Glass Thermometer
GT-G

Brand:
RUISCI
-
Choice
- GT-G-1,0-50℃,30cm,5Pcs
- GT-G-2,0-100℃,30cm,5Pcs
- GT-G-3,-10+110℃,30cm,5Pcs
- GT-G-4,-50+50℃,30cm,5Pcs
- GT-G-5,-30+100℃,30cm,5Pcs
- GT-G-6,0-150℃,30cm,5Pcs
- GT-G-7,0-200℃,30cm,5Pcs
- GT-G-8,0-50℃,15cm,5Pcs
- GT-G-9,0-50℃,20cm,5Pcs
- GT-G-10,0-100℃,20cm,5Pcs
Inventory
2680
隐藏域元素占位
Overview
Glass thermometer is a kind of instrument that uses the thermal expansion and cold contraction characteristics of alcohol to measure temperature. It consists of a glass bubble containing alcohol, a capillary tube, a scale and a temperature scale. The working principle of an alcohol thermometer is based on the volume change of alcohol at different temperatures, and the temperature is read by observing the height of the alcohol in the capillary tube. When used, it should be ensured that the foam of the thermometer is in full contact with the object to be measured, and when reading the temperature, the line of sight should be flat with the liquid surface in the thermometer to ensure the accuracy of the reading.
Features
1. High Safety: Non-toxic and harmless, avoid heavy metal pollution, not easy to damage, reduce the use of risk applicability.
2. Wide Applicability: Low temperature measurement ability is strong, suitable for low temperature environment, widely used in a variety of experimental scenes and material economy of the measured object.
3. High Economy: Low manufacturing cost, cheap price, easy maintenance, reduce maintenance costs and complexity of environmental protection.
4. Automatic Rise and Fall: Rapid cooling, no need to shake, automatic temperature rise and fall.
5. The Reading is Clear: Usually the alcohol will be dyed red or blue, in order to clearly see the liquid level column on the scale background, easy to quickly and accurately read the temperature.
Technical data
Preparation before use
1.Calibration check: Ensure that the thermometer has been calibrated, can be compared with the standard thermometer or verified in the ice-water mixture, and the liquid column is stable near the 0℃ scale
2.Appearance inspection: carefully check whether the glass tube is cracked or damaged, whether the liquid column is continuous without bubbles, whether the scale is clear, and replace it immediately when abnormal.
3.Full contact: the vacuole is in full contact with the measured object, completely immersed in the liquid or gas and does not touch the container wall
4.Avoid violent vibration: to prevent glass tube rupture or liquid column fracture, to avoid liquid column bubbles.
5.Wait for stability: patiently wait for the liquid column to be stable and then read, adapt to the temperature change of the measured medium.
6.Avoid direct sunlight: to prevent the surface temperature rise or the glass tube heat uneven
7.Sight level: the eye is level with the liquid surface, and the scale on the upper or lower edge of the liquid column is accurately read.
8.Cleaning and maintenance: clean the surface in time, remove residue, gently wipe with a soft cloth or cotton swab dipped in alcohol.
9.Proper storage: stored in a dry, cool, ventilated place, flat or hanging, avoid squeezing or collision.
10.Regular calibration: regular calibration and maintenance, found liquid column fracture, scale ambiguity and other problems solved in time.
keyword:
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Glass Thermometer
- Subtitle: Glass Thermometer
- Model: GT-G
- 全部型号: GT-G-1,GT-G-2,GT-G-3,GT-G-4,GT-G-5,GT-G-6,GT-G-7,GT-G-8,GT-G-9,GT-G-10
Glass thermometer is a kind of instrument that uses the thermal expansion and cold contraction characteristics of alcohol to measure temperature.
Glass thermometer is a kind of instrument that uses the thermal expansion and cold contraction characteristics of alcohol to measure temperature. It consists of a glass bubble containing alcohol, a capillary tube, a scale and a temperature scale. The working principle of an alcohol thermometer is based on the volume change of alcohol at different temperatures, and the temperature is read by observing the height of the alcohol in the capillary tube. When used, it should be ensured that the foam of the thermometer is in full contact with the object to be measured, and when reading the temperature, the line of sight should be flat with the liquid surface in the thermometer to ensure the accuracy of the reading.
-
1. High Safety: Non-toxic and harmless, avoid heavy metal pollution, not easy to damage, reduce the use of risk applicability.
2. Wide Applicability: Low temperature measurement ability is strong, suitable for low temperature environment, widely used in a variety of experimental scenes and material economy of the measured object.
3. High Economy: Low manufacturing cost, cheap price, easy maintenance, reduce maintenance costs and complexity of environmental protection.
4. Automatic Rise and Fall: Rapid cooling, no need to shake, automatic temperature rise and fall.
5. The Reading is Clear: Usually the alcohol will be dyed red or blue, in order to clearly see the liquid level column on the scale background, easy to quickly and accurately read the temperature. -
Preparation before use
1.Calibration check: Ensure that the thermometer has been calibrated, can be compared with the standard thermometer or verified in the ice-water mixture, and the liquid column is stable near the 0℃ scale
2.Appearance inspection: carefully check whether the glass tube is cracked or damaged, whether the liquid column is continuous without bubbles, whether the scale is clear, and replace it immediately when abnormal.
3.Full contact: the vacuole is in full contact with the measured object, completely immersed in the liquid or gas and does not touch the container wall
4.Avoid violent vibration: to prevent glass tube rupture or liquid column fracture, to avoid liquid column bubbles.
5.Wait for stability: patiently wait for the liquid column to be stable and then read, adapt to the temperature change of the measured medium.
6.Avoid direct sunlight: to prevent the surface temperature rise or the glass tube heat uneven
7.Sight level: the eye is level with the liquid surface, and the scale on the upper or lower edge of the liquid column is accurately read.
8.Cleaning and maintenance: clean the surface in time, remove residue, gently wipe with a soft cloth or cotton swab dipped in alcohol.
9.Proper storage: stored in a dry, cool, ventilated place, flat or hanging, avoid squeezing or collision.
10.Regular calibration: regular calibration and maintenance, found liquid column fracture, scale ambiguity and other problems solved in time.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.