Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Bath Oscillator

Water Bath Oscillato,Air Bath Oscillator

RWA-B


RUISCI

Brand:

RUISCI


USD

468

Untaxed

EXW factory


  • Click to select
    • RWA-B-01,Circumvolution Reciprocation,Water Bath
    • RWA-B-02,Circumvolution,Water Bath
    • RWA-B-03,Reciprocation,Water Bath
    • RWA-B-04,Circumvolution,Air Bath
    • RWA-B-05,Reciprocation,Air Bath
    • RWA-B-06,Circumvolution Reciprocation,Air Bath
    • RWA-B-01A,Circumvolution Reciprocation,Water Bath
    • RWA-B-02A,,Circumvolution,Water Bath
    • RWA-B-03A,Reciprocation,Water Bath
    • RWA-B-04A,Circumvolution,Air Bath
    • RWA-B-05A,Reciprocation,Air Bath
    • RWA-B-06A,Circumvolution Reciprocation,Air Bath
Quantity
-
+

Inventory

1308

隐藏域元素占位


The water bath oscillator is a biochemical instrument that integrates a constant-temperature water bath and an oscillator. It controls the water temperature within the preset range via heating tubes and enables samples to undergo reciprocating or circular oscillations in the water bath. It is frequently employed for sample cultivation and reactions in biological and biochemical experiments.

The air bath oscillator is a biochemical instrument that combines a constant-temperature incubator and an oscillator. It heats the air to the set temperature through heating elements, allowing samples to oscillate in a water-free environment. It is suitable for samples that are sensitive to humidity and is commonly utilized in experiments such as microbiology and cell culture.


1. The double-layer stainless steel spring is extensible and more stable: It is applicable to containers of diverse capacities and can be equipped with multiple reagent bottles, catering to different experimental demands.
2. Upgraded 304 stainless steel with superior anti-rust property: The water tank, cover, and support are all fabricated from 304 stainless steel.
3. Dual digital display configuration: Intuitively and clearly presenting temperature, rotational speed, and time.
4. PT100 sensor: The PT100 temperature sensor enables more precise temperature control.
5. Silicone drain pipe: Unscrewing it enables drainage simply and conveniently, without the need for movement.

Technical data

Working Environment Conditions:
Water Bath Oscillator
1. Temperature: The temperature is controlled within the range of 5°C to 100°C.
2. Placement Environment: It should be placed on a level workbench, avoiding direct sunlight, and there should be adequate space around it for heat dissipation and operation.
3. Water Quality: Distilled or deionized water should be utilized in the water bath tank to prevent scale formation and corrosion.
Air Bath Oscillator
1. Temperature: The temperature is controlled within 5°C to 50°C.
2. Placement Environment: It should be placed on a flat and stable countertop, avoiding direct sunlight and strong electromagnetic interference.
3. Ventilation: Excellent ventilation conditions are necessary to ensure the equipment's heat dissipation and the accuracy of temperature control.

Precautions:
Water Bath Oscillator
1. Water Level Inspection: Before usage, it is necessary to inspect whether the water level in the water bath tank is appropriate, ensuring that the water level is higher than the heating tubes to avoid dry burning and damage to the equipment.
2. Water Quality Maintenance: Regularly replace the water in the water bath tank to prevent the accumulation of scale, which might affect the heating effect and the equipment's service life.
3. Sample Placement: Samples should be placed on a dedicated sample rack, avoiding direct contact with the wall of the water bath tank to avoid influencing temperature uniformity.
4. Temperature Control: When setting the temperature, it should be precisely set in accordance with the experimental requirements to avoid temperatures that are too high or too low, which could impact the samples.
5. Cleaning and Maintenance: Promptly clean up any debris and residues in the water bath tank after usage and regularly clean and disinfect the equipment.
6. Safety Precautions: Wear protective gloves during operation to avoid scalding from hot water. After usage, disconnect the power supply to ensure safety.

Air Bath Oscillator
1. Temperature Calibration: Regularly inspect the accuracy of the temperature sensor to ensure the temperature is controlled within the preset range.
2. Sample Fixation: Samples should be firmly placed on the sample rack to prevent shaking or dropping during oscillation.
3. Ventilation Requirements: Ensure there is sufficient space around the equipment to guarantee good ventilation and prevent overheating due to poor heat dissipation.
4. Cleaning and Maintenance: Regularly clean the dust and debris inside the equipment to maintain its cleanliness and good operational status.
5. Power Check: Before usage, inspect whether the power cord and socket are normal to avoid equipment damage due to power issues.
6. Safe Operation: During the equipment's operation, avoid opening the door to prevent influencing temperature uniformity and experimental results. After usage, disconnect the power supply and clean the interior of the equipment.

keyword:

Water Bath Oscillato

Air Bath Oscillator

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Bath Oscillator
    • Subtitle: Water Bath Oscillato,Air Bath Oscillator
    • Model: RWA-B
    • 全部型号: Water Bath Oscillato,Air Bath Oscillator,RWA-B-01,RWA-B-02,RWA-B-03,RWA-B-04,RWA-B-05,RWA-B-06,RWA-B-01A,RWA-B-02A,RWA-B-03A,RWA-B-04A,RWA-B-05A,RWA-B-06A

    The water bath oscillator is a biochemical instrument that integrates a constant-temperature water bath and an oscillator. The air bath oscillator is a biochemical instrument that combines a constant-temperature incubator and an oscillator.

    The water bath oscillator is a biochemical instrument that integrates a constant-temperature water bath and an oscillator. It controls the water temperature within the preset range via heating tubes and enables samples to undergo reciprocating or circular oscillations in the water bath. It is frequently employed for sample cultivation and reactions in biological and biochemical experiments.

    The air bath oscillator is a biochemical instrument that combines a constant-temperature incubator and an oscillator. It heats the air to the set temperature through heating elements, allowing samples to oscillate in a water-free environment. It is suitable for samples that are sensitive to humidity and is commonly utilized in experiments such as microbiology and cell culture.

  • 1. The double-layer stainless steel spring is extensible and more stable: It is applicable to containers of diverse capacities and can be equipped with multiple reagent bottles, catering to different experimental demands.
    2. Upgraded 304 stainless steel with superior anti-rust property: The water tank, cover, and support are all fabricated from 304 stainless steel.
    3. Dual digital display configuration: Intuitively and clearly presenting temperature, rotational speed, and time.
    4. PT100 sensor: The PT100 temperature sensor enables more precise temperature control.
    5. Silicone drain pipe: Unscrewing it enables drainage simply and conveniently, without the need for movement.

  • Working Environment Conditions:
    Water Bath Oscillator
    1. Temperature: The temperature is controlled within the range of 5°C to 100°C.
    2. Placement Environment: It should be placed on a level workbench, avoiding direct sunlight, and there should be adequate space around it for heat dissipation and operation.
    3. Water Quality: Distilled or deionized water should be utilized in the water bath tank to prevent scale formation and corrosion.
    Air Bath Oscillator
    1. Temperature: The temperature is controlled within 5°C to 50°C.
    2. Placement Environment: It should be placed on a flat and stable countertop, avoiding direct sunlight and strong electromagnetic interference.
    3. Ventilation: Excellent ventilation conditions are necessary to ensure the equipment's heat dissipation and the accuracy of temperature control.

    Precautions:
    Water Bath Oscillator
    1. Water Level Inspection: Before usage, it is necessary to inspect whether the water level in the water bath tank is appropriate, ensuring that the water level is higher than the heating tubes to avoid dry burning and damage to the equipment.
    2. Water Quality Maintenance: Regularly replace the water in the water bath tank to prevent the accumulation of scale, which might affect the heating effect and the equipment's service life.
    3. Sample Placement: Samples should be placed on a dedicated sample rack, avoiding direct contact with the wall of the water bath tank to avoid influencing temperature uniformity.
    4. Temperature Control: When setting the temperature, it should be precisely set in accordance with the experimental requirements to avoid temperatures that are too high or too low, which could impact the samples.
    5. Cleaning and Maintenance: Promptly clean up any debris and residues in the water bath tank after usage and regularly clean and disinfect the equipment.
    6. Safety Precautions: Wear protective gloves during operation to avoid scalding from hot water. After usage, disconnect the power supply to ensure safety.

    Air Bath Oscillator
    1. Temperature Calibration: Regularly inspect the accuracy of the temperature sensor to ensure the temperature is controlled within the preset range.
    2. Sample Fixation: Samples should be firmly placed on the sample rack to prevent shaking or dropping during oscillation.
    3. Ventilation Requirements: Ensure there is sufficient space around the equipment to guarantee good ventilation and prevent overheating due to poor heat dissipation.
    4. Cleaning and Maintenance: Regularly clean the dust and debris inside the equipment to maintain its cleanliness and good operational status.
    5. Power Check: Before usage, inspect whether the power cord and socket are normal to avoid equipment damage due to power issues.
    6. Safe Operation: During the equipment's operation, avoid opening the door to prevent influencing temperature uniformity and experimental results. After usage, disconnect the power supply and clean the interior of the equipment.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Graphite Crucible,With Lid

Price:

6

USD

Delivery:

7 Days


Graphite crucibles are a type of high-temperature containers fabricated from graphite.

Speed Control Multi Purpose Oscillator

Price:

226

USD

Delivery:

30 Days


Speed Control Multi Purpose Oscillator is a large-capacity, digitally-displayed, and speed-stabilized manufacturing apparatus specifically developed for modern bioengineering production units.

Graphite Crucible,Without Lid

Price:

4

USD

Delivery:

7 Days


Graphite crucibles are a type of high-temperature containers fabricated from graphite.

Liquid Liquid Extraction Instrument

Price:

3763

USD

Delivery:

30 Days


Liquid Liquid Extraction Instrument employs a novel closed, silent and clean air internal circulation oscillation principle and a bidirectional gas-liquid mixing technique.

Soxhlet Extraction Apparatus

Price:

288

USD

Delivery:

30 Days


The Soxhlet extractor is a frequently employed extraction apparatus in laboratories. It is composed of three components: the extraction flask, the extraction tube, and the condenser.

Online consultation


Name:

Submit