Cation Suppressor is a key component in ion chromatography systems, whose main function is to suppress the anions in the mobile phase to enhance the detection signal of cations.


Features:
1. By suppression technology, it can effectively remove conductive ions in the eluent, thereby reducing background conductivity and making the baseline more stable, providing better optimal conditions for subsequent ion detection, which helps to improve the sensitivity and accuracy of detection.
2. While reducing background conductivity, it can amplify the target cation signals, enabling clear detection and precise quantification of low-concentration cations, and achieving higher sensitivity and lower detection limits.
3. It has good resistance to high back pressure and can operate stably under high pressure, ensuring the smooth progress of the analysis process and enhancing the reliability and safety of the equipment.
4. It is compact in size, occupies little space, and is easy to install and integrate into existing ion chromatography systems without adding much space burden.

Technical data

Precautions:
1. Before use, ensure that there is liquid flowing through the suppressor to avoid idling, otherwise it may be damaged easily.
2. Carefully check the connection between the suppressor and the ion chromatography system to ensure that all interfaces are well sealed without leakage. At the same time, make sure the pipelines are unobstructed.
3. Before injection, the samples should be pretreated to remove heavy metals or organic solvents to prevent irreparable damage to the suppressor. Complex samples should be pre-treated appropriately before injection.
4. During operation, make sure the flow rate and pressure are within the recommended range to avoid damage to the suppressor caused by excessively high or low flow rate and pressure.
5. After analysis, it is advisable to flush the suppressor with deionized water for 5 to 10 minutes to remove residual inorganic salts. Especially when using carbonate eluent, if the machine is idle for more than one day, it is recommended to clean the suppressor and then remove it from the instrument, and seal it with a plug.
6. If the suppressor is not used for more than one week, it should be activated before use, which can be done by injecting an appropriate amount of deionized water. If it is not used for more than two weeks, it should be filled with water and sealed with a plug for storage. Before the next use, it should be activated by injecting water.
7. For long-term storage, to prevent the ion exchange membrane from dehydrating and being damaged, it is necessary to flush the suppressor with deionized water every two weeks or so for maintenance.
8. After continuous use for one week, reverse the polarity of the power supply connections to protect the suppressor.

keyword:

Previous:

Next:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Cation Suppressor
    • Subtitle: Cation Suppressor
    • Model: CC-A-01
    • 全部型号: Cation Suppressor. Eluent. Cationic suppressor. Self-Regenerating Chemical Suppressor,CC-A-01

    Cation Suppressor is a key component in ion chromatography systems, whose main function is to suppress the anions in the mobile phase to enhance the detection signal of cations.

    Cation Suppressor is a key component in ion chromatography systems, whose main function is to suppress the anions in the mobile phase to enhance the detection signal of cations.

  • Features:
    1. By suppression technology, it can effectively remove conductive ions in the eluent, thereby reducing background conductivity and making the baseline more stable, providing better optimal conditions for subsequent ion detection, which helps to improve the sensitivity and accuracy of detection.
    2. While reducing background conductivity, it can amplify the target cation signals, enabling clear detection and precise quantification of low-concentration cations, and achieving higher sensitivity and lower detection limits.
    3. It has good resistance to high back pressure and can operate stably under high pressure, ensuring the smooth progress of the analysis process and enhancing the reliability and safety of the equipment.
    4. It is compact in size, occupies little space, and is easy to install and integrate into existing ion chromatography systems without adding much space burden.

  • Precautions:
    1. Before use, ensure that there is liquid flowing through the suppressor to avoid idling, otherwise it may be damaged easily.
    2. Carefully check the connection between the suppressor and the ion chromatography system to ensure that all interfaces are well sealed without leakage. At the same time, make sure the pipelines are unobstructed.
    3. Before injection, the samples should be pretreated to remove heavy metals or organic solvents to prevent irreparable damage to the suppressor. Complex samples should be pre-treated appropriately before injection.
    4. During operation, make sure the flow rate and pressure are within the recommended range to avoid damage to the suppressor caused by excessively high or low flow rate and pressure.
    5. After analysis, it is advisable to flush the suppressor with deionized water for 5 to 10 minutes to remove residual inorganic salts. Especially when using carbonate eluent, if the machine is idle for more than one day, it is recommended to clean the suppressor and then remove it from the instrument, and seal it with a plug.
    6. If the suppressor is not used for more than one week, it should be activated before use, which can be done by injecting an appropriate amount of deionized water. If it is not used for more than two weeks, it should be filled with water and sealed with a plug for storage. Before the next use, it should be activated by injecting water.
    7. For long-term storage, to prevent the ion exchange membrane from dehydrating and being damaged, it is necessary to flush the suppressor with deionized water every two weeks or so for maintenance.
    8. After continuous use for one week, reverse the polarity of the power supply connections to protect the suppressor.