Electrophoresis Power Supply
Electrophoresis Power Supply(Adapted For RUISECI Electrophoresis Tank)
REUN-EP-A

Brand:
RUISCI
-
Choice
- REUN-EP-A-01,10~300V,AdjustableIn1VIncrements
- REUN-EP-B-01,5~600V,1~600mA,5~300W
- REUN-EP-B-02,5~600V,1~1200mA,5~300W
Inventory
567
隐藏域元素占位
Overview
The electrophoresis power supply is essential equipment for laboratory electrophoresis experiments. It furnishes a stable electric field for electrophoresis, which directly affects the accuracy and reproducibility of experimental outcomes.
Features
1. REUN-EP-A-01: Suitable for common electrophoresis experiments such as horizontal and vertical transfer; the shell is made of high-strength flame-retardant material through single-step injection molding; constant voltage and constant current can be switched freely with high stability and quick parameter setup; silicone keys are insulating and resistant to aging; three-digit high-definition digital tubes display various parameters, and automatically detect and report faults; it can drive four identical electrophoresis tanks at a time, with accurate and stable output without fluctuations; when one parameter is set, the other two are automatically generated.
2. REUN-EP-B: Continuously adjustable constant voltage, constant current and constant power, stable and reliable; equipped with a large touch screen for convenient touch operation; a digital keyboard is automatically generated during setting, and timer, temperature, operation status and various prompt operations are displayed; when one of the voltage, current or power is set to be constant, the other two will automatically adjust to the maximum value without manual adjustment.
Technical data
Precautions:
1. Check the equipment: Ensure that the equipment is intact and the power cord is properly connected.
2. Set parameters: According to the experimental requirements, correctly set the voltage, current and time.
3. Connect the electrophoresis tank: Make sure the electrodes of the electrophoresis tank are correctly connected, paying attention to the positive and negative poles.
4. Start electrophoresis: After confirming that the settings are correct, turn on the power to start the electrophoresis.
5. Monitor the process: Closely observe the electrophoresis process to ensure there are no abnormal situations.
6. End electrophoresis: Stop the power when the preset time or effect is reached.
7. Avoid misoperation: Strictly follow the operating procedures to avoid misoperation.
8. Regular maintenance: Regularly calibrate and maintain the equipment to ensure stable performance.
9. Keep clean: After electrophoresis, clean the electrophoresis tank and electrodes in time.
10. Safety measures: Ensure that the equipment is properly grounded to avoid the risk of electric shock.
keyword:
Electrophoresis Apparatus
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Electrophoresis Power Supply
- Subtitle: Electrophoresis Power Supply(Adapted For RUISECI Electrophoresis Tank)
- Model: REUN-EP-A
- 全部型号: Electrophoresis Apparatus(Adapted For RUISECI Electrophoresis Tank),REUN-EP-A-01,REUN-EP-B-01,REUN-EP-B-02
The electrophoresis power supply is essential equipment for laboratory electrophoresis experiments.
The electrophoresis power supply is essential equipment for laboratory electrophoresis experiments. It furnishes a stable electric field for electrophoresis, which directly affects the accuracy and reproducibility of experimental outcomes.
-
1. REUN-EP-A-01: Suitable for common electrophoresis experiments such as horizontal and vertical transfer; the shell is made of high-strength flame-retardant material through single-step injection molding; constant voltage and constant current can be switched freely with high stability and quick parameter setup; silicone keys are insulating and resistant to aging; three-digit high-definition digital tubes display various parameters, and automatically detect and report faults; it can drive four identical electrophoresis tanks at a time, with accurate and stable output without fluctuations; when one parameter is set, the other two are automatically generated.
2. REUN-EP-B: Continuously adjustable constant voltage, constant current and constant power, stable and reliable; equipped with a large touch screen for convenient touch operation; a digital keyboard is automatically generated during setting, and timer, temperature, operation status and various prompt operations are displayed; when one of the voltage, current or power is set to be constant, the other two will automatically adjust to the maximum value without manual adjustment. -
Precautions:
1. Check the equipment: Ensure that the equipment is intact and the power cord is properly connected.
2. Set parameters: According to the experimental requirements, correctly set the voltage, current and time.
3. Connect the electrophoresis tank: Make sure the electrodes of the electrophoresis tank are correctly connected, paying attention to the positive and negative poles.
4. Start electrophoresis: After confirming that the settings are correct, turn on the power to start the electrophoresis.
5. Monitor the process: Closely observe the electrophoresis process to ensure there are no abnormal situations.
6. End electrophoresis: Stop the power when the preset time or effect is reached.
7. Avoid misoperation: Strictly follow the operating procedures to avoid misoperation.
8. Regular maintenance: Regularly calibrate and maintain the equipment to ensure stable performance.
9. Keep clean: After electrophoresis, clean the electrophoresis tank and electrodes in time.
10. Safety measures: Ensure that the equipment is properly grounded to avoid the risk of electric shock.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation