Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Pressure Calibrator

Pressure Calibrator

RPMC-A,RPMC-B,RPMC-PA-A


RUISCI

Brand:

RUISCI


USD

120

Untaxed

EXW factory


  • Click to select
    • RPMC-A-01,Hydraulic Calibration Bench,-0.05~60MPa
    • RPMC-A-02,Hydraulic Calibration Bench,0~60MPa,330*410*170mm
    • RPMC-A-03,Hydraulic Calibration Bench,0~60MPa,350*380*170mm
    • RPMC-A-04,Portable Hydraulic Pump,0~60MPa
    • RPMC-B-01,Pneumatic Calibration Bench,0~10MPa
    • RPMC-B-02,Portable Pneumatic Pump,-0.095~6MPa
    • RPMC-PA-A-01,Precision Pressure Gauge,0.4%FS
    • RPMC-PA-A-02,Precision Pressure Gauge,0.25%FS
    • RPMC-PA-A-03,Precision Digital Pressure Gauge,0.1%FS
    • RPMC-PA-A-04,Precision Digital Pressure Gauge,0.05%FS
    • RPMC-PA-A-05,Oil-Water Isolator
Quantity
-
+

Inventory

2827

隐藏域元素占位


Pressure Calibrator is a high-precision pressure measurement instrument,specifically designed for calibrating pressure gauges,pressure sensors,pressure transmitters,and other pressure measurement devices to ensure the accuracy and reliability of their measurement results.


1.Manual Operation:Pressure can be increased or decreased manually,making it suitable for both field and laboratory use.
2.Portable and Flexible:Compact in size and lightweight,it is easy to carry to different locations.
3.High Precision and Reliability:Provides highly accurate measurements,suitable for calibrating pressure gauges,sensors,and other devices.
4.User-Friendly:Intuitive operation with no complicated settings required,suitable for a wide range of pressure measurements.

Technical data

1.Equipment inspection: Before use, check the appearance of the equipment to ensure it is intact, without damage or leakage. Confirm that the equipment is within the calibration validity period and its accuracy meets the requirements.
2.Operating environment: Ensure that the temperature and humidity of the operating environment meet the equipment requirements and avoid using it in extreme conditions. Keep the operating environment clean to prevent dust, oil stains and other impurities from affecting the calibration accuracy.
3.Operating procedures: When manually pressurizing, do it slowly and evenly to avoid pressure shock that may damage the calibrated equipment. Do not exceed the range of the calibrator and the calibrated equipment to prevent damage to the equipment.
4.Cleaning and maintenance: Clean the equipment promptly after use, especially the pressure interface and pump parts. Store it in a dry and clean environment to prevent moisture and dust accumulation.
5.Safe operation: Wear necessary protective equipment such as gloves during operation. Ensure that connections are secure to prevent dangerous leakage of high-pressure gas.

keyword:

Pressure Calibrator

Pressure Calibration Device

Portable Pressure Calibrator

Hydraulic/Pneumatic Pressure Calibrator

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Pressure Calibrator
    • Subtitle: Pressure Calibrator
    • Model: RPMC-A,RPMC-B,RPMC-PA-A
    • 全部型号: RPMC-A-01,RPMC-A-02,RPMC-A-03,RPMC-A-04,RPMC-B-01,RPMC-B-02,RPMC-PA-A-01,RPMC-PA-A-02,RPMC-PA-A-03,RPMC-PA-A-04,RPMC-PA-A-05,Pressure Calibrator,Pressure Calibration Device,Portable Pressure Calibrator,Hydraulic/Pneumatic Pressure Calibrator

    Pressure Calibrator is a high-precision pressure measurement instrument,specifically designed for calibrating pressure gauges,pressure sensors,pressure transmitters,and other pressure measurement devices to ensure the accuracy and reliability of their measurement results.

    Pressure Calibrator is a high-precision pressure measurement instrument,specifically designed for calibrating pressure gauges,pressure sensors,pressure transmitters,and other pressure measurement devices to ensure the accuracy and reliability of their measurement results.

  • 1.Manual Operation:Pressure can be increased or decreased manually,making it suitable for both field and laboratory use.
    2.Portable and Flexible:Compact in size and lightweight,it is easy to carry to different locations.
    3.High Precision and Reliability:Provides highly accurate measurements,suitable for calibrating pressure gauges,sensors,and other devices.
    4.User-Friendly:Intuitive operation with no complicated settings required,suitable for a wide range of pressure measurements.

  • 1.Equipment inspection: Before use, check the appearance of the equipment to ensure it is intact, without damage or leakage. Confirm that the equipment is within the calibration validity period and its accuracy meets the requirements.
    2.Operating environment: Ensure that the temperature and humidity of the operating environment meet the equipment requirements and avoid using it in extreme conditions. Keep the operating environment clean to prevent dust, oil stains and other impurities from affecting the calibration accuracy.
    3.Operating procedures: When manually pressurizing, do it slowly and evenly to avoid pressure shock that may damage the calibrated equipment. Do not exceed the range of the calibrator and the calibrated equipment to prevent damage to the equipment.
    4.Cleaning and maintenance: Clean the equipment promptly after use, especially the pressure interface and pump parts. Store it in a dry and clean environment to prevent moisture and dust accumulation.
    5.Safe operation: Wear necessary protective equipment such as gloves during operation. Ensure that connections are secure to prevent dangerous leakage of high-pressure gas.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Electrical Metrology Calibration

Price:

5700

USD

Delivery:

30 Days


Electrical Metrology Calibration is a process that verifies and adjusts the accuracy,stability,and consistency of electrical measurement instruments through a series of standard devices and technical means to ensure the accuracy and reliability of their measurement results.

Digital Anemometer

Price:

13

USD

Delivery:

30 Days


Digital Anemometer is a precise instrument used to measure the speed of air flow.

Vane Probe

Price:

19

USD

Delivery:

30 Days


The Vane Probe is a key component of an anemometer, consisting of a set of vanes.

Temperature Calibrator

Price:

1700

USD

Delivery:

30 Days


The Temperature Calibrator is portable, easy to use, and enables quick and reliable temperature calibration.

Borescope

Price:

122

USD

Delivery:

30 Days


An Borescope is a device employed for the non-destructive inspection of the internal structure and components of equipment.

Online consultation


Name:

Submit