquid Extraction Instrument

RQU-A


RUISCI

Brand:

RUISCI


USD

3763

Untaxed

EXW factory


  • Click to select
    • RQU-A-01,Automatically
    • RQU-A-01A,Fully Automatic
Quantity
-
+

Inventory

194

隐藏域元素占位


Liquid Liquid Extraction Instrument employs a novel closed, silent and clean air internal circulation oscillation principle and a bidirectional gas-liquid mixing technique. It is utilized for the pre-treatment of liquid-liquid extraction in laboratory water quality testing for items such as oil, volatile phenols, and anions in water. The device displays and sets numerous extraction parameters via a large liquid crystal touchscreen to fulfill the extraction requirements of diverse samples. During the experimental process, no manual supervision is necessary. The equipment realizes functions like automatic extraction, automatic degassing, automatic collection, automatic drainage, and automatic cleaning. The liquid-liquid extraction setup is extensively applied in fields such as petrochemical, sewage treatment, medical and health care, environmental monitoring, steel and power plants, scientific research institutions, etc.


1. Swift extraction speed: Multiple samples can be extracted concurrently within 3 minutes.
2. Adjustable flow duration: Boasting a high degree of automation, enabling simultaneous extraction and degassing.
3. Large LCD touchscreen: A 7-inch large LCD touchscreen allows for one-click operation, making the system straightforward and convenient.
4. Multi-channel extraction unit: The 6-position operating system can independently accomplish the extraction of 6 groups of samples.
5. Independent sample control: Supports the utilization of various specification extraction bottles (250/500/1000ml). The extraction time intervals and cycles can be independently set at will.

Technical data

Working Environment Conditions:
1. Power Supply: 220V, 300W
2. Placement: On a stable and horizontal tabletop.
3. Ventilation: Adequate ventilation, preferably within a fume hood.
4. Fire Prevention: Stay away from fire sources and heat sources.
5. Cleanliness: Keep the environment tidy and free from dust and moisture.
6. Anti-Corrosion: Absence of corrosive gases.
7. Noise Reduction: Low-noise environment.

Precautions:
1. Wear Protective Gear: Wear protective glasses and gloves during operation.
2. Inspect the Instrument: Check if the instrument is intact before usage.
3. Maintain Cleanliness: Ensure both the interior and exterior of the instrument are clean.
4. Correct Installation: Install components and ensure tight sealing.
5. Check the Gas Source: Ensure the gas source is stable and clean.
6. Check the Power Supply: Ensure the power supply complies with requirements.
7. Avoid Overloading: Do not exceed the maximum capacity of the instrument.
8. Control Temperature: Ensure the ambient temperature is suitable.
9. Control Humidity: Prevent the instrument from getting damp.
10. Avoid Vibration: Place on a stable tabletop.
11. Avoid Corrosion: Absence of corrosive gases.
12. Keep Away from Fire Sources: When using flammable solvents, stay away from fire sources.
13. Be Mindful of Ventilation: Operate in a well-ventilated environment.
14. Regular Maintenance: Regularly inspect and maintain the instrument.

keyword:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Liquid Liquid Extraction Instrument
    • Subtitle: Liquid Liquid Extraction Instrument
    • Model: RQU-A
    • 全部型号: RQU-A-01,RQU-A-01A

    Liquid Liquid Extraction Instrument employs a novel closed, silent and clean air internal circulation oscillation principle and a bidirectional gas-liquid mixing technique.

    Liquid Liquid Extraction Instrument employs a novel closed, silent and clean air internal circulation oscillation principle and a bidirectional gas-liquid mixing technique. It is utilized for the pre-treatment of liquid-liquid extraction in laboratory water quality testing for items such as oil, volatile phenols, and anions in water. The device displays and sets numerous extraction parameters via a large liquid crystal touchscreen to fulfill the extraction requirements of diverse samples. During the experimental process, no manual supervision is necessary. The equipment realizes functions like automatic extraction, automatic degassing, automatic collection, automatic drainage, and automatic cleaning. The liquid-liquid extraction setup is extensively applied in fields such as petrochemical, sewage treatment, medical and health care, environmental monitoring, steel and power plants, scientific research institutions, etc.

  • 1. Swift extraction speed: Multiple samples can be extracted concurrently within 3 minutes.
    2. Adjustable flow duration: Boasting a high degree of automation, enabling simultaneous extraction and degassing.
    3. Large LCD touchscreen: A 7-inch large LCD touchscreen allows for one-click operation, making the system straightforward and convenient.
    4. Multi-channel extraction unit: The 6-position operating system can independently accomplish the extraction of 6 groups of samples.
    5. Independent sample control: Supports the utilization of various specification extraction bottles (250/500/1000ml). The extraction time intervals and cycles can be independently set at will.

  • Working Environment Conditions:
    1. Power Supply: 220V, 300W
    2. Placement: On a stable and horizontal tabletop.
    3. Ventilation: Adequate ventilation, preferably within a fume hood.
    4. Fire Prevention: Stay away from fire sources and heat sources.
    5. Cleanliness: Keep the environment tidy and free from dust and moisture.
    6. Anti-Corrosion: Absence of corrosive gases.
    7. Noise Reduction: Low-noise environment.

    Precautions:
    1. Wear Protective Gear: Wear protective glasses and gloves during operation.
    2. Inspect the Instrument: Check if the instrument is intact before usage.
    3. Maintain Cleanliness: Ensure both the interior and exterior of the instrument are clean.
    4. Correct Installation: Install components and ensure tight sealing.
    5. Check the Gas Source: Ensure the gas source is stable and clean.
    6. Check the Power Supply: Ensure the power supply complies with requirements.
    7. Avoid Overloading: Do not exceed the maximum capacity of the instrument.
    8. Control Temperature: Ensure the ambient temperature is suitable.
    9. Control Humidity: Prevent the instrument from getting damp.
    10. Avoid Vibration: Place on a stable tabletop.
    11. Avoid Corrosion: Absence of corrosive gases.
    12. Keep Away from Fire Sources: When using flammable solvents, stay away from fire sources.
    13. Be Mindful of Ventilation: Operate in a well-ventilated environment.
    14. Regular Maintenance: Regularly inspect and maintain the instrument.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Soxhlet Extraction Apparatus

Price:

288

USD

Delivery:

30 Days


The Soxhlet extractor is a frequently employed extraction apparatus in laboratories. It is composed of three components: the extraction flask, the extraction tube, and the condenser.

Ion Sputter Coater

Price:

125

USD

Delivery:

30 Days


Ion Sputter Coater is a precise equipment for surface treatment. Through ion bombardment of the target material, it realizes uniform coating of materials.

Instrument Cart,1

Price:

46

USD

Delivery:

7 Days


The instrument cart, specifically engineered for laboratory settings, serves as a mobile utility for transporting, storing, and operating diverse laboratory apparatuses and devices.

Solid Phase Extraction(SPE)

Price:

280

USD

Delivery:

30 Days


Solid Phase Extraction (SPE) serves to separate and concentrate the target compounds from liquid samples.

Glass Condenser,Double Standard Ground Joint,Spherical

Price:

6

USD

Delivery:

7 Days


Glass Condenseris a frequently employed glass apparatus in laboratories, primarily utilized for experimental operations such as distillation and reflux. It is fabricated from high borosilicate glass and possesses the characteristics of high-temperature resistance and corrosion resistance.

Online consultation


Name: