Low Temperature Magnetic Agitator
Low Temperature Magnetic Agitator
RLM-A
Brand:
RUISCI
-
Click to select
- RLM-A-01
Inventory
66
隐藏域元素占位
Overview
Low Temperature Magnetic Agitator is a frequently utilized apparatus in laboratories, mainly employed for liquid blending and agitation under low-temperature circumstances. It actuates the rotation of the stirrer bar via an inbuilt magnetic drive mechanism to realize homogeneous stirring. The device is furnished with a refrigeration system that can sustain a low-temperature environment and is appropriate for low-temperature reactions. The operation is straightforward, with precise temperature control, and is applicable to experimental operations in domains such as chemistry and biology, guaranteeing a stable and reliable experimental procedure.
Features
1. Offer a low-temperature environment as low as -20 degrees Celsius.
2. Up to 84 evenly distributed stirring points, significantly enhancing experimental efficiency.
3. The patented low-temperature plate design and highly precise temperature control enable the temperature control accuracy of the solution or the plate surface to reach ±0.1°C.
4. Feature manual or automatic liquid reflux functionality.
5. Ten program segments for control, with each segment allowing for the setting of different temperatures and rotational speeds.
6. Incorporate an automatic liquid spill protection function to safely conduct overnight reactions.
7. Provide special customization for any desired stirring points.
Technical data

Before Use
1. Inspect the equipment: Ensure that the power cord, the stirrer, the container, and other accessories are intact and undamaged, and that the stirrer can rotate freely.
2. Choose the appropriate container: The container should be well-sealed and made of a material that is resistant to low temperatures. Avoid using glass containers as they may crack due to excessive temperature differences.
3. Position the stirrer: Place the stirrer at the bottom of the container, ensuring it can make full contact with the solution and does not collide with the container walls.
During Operation
4. Gradually adjust the speed: After activating the equipment, start at a low speed and gradually increase to the required speed to prevent the stirrer from jumping.
5. Control the temperature: Set the appropriate low temperature based on the experimental requirements. Pay attention to the response time of the refrigeration system to avoid excessive temperature fluctuations.
6. Avoid frequent operations: Do not frequently open the equipment or touch the container during the stirring process to avoid affecting the temperature stability and sealing performance.
7. Be safety-conscious: Avoid touching the stirrer or the container while the equipment is in operation to prevent accidents.
After Use
8. Shut down the equipment: After the experiment is completed, turn off the stirrer first, then the refrigeration system, and finally disconnect the power supply.
9. Clean the equipment: Clean the stirrer and the container promptly. Keep the surface of the equipment clean to prevent residues from affecting the next use.
10. Perform regular maintenance: Check the wear of the refrigeration system and the stirring components. Replace the refrigerant or lubricating oil regularly to ensure the normal operation of the equipment.
keyword:
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Low Temperature Magnetic Agitator
- Subtitle: Low Temperature Magnetic Agitator
- Model: RLM-A
- 全部型号: RLM-A-01
Low Temperature Magnetic Agitator is a frequently utilized apparatus in laboratories, mainly employed for liquid blending and agitation under low-temperature circumstances.
Low Temperature Magnetic Agitator is a frequently utilized apparatus in laboratories, mainly employed for liquid blending and agitation under low-temperature circumstances. It actuates the rotation of the stirrer bar via an inbuilt magnetic drive mechanism to realize homogeneous stirring. The device is furnished with a refrigeration system that can sustain a low-temperature environment and is appropriate for low-temperature reactions. The operation is straightforward, with precise temperature control, and is applicable to experimental operations in domains such as chemistry and biology, guaranteeing a stable and reliable experimental procedure.
-
1. Offer a low-temperature environment as low as -20 degrees Celsius.
2. Up to 84 evenly distributed stirring points, significantly enhancing experimental efficiency.
3. The patented low-temperature plate design and highly precise temperature control enable the temperature control accuracy of the solution or the plate surface to reach ±0.1°C.
4. Feature manual or automatic liquid reflux functionality.
5. Ten program segments for control, with each segment allowing for the setting of different temperatures and rotational speeds.
6. Incorporate an automatic liquid spill protection function to safely conduct overnight reactions.
7. Provide special customization for any desired stirring points. -

Before Use
1. Inspect the equipment: Ensure that the power cord, the stirrer, the container, and other accessories are intact and undamaged, and that the stirrer can rotate freely.
2. Choose the appropriate container: The container should be well-sealed and made of a material that is resistant to low temperatures. Avoid using glass containers as they may crack due to excessive temperature differences.
3. Position the stirrer: Place the stirrer at the bottom of the container, ensuring it can make full contact with the solution and does not collide with the container walls.During Operation
4. Gradually adjust the speed: After activating the equipment, start at a low speed and gradually increase to the required speed to prevent the stirrer from jumping.
5. Control the temperature: Set the appropriate low temperature based on the experimental requirements. Pay attention to the response time of the refrigeration system to avoid excessive temperature fluctuations.
6. Avoid frequent operations: Do not frequently open the equipment or touch the container during the stirring process to avoid affecting the temperature stability and sealing performance.
7. Be safety-conscious: Avoid touching the stirrer or the container while the equipment is in operation to prevent accidents.After Use
8. Shut down the equipment: After the experiment is completed, turn off the stirrer first, then the refrigeration system, and finally disconnect the power supply.
9. Clean the equipment: Clean the stirrer and the container promptly. Keep the surface of the equipment clean to prevent residues from affecting the next use.
10. Perform regular maintenance: Check the wear of the refrigeration system and the stirring components. Replace the refrigerant or lubricating oil regularly to ensure the normal operation of the equipment.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.