Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Refrigerated And Heated Circulator Bath,1

Refrigerated And Heated Circulator Bath

RHC-A


RUISCI

Brand:

RUISCI


USD

633

Untaxed

EXW factory


  • Choice
    • RHC-A-01,0.8kW,Conventional
    • RHC-A-02,1.3kW,Conventional
    • RHC-A-03,2.1kW,Conventional
    • RHC-A-04,2.3kW,Conventional
    • RHC-A-05,2.9kW,Conventional
    • RHC-A-06,3.5kW,Conventional
    • RHC-A-07,0.9kW,Conventional
    • RHC-A-08,1.5kW,Conventional
    • RHC-A-09,2.2kW,Conventional
    • RHC-A-10,2.4kW,Conventional
    • RHC-A-11,1kW,Conventional
    • RHC-A-12,1.8kW,Conventional
    • RHC-A-13,2.3kW,Conventional
    • RHC-A-14,2.5kW,Conventional
    • RHC-A-15,1.5kW,Conventional
    • RHC-A-16,2kW,Conventional
    • RHC-A-17,2.4kW,Conventional
    • RHC-A-18,2.6kW,Conventional
    • RHC-A-19,1.7kW,Conventional
    • RHC-A-20,2.1kW,Conventional
    • RHC-A-21,2.5kW,Conventional
    • RHC-A-22,2.7kW,Conventional
    • RHC-A-01A,0.8kW,6L,High Precision(Benchtop)
    • RHC-A-02A,1.3kW,10L,High Precision(Benchtop)
    • RHC-A-03A,2.1kW,15L,High Precision(Benchtop)
    • RHC-A-04A,2.1kW,20L,High Precision(Benchtop)
    • RHC-A-05A,0.9kW,6L,High Precision(Benchtop)
    • RHC-A-06A,1.5kW,10L,High Precision(Benchtop)
    • RHC-A-07A,2.2kW,15L,High Precision(Benchtop)
    • RHC-A-08A,2.2kW,20L,High Precision(Benchtop)
    • RHC-A-09A,1kW,6L,High Precision(Benchtop)
    • RHC-A-10A,1.8kW,10L,High Precision(Benchtop)
    • RHC-A-11A,2.3kW,15L,High Precision(Benchtop)
    • RHC-A-12A,2.3kW,20L,High Precision(Benchtop)
    • RHC-A-13A,1.5kW,6L,High Precision(Benchtop)
    • RHC-A-14A,2kW,10L,High Precision(Benchtop)
    • RHC-A-15A,2.4kW,15L,High Precision(Benchtop)
    • RHC-A-16A,2.6kW,20L,High Precision(Benchtop)
    • RHC-A-17A,2.1kW,6L,High Precision(Benchtop)
    • RHC-A-18A,2.1kW,10L,High Precision(Benchtop)
    • RHC-A-19A,2.5kW,15L,High Precision(Benchtop)
    • RHC-A-20A,2.7kW,20L,High Precision(Benchtop)
Quantity
-
+

Inventory

5082

隐藏域元素占位


Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities. Through the refrigeration system, it can transfer heat from low-temperature regions to high-temperature regions, attaining the refrigeration effect; whereas the heating system can convert electrical energy into heat energy, rapidly increasing the temperature. It is extensively applied in domains such as laboratories and industrial production, and can precisely control the temperature to ensure the stable advancement of experiments or production processes.


1. Intelligent PID Control Unit: The PID temperature control system can be automatically searched or manually adjusted, featuring stronger temperature stability. The temperature correction function can reach 0.01 ℃.
2. PT100 Temperature Sensor: The heating tube is fabricated from SUS304 stainless steel, and the PT100 three-wire system ensures more accurate temperature measurement.
3. Copper Core Motor Circulation Pump: The pure copper core motor, with rotor processed by CNC gear grinding, enables rapid circulation, is stable and low-noise, effectively guaranteeing temperature uniformity.
4. Internal Circulation Mode: Connecting the water inlet and outlet of the thermostatic bath with a single hose is termed as internal circulation.
5. External Circulation Mode: External circulation can extract the constant-temperature liquid within the bath to the exterior to establish a second constant-temperature field. It can also serve as a cold source to guide the refrigerated liquid inside the bath to the external experimental container for easier cooling.

Technical data

 

Working Environment Conditions:
1. Adequate Ventilation: Ensure a free flow of air around the equipment to avoid heat accumulation.
2. Absence of Corrosive Gases: Avoid usage in environments containing corrosive gases such as acids and alkalis to prevent equipment damage.
3. Free from Strong Electromagnetic Interference: Stay away from strong electromagnetic fields to evade influencing the electrical system of the equipment.
4. Flat and Stable Ground: The ground where the equipment is placed should be level and stable to prevent the equipment from tilting or swaying.
5. Stable Power Supply: Provide a stable power supply that complies with the equipment's requirements to avoid voltage fluctuations.
9. No Direct Sunlight Exposure: Prevent direct sunlight from shining on the equipment to avoid excessive surface temperature.

Precautions:
1. Equipment Inspection: Before usage, check whether all components are intact, and verify that the liquid level and air pressure are normal.
2. Grounding Safety: Ensure reliable grounding of the power supply. Do not operate when hands are moist.
3. Stable Placement: After adding liquid, avoid transporting or tilting the equipment. When discharging liquid, it should be conducted at room temperature.
4. Medium Selection: Utilize a heat transfer medium that is non-corrosive, non-flammable, non-explosive, and non-volatile.
5. Protecting the Circulation Pump: Do not activate the circulation pump when there is no heat transfer medium.
6. Hose Inspection: Ensure that externally connected hoses are firmly attached and avoid sharp bends.
7. Fault Handling: In the event of equipment damage or leakage, disconnect the power supply prior to undertaking repairs.
8. Avoid Shaking: During usage, prevent the equipment from shaking or undergoing elevation and descent.

keyword:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Refrigerated And Heated Circulator Bath,1
    • Subtitle: Refrigerated And Heated Circulator Bath
    • Model: RHC-A
    • 全部型号: RHC-A-01,RHC-A-02,RHC-A-03,RHC-A-04,RHC-A-05,RHC-A-06,RHC-A-07,RHC-A-08,RHC-A-09,RHC-A-10,RHC-A-11,RHC-A-12,RHC-A-13,RHC-A-14,RHC-A-15,RHC-A-16,RHC-A-17,RHC-A-18,RHC-A-19,RHC-A-20,RHC-A-21,RHC-A-22,RHC-A-01A,RHC-A-02A,RHC-A-03A,RHC-A-04A,RHC-A-05A,RHC-A-06A,RHC-A-07A,RHC-A-08A,RHC-A-09A,RHC-A-10A,RHC-A-11A,RHC-A-12A,RHC-A-13A,RHC-A-14A,RHC-A-15A,RHC-A-16A,RHC-A-17A,RHC-A-18A,RHC-A-19A,RHC-A-20A

    Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities.

    Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities. Through the refrigeration system, it can transfer heat from low-temperature regions to high-temperature regions, attaining the refrigeration effect; whereas the heating system can convert electrical energy into heat energy, rapidly increasing the temperature. It is extensively applied in domains such as laboratories and industrial production, and can precisely control the temperature to ensure the stable advancement of experiments or production processes.

  • 1. Intelligent PID Control Unit: The PID temperature control system can be automatically searched or manually adjusted, featuring stronger temperature stability. The temperature correction function can reach 0.01 ℃.
    2. PT100 Temperature Sensor: The heating tube is fabricated from SUS304 stainless steel, and the PT100 three-wire system ensures more accurate temperature measurement.
    3. Copper Core Motor Circulation Pump: The pure copper core motor, with rotor processed by CNC gear grinding, enables rapid circulation, is stable and low-noise, effectively guaranteeing temperature uniformity.
    4. Internal Circulation Mode: Connecting the water inlet and outlet of the thermostatic bath with a single hose is termed as internal circulation.
    5. External Circulation Mode: External circulation can extract the constant-temperature liquid within the bath to the exterior to establish a second constant-temperature field. It can also serve as a cold source to guide the refrigerated liquid inside the bath to the external experimental container for easier cooling.

  •  

    Working Environment Conditions:
    1. Adequate Ventilation: Ensure a free flow of air around the equipment to avoid heat accumulation.
    2. Absence of Corrosive Gases: Avoid usage in environments containing corrosive gases such as acids and alkalis to prevent equipment damage.
    3. Free from Strong Electromagnetic Interference: Stay away from strong electromagnetic fields to evade influencing the electrical system of the equipment.
    4. Flat and Stable Ground: The ground where the equipment is placed should be level and stable to prevent the equipment from tilting or swaying.
    5. Stable Power Supply: Provide a stable power supply that complies with the equipment's requirements to avoid voltage fluctuations.
    9. No Direct Sunlight Exposure: Prevent direct sunlight from shining on the equipment to avoid excessive surface temperature.

    Precautions:
    1. Equipment Inspection: Before usage, check whether all components are intact, and verify that the liquid level and air pressure are normal.
    2. Grounding Safety: Ensure reliable grounding of the power supply. Do not operate when hands are moist.
    3. Stable Placement: After adding liquid, avoid transporting or tilting the equipment. When discharging liquid, it should be conducted at room temperature.
    4. Medium Selection: Utilize a heat transfer medium that is non-corrosive, non-flammable, non-explosive, and non-volatile.
    5. Protecting the Circulation Pump: Do not activate the circulation pump when there is no heat transfer medium.
    6. Hose Inspection: Ensure that externally connected hoses are firmly attached and avoid sharp bends.
    7. Fault Handling: In the event of equipment damage or leakage, disconnect the power supply prior to undertaking repairs.
    8. Avoid Shaking: During usage, prevent the equipment from shaking or undergoing elevation and descent.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Safety Cabinet

Price:

47

USD

Delivery:

7 Days


Safety Cabinets are specialized equipment employed for the storage of hazardous substances, chemicals, or significant items, typically fabricated from fire-resistant, explosion-proof, and anti-corrosion materials.

Anti Slip Silicone Pad

Price:

6

USD

Delivery:

30 Days


The anti-slip silicone pad is an auxiliary tool, primarily fabricated from chemically-resistant silicone materials.

Chemical Absorbent Pads

Price:

3

USD

Delivery:

7 Days


Chemical Absorbent Pads are a kind of material specifically utilized for the adsorption of chemical liquids.

Laboratory Storage Cabinet

Price:

136

USD

Delivery:

7 Days


Laboratory storage cabinets constitute significant equipment within laboratories.

Refrigerated And Heated Circulator Bath,2

Price:

761

USD

Delivery:

30 Days


Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities.

Online consultation


Name:

Submit