Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Stationary Gas Alarm Controller

Stationary Gas Alarm Controller

RSGA-A


RUISCI

Brand:

RUISCI


USD

750

Untaxed

EXW factory


  • Click to select
    • RSGA-A-01
Quantity
-
+

Inventory

168

隐藏域元素占位


The Stationary Gas Alarm Controller is a safety instrument employed in industrial settings. It collaborates with gas detectors to conduct real - time monitoring of the concentration of specific gases in the environment.


Features:
1. Supports 4-20mA signals, capable of connecting to various detectors and transmitters.
2. Three modes available (6-channel simultaneous display, single-channel cycling, real-time curve), capable of showing maximum/minimum values, gas names, and supporting historical curve viewing.
3. Simultaneous display of six channels or large-font cycling display; Auto/manual screen toggle when exceeding 6 channels.
4. Sound and light alarm, two-level alarm, with high and low limit alarm values settable for each channel.
5. Line disconnection and short circuit detection, detector status detection.
6. Supports data logging, with configurable storage intervals, recording real-time concentrations or alarm information, supporting SD card/USB flash drive storage, and allowing viewing and deletion of records.

Technical data

Precautions:
1. Ensure that the installation environment's temperature and humidity meet the equipment requirements, and avoid adverse conditions such as high temperature, high humidity, and strong electromagnetic interference.
2. The controller should be installed in a position that is convenient for observation and operation, and the display screen should be easily viewable.
3. Avoid installing in areas with poor ventilation or prone to water accumulation.
4. Ensure that the controller's casing is properly grounded to prevent electromagnetic interference and static electricity accumulation.
5. Use power supplies that meet the equipment requirements to avoid voltage fluctuations that may damage the equipment.
6. After installation, calibrate the detector with standard gas to ensure the accuracy of measurement results.
7. Regularly calibrate the detector, especially after changes in environmental conditions or long-term operation of the equipment.
8. Regularly clean the controller's casing and display screen to prevent dust and dirt accumulation. Use a soft cloth or cotton yarn for cleaning and avoid using corrosive cleaning agents.
9. Regularly check and back up data records, including alarm events and historical data. Clear the storage device as needed to ensure sufficient storage space.
10. If the equipment malfunctions or shows abnormal behavior, contact professional technicians for repair in a timely manner. Do not attempt to disassemble or repair it yourself to avoid equipment damage or safety hazards.

keyword:

Stationary Gas Alarm Controller

Fixed Gas Alarm Controller

Fixed Gas Monitor Controller

Industrial Fixed Gas Detector Controller

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Stationary Gas Alarm Controller
    • Subtitle: Stationary Gas Alarm Controller
    • Model: RSGA-A
    • 全部型号: RSGA-A-01,Stationary Gas Alarm Controller,Fixed Gas Alarm Controller,Fixed Gas Monitor Controller,Industrial Fixed Gas Detector Controller

    The Stationary Gas Alarm Controller is a safety instrument employed in industrial settings. It collaborates with gas detectors to conduct real - time monitoring of the concentration of specific gases in the environment.

    The Stationary Gas Alarm Controller is a safety instrument employed in industrial settings. It collaborates with gas detectors to conduct real - time monitoring of the concentration of specific gases in the environment.

  • Features:
    1. Supports 4-20mA signals, capable of connecting to various detectors and transmitters.
    2. Three modes available (6-channel simultaneous display, single-channel cycling, real-time curve), capable of showing maximum/minimum values, gas names, and supporting historical curve viewing.
    3. Simultaneous display of six channels or large-font cycling display; Auto/manual screen toggle when exceeding 6 channels.
    4. Sound and light alarm, two-level alarm, with high and low limit alarm values settable for each channel.
    5. Line disconnection and short circuit detection, detector status detection.
    6. Supports data logging, with configurable storage intervals, recording real-time concentrations or alarm information, supporting SD card/USB flash drive storage, and allowing viewing and deletion of records.

  • Precautions:
    1. Ensure that the installation environment's temperature and humidity meet the equipment requirements, and avoid adverse conditions such as high temperature, high humidity, and strong electromagnetic interference.
    2. The controller should be installed in a position that is convenient for observation and operation, and the display screen should be easily viewable.
    3. Avoid installing in areas with poor ventilation or prone to water accumulation.
    4. Ensure that the controller's casing is properly grounded to prevent electromagnetic interference and static electricity accumulation.
    5. Use power supplies that meet the equipment requirements to avoid voltage fluctuations that may damage the equipment.
    6. After installation, calibrate the detector with standard gas to ensure the accuracy of measurement results.
    7. Regularly calibrate the detector, especially after changes in environmental conditions or long-term operation of the equipment.
    8. Regularly clean the controller's casing and display screen to prevent dust and dirt accumulation. Use a soft cloth or cotton yarn for cleaning and avoid using corrosive cleaning agents.
    9. Regularly check and back up data records, including alarm events and historical data. Clear the storage device as needed to ensure sufficient storage space.
    10. If the equipment malfunctions or shows abnormal behavior, contact professional technicians for repair in a timely manner. Do not attempt to disassemble or repair it yourself to avoid equipment damage or safety hazards.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Static Grounding Alarm

Price:

52

USD

Delivery:

7 Days


The Static Grounding Alarm is a device used to ensure electrostatic safety and is widely applied in flammable and explosive sites such as petrochemical plants, oil depots, and gas stations.

Spray Dryer

Price:

4745

USD

Delivery:

30 Days


Spray dryer is a highly efficient drying device.

Forced Air Convection Drying Oven

Price:

97

USD

Delivery:

30 Days


Electric Heated Constant Temperature Drying Oven - Forced Air Convection Drying Oven achieves rapid and uniform heating by forcibly circulating hot air inside the chamber with a fan.

K/J Thermometers

Price:

23

USD

Delivery:

30 Days


K/J Thermometers refer to temperature measurement devices based on K-type and J-type thermocouples.

Flame Photometer

Price:

1150

USD

Delivery:

30 Days


Flame PhotometerFlame Photometer is an instrument used for analyzing chemical components, mainly for determining the content of certain metal elements in samples.

Online consultation


Name: