Acid Alkaline Concentration Meter

Acid Alkaline Concentration Meter

RABC-A,RABC-PH-A


RUISCI

Brand:

RUISCI


USD

650

Untaxed

EXW factory


  • Click to select
    • RABC-A-01,ABS Plastic
    • RABC-PH-A-01,Standard Temperature
    • RABC-PH-A-02,High Temperature
Quantity
-
+

Inventory

594

隐藏域元素占位


Acid-Base Concentration Meter calculates concentration by detecting the linear relationship between the solution's conductivity and concentration. Temperature changes can cause fluctuations in conductivity. Therefore, when paired with a Digital PH Electrode, it can automatically compensate for the influence of environmental temperature, ensuring data accuracy.


1. It can be paired with acid-base concentration sensors for rapid response and precise measurement.
2. Provides dual 4-20mA outputs and RS485 digital communication interface.
3. It has a data logging function, allowing users to easily view historical data and historical curves.
4. Data visualization is equipped with a liquid crystal display, providing intuitive and clear measurement results.

Technical data

Precautions:
1. Storage temperature and humidity: Temperature -40 to 70℃. Relative humidity ≤ 95% RH (no condensation).
2. Working environment: Temperature -20 to 50℃; Humidity ≤ 95% RH (no condensation); Altitude ≤ 2000m; Overvoltage category II.
3. Wiring errors, especially incorrect power connection, can cause complete damage to the sensor!
4. The threaded part and above (including the cable) must be completely isolated from the measured solution (even with glue!). Long-term immersion (dripping) of liquid will damage the sensor!
5. There is a filter capacitor inside the heat shrink tube at the end of the cable (to prevent power fluctuations and interference). Do not cut it off!
6. To ensure accurate measurement by the sensor, it is recommended to keep a 40mm space around the sensor to avoid other substances approaching the sensing area. Different space distances will change the proportionality coefficient, and parameter balancing and compensation should be carried out.
7. When installing, the circular hole of the sensing area should face upwards or be tilted upwards to avoid occasional air bubbles (or use software filtering methods to remove them); suspend the sensor in the solution to prevent contact with the container (simply placing it in the container randomly will cause measurement errors), and keep the probe stationary during the measurement process.
8. If the power is off for a long time and then turned on, the conductance value may drift slightly within 5 to 15 minutes.
9. When installing, do not try to tighten the connection by rotating or twisting the "ring-shaped" end of the sensor, as this may cause the sensor housing to break.
10. When wiring, do not pass the cable of the probe through any pipes with AC or DC current. Electrical signals may interfere with the sensor signal.
11. Due to the significant temperature difference that may exist between the inside of the probe and the detected liquid, it is clearly recommended: in cases requiring precise measurement or rapid response, do not use the built-in temperature sensor of the probe as the temperature sensing element of the detected liquid.

keyword:

Acid-Base Concentration Meter

Online Acid Alkali Concentration Meter

Chemical Concentration Meter

igital PH Electrode

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Acid Alkaline Concentration Meter
    • Subtitle: Acid Alkaline Concentration Meter
    • Model: RABC-A,RABC-PH-A
    • 全部型号: RABC-A-01,RABC-PH-A-01,RABC-PH-A-02,Acid-Base Concentration Meter,Online Acid Alkali Concentration Meter,Chemical Concentration Meter,igital PH Electrode

    Acid-Base Concentration Meter calculates concentration by detecting the linear relationship between the solution's conductivity and concentration.

    Acid-Base Concentration Meter calculates concentration by detecting the linear relationship between the solution's conductivity and concentration. Temperature changes can cause fluctuations in conductivity. Therefore, when paired with a Digital PH Electrode, it can automatically compensate for the influence of environmental temperature, ensuring data accuracy.

  • 1. It can be paired with acid-base concentration sensors for rapid response and precise measurement.
    2. Provides dual 4-20mA outputs and RS485 digital communication interface.
    3. It has a data logging function, allowing users to easily view historical data and historical curves.
    4. Data visualization is equipped with a liquid crystal display, providing intuitive and clear measurement results.

  • Precautions:
    1. Storage temperature and humidity: Temperature -40 to 70℃. Relative humidity ≤ 95% RH (no condensation).
    2. Working environment: Temperature -20 to 50℃; Humidity ≤ 95% RH (no condensation); Altitude ≤ 2000m; Overvoltage category II.
    3. Wiring errors, especially incorrect power connection, can cause complete damage to the sensor!
    4. The threaded part and above (including the cable) must be completely isolated from the measured solution (even with glue!). Long-term immersion (dripping) of liquid will damage the sensor!
    5. There is a filter capacitor inside the heat shrink tube at the end of the cable (to prevent power fluctuations and interference). Do not cut it off!
    6. To ensure accurate measurement by the sensor, it is recommended to keep a 40mm space around the sensor to avoid other substances approaching the sensing area. Different space distances will change the proportionality coefficient, and parameter balancing and compensation should be carried out.
    7. When installing, the circular hole of the sensing area should face upwards or be tilted upwards to avoid occasional air bubbles (or use software filtering methods to remove them); suspend the sensor in the solution to prevent contact with the container (simply placing it in the container randomly will cause measurement errors), and keep the probe stationary during the measurement process.
    8. If the power is off for a long time and then turned on, the conductance value may drift slightly within 5 to 15 minutes.
    9. When installing, do not try to tighten the connection by rotating or twisting the "ring-shaped" end of the sensor, as this may cause the sensor housing to break.
    10. When wiring, do not pass the cable of the probe through any pipes with AC or DC current. Electrical signals may interfere with the sensor signal.
    11. Due to the significant temperature difference that may exist between the inside of the probe and the detected liquid, it is clearly recommended: in cases requiring precise measurement or rapid response, do not use the built-in temperature sensor of the probe as the temperature sensing element of the detected liquid.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Soybean Milk Concentration Meter

Price:

215

USD

Delivery:

30 Days


The Soybean Milk Concentration Meter is a specialized instrument employed for measuring the concentration of soy milk or soy juice.

Ethylene Glycol Concentration Meter

Price:

17

USD

Delivery:

30 Days


The Ethylene Glycol Concentration Meter is an instrument specifically designed to measure the concentration of ethylene glycol solutions.

Hydrogen Peroxide Concentration Meter

Price:

414

USD

Delivery:

30 Days


The Hydrogen Peroxide Concentration Meter is a specialized instrument for measuring the concentration of hydrogen peroxide solutions, widely used in the chemical and medical fields.

Potassium Hydroxide Concentration Meter

Price:

143

USD

Delivery:

30 Days


The potassium hydroxide concentration meter is a specialized analytical instrument designed for measuring the concentration of potassium hydroxide (KOH) solutions.

Oil Absorbent Mat

Price:

31

USD

Delivery:

7 Days


Oil Absorbent Mat is a fiber mat made of 100% polypropylene, which is hydrophobic and oleophilic.