Microplate Reader

RMCR-A,RMCR-MF-A


RUISCI

Brand:

RUISCI


USD

75

Untaxed

EXW factory


  • Choice
    • RMCR-A-96A,7 in.,400 ~ 800 nm
    • RMCR-A-96B,10.4 in.,400 ~ 800 nm
    • RMCR-A-96C,190 ~ 1100 nm, 0.1 nm Steps
    • RMCR-MF-A-01,ELISA Plate
Quantity
-
+

Inventory

788

隐藏域元素占位


Microplate Reader performs multi-mode detection including absorbance, fluorescence, and chemiluminescence measurements, making it ideal for biological and pharmaceutical research applications. Featuring a broad wavelength range, it delivers high sensitivity, exceptional accuracy, and outstanding repeatability. The unit incorporates a high-resolution touchscreen interface for intuitive operation while supporting rapid detection and secure data storage capabilities.


1. Full-screen display of the entire 96-well plate data: Intuitive visual layout interface for plate operation;multiple different tests can be performed on the same plate,allowing for both qualitative and quantitative detection on the same plate.
2. Multiple measurement modes: single-wavelength detection, dual-wavelength detection, two-point method, kinetic measurement, enzyme inhibition rate endpoint method, rate method.
3. Built-in embedded system enables standalone operation - control, data storage, and printing without external computer.
4. Multiple calculation modes available: absorbance measurement, Cut-Off qualitative analysis, single-point calibration, polynomial regression, linear regression, exponential regression, logarithmic regression, double logarithmic regression, log-logit, power regression, four-parameter logistic, and enzyme inhibition rate are available.
5. RMCR-A-96C: Capable of microplate incubation, with the maximum temperature reaching up to 45°C. It features a linear oscillation function for microplates.

Technical data

Precautions:
1. Periodic Calibration: Ensure the accuracy of the instrument by conducting wavelength and absorbance calibrations on a regular basis.
2. Sample Preparation: Maintain sample uniformity to prevent excessively high or low absorbance.
3. Microplate Cleaning: Clean plates thoroughly pre and post-use to avoid cross-contamination.
4. Consistent Optical Path: Ensure consistent sample filling to maintain the same optical path.
5. Appropriate Wavelength: Select the suitable detection wavelength according to the experiment.
6. Photobleaching Prevention: Minimize light exposure for photosensitive samples.
7. Software Operation: Be familiar with the operation process and set the parameters accurately.
8. Safe Usage: Comply with laboratory safety regulations and use protective equipment.
9. Accurate Record Keeping: Record the experimental conditions in detail for facilitating result verification.

keyword:

ELISA Reader

Multimode Microplate Reader

Absorbance Reader

Previous:

Next:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Microplate Reader
    • Subtitle: Microplate Reader
    • Model: RMCR-A,RMCR-MF-A
    • 全部型号: ELISA Reader,Multimode Microplate Reader,Absorbance Reader,RMCR-A-96A,RMCR-A-96B,RMCR-A-96C,RMCR-MF-A-01

    Microplate Reader performs multi-mode detection including absorbance, fluorescence, and chemiluminescence measurements, making it ideal for biological and pharmaceutical research applications.

    Microplate Reader performs multi-mode detection including absorbance, fluorescence, and chemiluminescence measurements, making it ideal for biological and pharmaceutical research applications. Featuring a broad wavelength range, it delivers high sensitivity, exceptional accuracy, and outstanding repeatability. The unit incorporates a high-resolution touchscreen interface for intuitive operation while supporting rapid detection and secure data storage capabilities.

  • 1. Full-screen display of the entire 96-well plate data: Intuitive visual layout interface for plate operation;multiple different tests can be performed on the same plate,allowing for both qualitative and quantitative detection on the same plate.
    2. Multiple measurement modes: single-wavelength detection, dual-wavelength detection, two-point method, kinetic measurement, enzyme inhibition rate endpoint method, rate method.
    3. Built-in embedded system enables standalone operation - control, data storage, and printing without external computer.
    4. Multiple calculation modes available: absorbance measurement, Cut-Off qualitative analysis, single-point calibration, polynomial regression, linear regression, exponential regression, logarithmic regression, double logarithmic regression, log-logit, power regression, four-parameter logistic, and enzyme inhibition rate are available.
    5. RMCR-A-96C: Capable of microplate incubation, with the maximum temperature reaching up to 45°C. It features a linear oscillation function for microplates.

  • Precautions:
    1. Periodic Calibration: Ensure the accuracy of the instrument by conducting wavelength and absorbance calibrations on a regular basis.
    2. Sample Preparation: Maintain sample uniformity to prevent excessively high or low absorbance.
    3. Microplate Cleaning: Clean plates thoroughly pre and post-use to avoid cross-contamination.
    4. Consistent Optical Path: Ensure consistent sample filling to maintain the same optical path.
    5. Appropriate Wavelength: Select the suitable detection wavelength according to the experiment.
    6. Photobleaching Prevention: Minimize light exposure for photosensitive samples.
    7. Software Operation: Be familiar with the operation process and set the parameters accurately.
    8. Safe Usage: Comply with laboratory safety regulations and use protective equipment.
    9. Accurate Record Keeping: Record the experimental conditions in detail for facilitating result verification.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Electrophoresis Power Supply

Price:

970

USD

Delivery:

30 Days


The electrophoresis power supply is essential equipment for laboratory electrophoresis experiments.

Electrophoresis Tank

Price:

395

USD

Delivery:

30 Days


The electrophoresis tank is an important device used for the separation and analysis of biomacromolecules such as proteins, DNA, and RNA.

Activated Carbon Exhaust Treatment Device

Price:

248

USD

Delivery:

30 Days


The activated carbon exhaust treatment device is a device employed for purifying laboratories.

PCR Instrument

Price:

3900

USD

Delivery:

30 Days


The Real Time PCR Instrument is a device employed for real-time monitoring and quantitative analysis of DNA amplification.

Tube Furnace

Price:

481

USD

Delivery:

30 Days


The Tube Furnace is a heating equipment employed in domains like materials science and chemistry, possessing characteristics such as precise temperature control and uniform heating.

Online consultation


Name:

Submit