Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Rotary Evaporator
Rotary Evaporator
RRE-A,RRE-B,RRE-AC-A
Brand:
RUISCI
-
Click to select
- RRE-A-01,1,2L,Manual
- RRE-A-03,3L,Manual
- RRE-A-05,5L,Manual
- RRE-A-10,10L,Manual
- RRE-A-20,20L,Manual
- RRE-A-30,30L,Manual
- RRE-A-50,50L,Manual
- RRE-B-01A,1,2L,Automatic
- RRE-B-01B,1,2L,Digital,Automatic
- RRE-B-01C,1,2L,LCD,Automatic
- RRE-B-05,5L,Automatic
- RRE-B-10,10L,Automatic
- RRE-B-20,20L,Automatic
- RRE-B-50,50L,Automatic
- RRE-AC-A-01,Pump
Inventory
2520
隐藏域元素占位
Overview
Rotary evaporator is a kind of laboratory equipment, which is employed for the continuous distillation of a large amount of volatile solvents under reduced pressure conditions. By rotating the evaporation flask, it increases the surface area of the liquid and accelerates the evaporation rate. The device is usually furnished with a heating bath, vacuum pump and condenser, capable of efficiently recovering the solvents. With simple operation, it is extensively applied in domains such as chemistry and food science for operations like sample concentration and solvent removal, and is an indispensable tool in both scientific research and industrial production.
Features
1. The water tank is fabricated from cylindrical stainless steel: The water tank is constructed with cylindrical stainless steel, featuring strong anti-corrosion capability and a long service life. The heating tank is capable of vertical movement, and the bath pot is intelligently temperature-controlled with digital display.
2. Digital constant temperature control of the water bath pot: The temperature of the instrument is digitally indicated, with intelligent constant temperature control, and the rotational speed is stable, precise and reliable.
3. The instrument is composed of stainless steel and aluminum alloy components: A significant portion of the mechanical structure utilizes stainless steel and aluminum alloy components, and all the glass components are made of high-temperature-resistant high borosilicate glass.
4. Valve-type feeding tube: It enables continuous feeding for the convenience of customers, and the valve-type feeding tube is sheathed with polytetrafluoroethylene (PTFE) tubing.
Technical data



1. Inspect the equipment: Prior to utilization, examine the integrity of the equipment, encompassing sealing rings, glass components, and the vacuum pump, among others.
2. Prepare the sample: Guarantee that the sample quantity is appropriate, not exceeding half of the capacity of the evaporation flask to avert overflow.
3. Install accurately: Install the evaporation flask, condenser tube, and receiving flask correctly, ensuring tight sealing at the connection points.
4. Set the temperature: Establish an appropriate heating temperature based on the boiling point of the solvent to evade overheating.
5. Conduct vacuum operation: Initiate the vacuum pump and gradually decrease the system pressure to prevent sample splashing due to sudden pressure drops.
6. Monitor the process: Closely supervise the temperature, pressure, and solvent evaporation during the distillation process.
7. Avoid dry burning: Ensure that there is always solvent in the evaporation flask to prevent damage to the equipment caused by dry burning.
8. Safety protection: Adorn appropriate personal protective equipment when operating, such as laboratory safety glasses and gloves.
9. Shut down the equipment: Upon the conclusion of the experiment, turn off the heating first, then cease the operation of the vacuum pump, and ultimately switch off the power supply.
10. Clean and maintain: Promptly clean the equipment after usage, particularly the evaporation flask and condenser tube, to prevent residues from influencing subsequent usage.
11. Avoid overload: Do not surpass the maximum load of the equipment to prevent damage to the motor or impact the distillation efficiency.
12. Comply with regulations: Always adhere to the safety regulations and operating guidelines of the laboratory.
keyword:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Rotary Evaporator
- Subtitle: Rotary Evaporator
- Model: RRE-A,RRE-B,RRE-AC-A
- 全部型号: RRE-A-01,RRE-A-03,RRE-A-05,RRE-A-10,RRE-A-20,RRE-A-30,RRE-A-50,RRE-B-01A,RRE-B-01B,RRE-B-01C,RRE-B-05,RRE-B-10,RRE-B-20,RRE-B-50,RRE-AC-A-01,Distillation rotary evaporator
Rotary evaporator is a kind of laboratory equipment, which is employed for the continuous distillation of a large amount of volatile solvents under reduced pressure conditions.
Rotary evaporator is a kind of laboratory equipment, which is employed for the continuous distillation of a large amount of volatile solvents under reduced pressure conditions. By rotating the evaporation flask, it increases the surface area of the liquid and accelerates the evaporation rate. The device is usually furnished with a heating bath, vacuum pump and condenser, capable of efficiently recovering the solvents. With simple operation, it is extensively applied in domains such as chemistry and food science for operations like sample concentration and solvent removal, and is an indispensable tool in both scientific research and industrial production.
-
1. The water tank is fabricated from cylindrical stainless steel: The water tank is constructed with cylindrical stainless steel, featuring strong anti-corrosion capability and a long service life. The heating tank is capable of vertical movement, and the bath pot is intelligently temperature-controlled with digital display.
2. Digital constant temperature control of the water bath pot: The temperature of the instrument is digitally indicated, with intelligent constant temperature control, and the rotational speed is stable, precise and reliable.
3. The instrument is composed of stainless steel and aluminum alloy components: A significant portion of the mechanical structure utilizes stainless steel and aluminum alloy components, and all the glass components are made of high-temperature-resistant high borosilicate glass.
4. Valve-type feeding tube: It enables continuous feeding for the convenience of customers, and the valve-type feeding tube is sheathed with polytetrafluoroethylene (PTFE) tubing. -



1. Inspect the equipment: Prior to utilization, examine the integrity of the equipment, encompassing sealing rings, glass components, and the vacuum pump, among others.
2. Prepare the sample: Guarantee that the sample quantity is appropriate, not exceeding half of the capacity of the evaporation flask to avert overflow.
3. Install accurately: Install the evaporation flask, condenser tube, and receiving flask correctly, ensuring tight sealing at the connection points.
4. Set the temperature: Establish an appropriate heating temperature based on the boiling point of the solvent to evade overheating.
5. Conduct vacuum operation: Initiate the vacuum pump and gradually decrease the system pressure to prevent sample splashing due to sudden pressure drops.
6. Monitor the process: Closely supervise the temperature, pressure, and solvent evaporation during the distillation process.
7. Avoid dry burning: Ensure that there is always solvent in the evaporation flask to prevent damage to the equipment caused by dry burning.
8. Safety protection: Adorn appropriate personal protective equipment when operating, such as laboratory safety glasses and gloves.
9. Shut down the equipment: Upon the conclusion of the experiment, turn off the heating first, then cease the operation of the vacuum pump, and ultimately switch off the power supply.
10. Clean and maintain: Promptly clean the equipment after usage, particularly the evaporation flask and condenser tube, to prevent residues from influencing subsequent usage.
11. Avoid overload: Do not surpass the maximum load of the equipment to prevent damage to the motor or impact the distillation efficiency.
12. Comply with regulations: Always adhere to the safety regulations and operating guidelines of the laboratory.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation