Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Clear Glass Buchner Funnel
Clear Glass Buchner Funnel
GF-G
Brand:
RUISCI
-
Click to select
- GF-G-01,30ml,19/26mm
- GF-G-02,30ml,24/29mm
- GF-G-03,60ml,19/26mm
- GF-G-04,60ml,24/29mm
- GF-G-05,100ml,19/26mm
- GF-G-06,100ml,24/29mm
- GF-G-07,150ml,19/26mm
- GF-G-08,150ml,24/29mm
- GF-G-09,200ml,19/26mm
- GF-G-10,200ml,24/29mm
- GF-G-11,250ml,19/26mm
- GF-G-12,250ml,24/29mm
- GF-G-13,350ml,19/26mm
- GF-G-14,350ml,24/29mm
- GF-G-15,500ml,19/26mm
- GF-G-16,500ml,24/29mm
- GF-G-17,1L,19/26mm
- GF-G-18,1L,24/29mm
- GF-G-19,2L,24/40mm
Inventory
5092
隐藏域元素占位
Overview
The Clear Glass Buchner Funnel is a type of glass filtration apparatus employed for solid-liquid separation and gas purification. It is fabricated from high borosilicate glass. The core component is a porous glass plate, which possesses high-temperature resistance, acid and alkali resistance, and chemical stability. Through the effect of negative pressure, liquids or gases achieve separation via the micro-pores of the glass plate. It is applicable to scenarios such as chemical analysis, microbiological detection, and the pharmaceutical industry.
Features
1. Standard Joint: Conforms to standards and has excellent sealing property.
2. High Borosilicate Glass: Withstands high temperatures, has high transparency, and is robust and durable.
3. Pagoda Head: Featuring multiple hoops, distinct edges and corners, and firm connection that is not prone to detachment.
4. Lathe-assisted, Firmly Welded: Welded at 1100°C, subjected to stress relief at 600°C, and naturally cooled with heat preservation in the furnace.
5. The apertures are uniform, the welding is firm, and the glass plate is perforated by laser.
Technical data

Working Environment Conditions:
1. Temperature range: From normal temperature to 180°C. Abrupt temperature variations should be avoided to prevent cracking.
2. Pressure requirements: The positive and negative pressure differential should not exceed 9.8×10⁴ Pa (approximately 1 kg/cm²) to avoid damage to the filter plate caused by excessive pressure.
3. Chemical environment: The high borosilicate glass material is resistant to acids and alkalis; however, it is not applicable for hydrofluoric acid, hot concentrated phosphoric acid, and concentrated alkaline solutions.
4. Usage environment: It needs to be utilized in a dry and clean setting to evade dust contamination and dampness.
Precautions:
1. Select the Appropriate Filter Plate Aperture: Select filter plates with different pore sizes of G0 to G6 based on the experimental requirements to ensure the filtering effect.
2. Timely Cleaning: Immediately soak in dilute acid or detergent solution after use, and then rinse with distilled water to prevent clogging.
3. Handle with Care: Avoid collisions or drops to prevent damage to the funnel.
4. Regular Inspection: Inspect whether the filter plate is clogged or damaged before use to ensure the normal operation of the funnel.
5. Disinfection and Storage: G5 and G6 filter plates can be used for bacterial filtration. After use, they need to be filtered with an acidic solution and dried for storage.
keyword:
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Clear Glass Buchner Funnel
- Subtitle: Clear Glass Buchner Funnel
- Model: GF-G
- 全部型号: GF-G-01,GF-G-02,GF-G-03,GF-G-04,GF-G-05,GF-G-06,GF-G-07,GF-G-08,GF-G-09,GF-G-10,GF-G-11,GF-G-12,GF-G-13,GF-G-14,GF-G-15,GF-G-16,GF-G-17,GF-G-18,GF-G-19,Glass Filtration Buchner,Buchner,Glass Buchner Filtering,Glass Funnel,Separatory Funnel
The Clear Glass Buchner Funnel is a type of glass filtration apparatus employed for solid-liquid separation and gas purification.
The Clear Glass Buchner Funnel is a type of glass filtration apparatus employed for solid-liquid separation and gas purification. It is fabricated from high borosilicate glass. The core component is a porous glass plate, which possesses high-temperature resistance, acid and alkali resistance, and chemical stability. Through the effect of negative pressure, liquids or gases achieve separation via the micro-pores of the glass plate. It is applicable to scenarios such as chemical analysis, microbiological detection, and the pharmaceutical industry.
-
1. Standard Joint: Conforms to standards and has excellent sealing property.
2. High Borosilicate Glass: Withstands high temperatures, has high transparency, and is robust and durable.
3. Pagoda Head: Featuring multiple hoops, distinct edges and corners, and firm connection that is not prone to detachment.
4. Lathe-assisted, Firmly Welded: Welded at 1100°C, subjected to stress relief at 600°C, and naturally cooled with heat preservation in the furnace.
5. The apertures are uniform, the welding is firm, and the glass plate is perforated by laser. -

Working Environment Conditions:
1. Temperature range: From normal temperature to 180°C. Abrupt temperature variations should be avoided to prevent cracking.
2. Pressure requirements: The positive and negative pressure differential should not exceed 9.8×10⁴ Pa (approximately 1 kg/cm²) to avoid damage to the filter plate caused by excessive pressure.
3. Chemical environment: The high borosilicate glass material is resistant to acids and alkalis; however, it is not applicable for hydrofluoric acid, hot concentrated phosphoric acid, and concentrated alkaline solutions.
4. Usage environment: It needs to be utilized in a dry and clean setting to evade dust contamination and dampness.Precautions:
1. Select the Appropriate Filter Plate Aperture: Select filter plates with different pore sizes of G0 to G6 based on the experimental requirements to ensure the filtering effect.
2. Timely Cleaning: Immediately soak in dilute acid or detergent solution after use, and then rinse with distilled water to prevent clogging.
3. Handle with Care: Avoid collisions or drops to prevent damage to the funnel.
4. Regular Inspection: Inspect whether the filter plate is clogged or damaged before use to ensure the normal operation of the funnel.
5. Disinfection and Storage: G5 and G6 filter plates can be used for bacterial filtration. After use, they need to be filtered with an acidic solution and dried for storage.
Q and A
There is currently no content to display
Download
There is currently no content to display
Related products