Anion Suppressor

Anion Suppressor

AK-A


RUISCI

Brand:

RUISCI


USD

2250

Untaxed

EXW factory


  • Click to select
    • AK-A-01,6 MPa
Quantity
-
+

Inventory

1

隐藏域元素占位


Anion Suppressor is a key device in ion chromatography analysis for enhancing detection sensitivity and selectivity, mainly used for the detection of anions.


Features:
1. Transforming the high-conductivity eluent into a low-conductivity weak acid or water significantly reduces the background conductivity, thereby enhancing the detection sensitivity.
2. Converting the cation of the analyte anion into H⁺ increases the conductivity signal of the transformed analyte ion, improving the detection sensitivity.
3. It has a high dynamic suppression capacity, capable of meeting the analysis requirements of samples with different concentrations.
4. The current range is wide with small increments, allowing for precise adjustment to accommodate different eluent concentrations and analytical conditions.
5. It is compatible with various brands and models of ion chromatographs.
6. It can withstand a certain degree of sample contamination, is not prone to clogging or damage, ensuring the stability and reliability of the analysis.
7. The design is compact, with a small volume, not taking up much space, and is convenient for installation and use.

Technical data

Precautions:
1. Ensure that the anion suppressor is correctly and tightly connected to the ion chromatography system, including connections with the chromatographic column, pump, and detector, etc., to avoid leakage and affect the accuracy of the analysis results.
2. Before turning on the suppressor current, make sure that the mobile phase is flowing through the suppressor; otherwise, it may damage the suppressor.
3. Before using the instrument, check the entire flow path for air bubbles. If any are found, remove them before connecting the chromatographic column to prevent air bubbles from entering the column.
4. For complex samples, use a dedicated pretreatment column to remove organic substances or metal ions before injection to avoid contamination or damage to the suppressor.
5. Maintain a stable flow rate and avoid excessively high or low flow rates.
7. Turn on the current knob when the anion eluent is flowing and turn the current knob off before the anion detection is complete and the pump is turned off.
8. Long-term use of high-concentration eluents may damage the sensitive components inside the suppressor. Therefore, after the experiment, run the system with a lower concentration eluent to protect the suppressor.
9. To ensure the long-term stability of the suppressor, check and calibrate the system before use to ensure its performance meets the standards.
10. After analysis, clean the suppressor with ultrapure water or an appropriate cleaning solution to remove residual inorganic salts and other impurities.
11. Keep the suppressor moist. If it is not used for a long time, the micro-membrane may dehydrate.
12. Unused suppressors should be moistened with ultrapure water once a week for maintenance. For used suppressors, regular cleaning and maintenance should also be carried out. Depending on the usage frequency and contamination level, appropriate cleaning solutions can be selected for soaking or rinsing.

keyword:

Anionic Suppressor

Anion Suppressor ,Eluent

Self-Regenerating Electrolytic Micro-Membrane Suppressor

Previous:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Anion Suppressor
    • Subtitle: Anion Suppressor
    • Model: AK-A
    • 全部型号: Anion Suppressor ,Eluent. Anionic Suppressor. Self-Regenerating Electrolytic Micro-Membrane Suppressor,AK-A-01

    Anion Suppressor is a key device in ion chromatography analysis for enhancing detection sensitivity and selectivity, mainly used for the detection of anions.

    Anion Suppressor is a key device in ion chromatography analysis for enhancing detection sensitivity and selectivity, mainly used for the detection of anions.

  • Features:
    1. Transforming the high-conductivity eluent into a low-conductivity weak acid or water significantly reduces the background conductivity, thereby enhancing the detection sensitivity.
    2. Converting the cation of the analyte anion into H⁺ increases the conductivity signal of the transformed analyte ion, improving the detection sensitivity.
    3. It has a high dynamic suppression capacity, capable of meeting the analysis requirements of samples with different concentrations.
    4. The current range is wide with small increments, allowing for precise adjustment to accommodate different eluent concentrations and analytical conditions.
    5. It is compatible with various brands and models of ion chromatographs.
    6. It can withstand a certain degree of sample contamination, is not prone to clogging or damage, ensuring the stability and reliability of the analysis.
    7. The design is compact, with a small volume, not taking up much space, and is convenient for installation and use.

  • Precautions:
    1. Ensure that the anion suppressor is correctly and tightly connected to the ion chromatography system, including connections with the chromatographic column, pump, and detector, etc., to avoid leakage and affect the accuracy of the analysis results.
    2. Before turning on the suppressor current, make sure that the mobile phase is flowing through the suppressor; otherwise, it may damage the suppressor.
    3. Before using the instrument, check the entire flow path for air bubbles. If any are found, remove them before connecting the chromatographic column to prevent air bubbles from entering the column.
    4. For complex samples, use a dedicated pretreatment column to remove organic substances or metal ions before injection to avoid contamination or damage to the suppressor.
    5. Maintain a stable flow rate and avoid excessively high or low flow rates.
    7. Turn on the current knob when the anion eluent is flowing and turn the current knob off before the anion detection is complete and the pump is turned off.
    8. Long-term use of high-concentration eluents may damage the sensitive components inside the suppressor. Therefore, after the experiment, run the system with a lower concentration eluent to protect the suppressor.
    9. To ensure the long-term stability of the suppressor, check and calibrate the system before use to ensure its performance meets the standards.
    10. After analysis, clean the suppressor with ultrapure water or an appropriate cleaning solution to remove residual inorganic salts and other impurities.
    11. Keep the suppressor moist. If it is not used for a long time, the micro-membrane may dehydrate.
    12. Unused suppressors should be moistened with ultrapure water once a week for maintenance. For used suppressors, regular cleaning and maintenance should also be carried out. Depending on the usage frequency and contamination level, appropriate cleaning solutions can be selected for soaking or rinsing.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Cation Suppressor

Price:

1950

USD

Delivery:

7 Days


Cation Suppressor is a key component in ion chromatography systems, whose main function is to suppress the anions in the mobile phase to enhance the detection signal of cations.

COD Digestion Device

Price:

873

USD

Delivery:

30 Days


The COD Digestion Device is an experimental equipment used for determining the Chemical Oxygen Demand (COD), widely applied in environmental monitoring, wastewater treatment, chemical and pharmaceutical industries, etc.

Laminar Flow Clean Bench

Price:

350

USD

Delivery:

30 Days


Laminar Flow Clean Bench is a local air purification device used in fields such as biology, chemistry, and pharmaceuticals.

Refrigerated And Heated Circulator Bath,2

Price:

392

USD

Delivery:

30 Days


Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities.

Refrigerated And Heated Circulator Bath,1

Price:

633

USD

Delivery:

30 Days


Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities.

Online consultation


Name:

Submit