Overview
The Automated Liquid Handling System is a fully automated pre-analytical sample processing device used in scenarios such as medical diagnostics, disease control screening, food safety testing, and forensic identification. Its primary function is to accurately, efficiently, and safely aliquot liquid samples from collection tubes into standard deep-well plates or PCR plates, facilitating subsequent nucleic acid extraction, detection, or analysis.
Features
Features:
1.Fully automated closed system: The system automatically executes operations including barcode scanning of sample tubes, cap opening, liquid aspiration, sample dispensing, and cap closing, significantly enhancing the throughput of large-scale experimental testing.
2.High-speed and high-precision performance: Utilizing high-speed, high-precision pipetting technology, it processes 96 samples within 20 minutes, covering the entire workflow encompassing information verification, sample cap opening/liquid aspiration, sample transfer, cap closing, and vortex mixing.
3.Integrated automated processing platform: Features an intuitive touchscreen interface for simple operation, delivers high precision with a coefficient of variation (CV) ≤1%, supports scanning of both QR codes and barcodes, incorporates safety safeguards (e.g., UV lamps, HEPA filtration), and enables fully automated operation.
Technical data

Working Environment:
1.Closed sample processing.
2.Temperature: 15~35°C.
3.Humidity: 20%~80% RH (non-condensing).
Precautions:
1.During the aliquoting process, personnel must wear gloves, masks, goggles, and other protective equipment to prevent biological contamination or chemical exposure.
2.Aliquot processing shall be conducted in a clean, sterile environment to avoid external contamination.
3.Each sample must be accurately labeled with patient information, sample type, collection time, and other relevant details to prevent misidentification.
4.After each use, the aliquoting module and tubing must be thoroughly cleaned and disinfected to eliminate residual contamination.
5.Operate the equipment within its specified maximum throughput to avoid mechanical failures caused by overloading.
6.In the event of abnormalities (e.g., blockage, liquid leakage, or barcode recognition failure), immediately shut down the equipment, document the issue, and follow established protocols for resolution.
keyword:
Cup Dispensing Processing System
Cup Aliquot Processing System
Automated Cup Distribution System
Sample Cup Handling and Processing System
Automated Sample Aliquot System
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Automated Liquid Handling System
- Subtitle: Automated Liquid Handling System
- Model: RCD-A
- 全部型号: RCD-A-01,Cup Dispensing Processing System,Cup Aliquot Processing System,Automated Cup Distribution System,Sample Cup Handling and Processing System,Automated Sample Aliquot System
The Automated Liquid Handling System is a fully automated pre-analytical sample processing device used in scenarios such as medical diagnostics, disease control screening, food safety testing, and forensic identification.
The Automated Liquid Handling System is a fully automated pre-analytical sample processing device used in scenarios such as medical diagnostics, disease control screening, food safety testing, and forensic identification. Its primary function is to accurately, efficiently, and safely aliquot liquid samples from collection tubes into standard deep-well plates or PCR plates, facilitating subsequent nucleic acid extraction, detection, or analysis.
-
Features:
1.Fully automated closed system: The system automatically executes operations including barcode scanning of sample tubes, cap opening, liquid aspiration, sample dispensing, and cap closing, significantly enhancing the throughput of large-scale experimental testing.
2.High-speed and high-precision performance: Utilizing high-speed, high-precision pipetting technology, it processes 96 samples within 20 minutes, covering the entire workflow encompassing information verification, sample cap opening/liquid aspiration, sample transfer, cap closing, and vortex mixing.
3.Integrated automated processing platform: Features an intuitive touchscreen interface for simple operation, delivers high precision with a coefficient of variation (CV) ≤1%, supports scanning of both QR codes and barcodes, incorporates safety safeguards (e.g., UV lamps, HEPA filtration), and enables fully automated operation. -

Working Environment:
1.Closed sample processing.
2.Temperature: 15~35°C.
3.Humidity: 20%~80% RH (non-condensing).Precautions:
1.During the aliquoting process, personnel must wear gloves, masks, goggles, and other protective equipment to prevent biological contamination or chemical exposure.
2.Aliquot processing shall be conducted in a clean, sterile environment to avoid external contamination.
3.Each sample must be accurately labeled with patient information, sample type, collection time, and other relevant details to prevent misidentification.
4.After each use, the aliquoting module and tubing must be thoroughly cleaned and disinfected to eliminate residual contamination.
5.Operate the equipment within its specified maximum throughput to avoid mechanical failures caused by overloading.
6.In the event of abnormalities (e.g., blockage, liquid leakage, or barcode recognition failure), immediately shut down the equipment, document the issue, and follow established protocols for resolution.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation