Automatic Polarimeter
Automatic Polarimeter
RAP-A
Brand:
RUISCI
-
Click to select
- RAP-A-01,≤0.01°
- RAP-A-02,≤0.003°,≤0.009°Z(Sugar Degree)
- RAP-A-03,≤0.002°,≤0.006°Z(Sugar Degree)
Inventory
504
隐藏域元素占位
Overview
The Automatic Polarimeter is an instrument used to measure the optical rotation of substances. By determining the optical rotation of samples, it can be used to analyze and determine the concentration, content and purity of substances, etc.
Features
Features:
1. It adopts high-precision photoelectric sensors and optical components, capable of accurately detecting the angle change of polarized light after passing through the sample. The measurement accuracy is usually up to ±0.001°, which can meet the precise detection requirements of trace optically active substances.
2. The instrument adopts a fully automated operation process. Just place the sample in the sample cell and press the start button to complete the measurement. There is no need for complex manual adjustments and data calculations.
3. It has the advantages of high efficiency, stable wavelength, fast response speed, low power consumption, and long service life. It can be used immediately after startup without preheating.
4. It uses photoelectric detection and microcomputer control technology, with a large-screen backlit LCD display for clear and intuitive data presentation.
5. It uses long-life LEDs with a lifespan of over 20,000 hours as the light source, replacing the previous low-life and easily damaged sodium lamps.
Technical data

Precautions:
1. Place the instrument on a stable and level platform, avoiding direct sunlight, vibration, and strong electromagnetic interference. Ensure good air circulation around the instrument and keep it away from corrosive gases and liquids to prevent moisture damage.
2. Check the instrument's appearance for any damage, ensure all components are securely installed, and verify that power cords, data cables, and other connections are normal to ensure the instrument is in good working condition.
3. After measurement, promptly clean the polarimeter tube and sample chamber. Rinse the polarimeter tube with distilled water or an appropriate solvent to remove residual samples, preventing crystallization or deterioration that could affect subsequent measurements. Also, wipe the sample chamber and the instrument's surface to maintain cleanliness and dryness.
4. Turn off the instrument's power, unplug the power cord, and return the instrument to its initial state. Store the polarimeter tube and other accessories properly to avoid damage.
5. Regularly calibrate the instrument to ensure measurement accuracy and stability. Clean the interior and exterior of the instrument regularly to maintain its good condition.
6. During operation, avoid direct observation of the instrument's light source to prevent eye damage.
keyword:
Automatic Polarimeter
Digital Saccharimeter Polarimeter
Brix And Optical Rotation Analyzer
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Automatic Polarimeter
- Subtitle: Automatic Polarimeter
- Model: RAP-A
- 全部型号: RAP-A-01,RAP-A-02,RAP-A-03,Automatic Polarimeter,Digital Saccharimeter Polarimeter,Brix And Optical Rotation Analyzer
The Automatic Polarimeter is an instrument used to measure the optical rotation of substances.
The Automatic Polarimeter is an instrument used to measure the optical rotation of substances. By determining the optical rotation of samples, it can be used to analyze and determine the concentration, content and purity of substances, etc.
-
Features:
1. It adopts high-precision photoelectric sensors and optical components, capable of accurately detecting the angle change of polarized light after passing through the sample. The measurement accuracy is usually up to ±0.001°, which can meet the precise detection requirements of trace optically active substances.
2. The instrument adopts a fully automated operation process. Just place the sample in the sample cell and press the start button to complete the measurement. There is no need for complex manual adjustments and data calculations.
3. It has the advantages of high efficiency, stable wavelength, fast response speed, low power consumption, and long service life. It can be used immediately after startup without preheating.
4. It uses photoelectric detection and microcomputer control technology, with a large-screen backlit LCD display for clear and intuitive data presentation.
5. It uses long-life LEDs with a lifespan of over 20,000 hours as the light source, replacing the previous low-life and easily damaged sodium lamps. -

Precautions:
1. Place the instrument on a stable and level platform, avoiding direct sunlight, vibration, and strong electromagnetic interference. Ensure good air circulation around the instrument and keep it away from corrosive gases and liquids to prevent moisture damage.
2. Check the instrument's appearance for any damage, ensure all components are securely installed, and verify that power cords, data cables, and other connections are normal to ensure the instrument is in good working condition.
3. After measurement, promptly clean the polarimeter tube and sample chamber. Rinse the polarimeter tube with distilled water or an appropriate solvent to remove residual samples, preventing crystallization or deterioration that could affect subsequent measurements. Also, wipe the sample chamber and the instrument's surface to maintain cleanliness and dryness.
4. Turn off the instrument's power, unplug the power cord, and return the instrument to its initial state. Store the polarimeter tube and other accessories properly to avoid damage.
5. Regularly calibrate the instrument to ensure measurement accuracy and stability. Clean the interior and exterior of the instrument regularly to maintain its good condition.
6. During operation, avoid direct observation of the instrument's light source to prevent eye damage.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation