Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

COD Digestion Device

COD Digestion

RCV-A


RUISCI

Brand:

RUISCI


USD

873

Untaxed

EXW factory


  • Click to select
    • RCV-A-01,8 Pcs
    • RCV-A-02,12 Pieces
Quantity
-
+

Inventory

196

隐藏域元素占位


The COD Digestion Device is an experimental equipment used for determining the Chemical Oxygen Demand (COD), widely applied in environmental monitoring, wastewater treatment, chemical and pharmaceutical industries, etc. It oxidizes organic matter in water samples into carbon dioxide and water through high-temperature digestion and chemical reactions, thereby measuring the COD value. This device adopts air-cooling technology instead of traditional water-cooling, which saves water and energy. It also features automatic temperature control and timing functions, is easy to operate and has high safety.


1. The heating unit of the black crystal glass adopts a new type of black crystal glass silver-coated conductive heating technology, which has an extremely long service life. It can withstand a temperature of 800℃. During heating, the surface of the electric furnace heats up evenly, and the heating and cooling speeds are fast.
2. The heating unit uses high-temperature resistant inorganic environmental protection insulation materials. The heat loss from the bottom plate and the periphery is small. The heating and heat conduction are uniform, and the thermal efficiency is higher.
3. The flat high-temperature resistant glass panel is flat, smooth and easy to clean. If the surface is contaminated, it can be wiped dry with a cloth, which can reduce the damage to the instrument caused by improper operation.
4. The upgraded glass reflux condenser with a thorn-like design and a heat dissipation system provides excellent digestion and reflux performance, ensuring the parallelism and accuracy of the sample digestion results.
5. According to the different heating powers selected by the user, the surface heating temperature of the electric furnace can be displayed.
6. The digestion time can be set. After digestion is completed, the instrument automatically stops heating. The instrument fan continues to work for half an hour to assist in cooling the sample, which can be left unattended.
7. It saves electricity and water, is safe and reliable, and improves the working efficiency of the operator.

Technical data

Precautions:
1. Check the equipment status before use: Inspect the power cord, digestion tubes, and heating module to ensure they are in good condition and free from damage or leakage to prevent safety hazards.
2. Confirm the compatibility of reagents and samples: Use freshly prepared reagents and ensure their type and concentration match the instrument model and detection method to avoid corrosion or abnormal reactions.
3. Accurately add samples and reagents: Use precise pipetting tools to add samples and reagents according to standards to avoid volume errors that could affect COD results.
4. Thoroughly mix before digestion: After adding concentrated sulfuric acid and other reagents, shake well to prevent violent local reactions that could cause boiling over or tube breakage.
5. Do not open the lid during digestion: To avoid heat loss, temperature fluctuations, and the leakage of harmful gases, ensuring experimental safety and data accuracy.
6. Wear personal protective equipment: Including heat-resistant gloves, goggles, and lab coats to prevent injury from high temperatures and corrosive reagents.
7. Dispose of waste liquids properly: Waste liquids containing potassium dichromate, mercury sulfate, etc., are hazardous waste and must be collected centrally and handed over to professional institutions for treatment; direct dumping is strictly prohibited.
8. Clean and maintain the equipment promptly after use: Clean the digestion tubes immediately after cooling to avoid residual contamination; regularly inspect the heating module, temperature sensor, and other components to extend the equipment's lifespan.

keyword:

COD Heater

COD Reactor

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: COD Digestion Device
    • Subtitle: COD Digestion
    • Model: RCV-A
    • 全部型号: COD Heater,COD Reactor,

    The COD Digestion Device is an experimental equipment used for determining the Chemical Oxygen Demand (COD), widely applied in environmental monitoring, wastewater treatment, chemical and pharmaceutical industries, etc.

    The COD Digestion Device is an experimental equipment used for determining the Chemical Oxygen Demand (COD), widely applied in environmental monitoring, wastewater treatment, chemical and pharmaceutical industries, etc. It oxidizes organic matter in water samples into carbon dioxide and water through high-temperature digestion and chemical reactions, thereby measuring the COD value. This device adopts air-cooling technology instead of traditional water-cooling, which saves water and energy. It also features automatic temperature control and timing functions, is easy to operate and has high safety.

  • 1. The heating unit of the black crystal glass adopts a new type of black crystal glass silver-coated conductive heating technology, which has an extremely long service life. It can withstand a temperature of 800℃. During heating, the surface of the electric furnace heats up evenly, and the heating and cooling speeds are fast.
    2. The heating unit uses high-temperature resistant inorganic environmental protection insulation materials. The heat loss from the bottom plate and the periphery is small. The heating and heat conduction are uniform, and the thermal efficiency is higher.
    3. The flat high-temperature resistant glass panel is flat, smooth and easy to clean. If the surface is contaminated, it can be wiped dry with a cloth, which can reduce the damage to the instrument caused by improper operation.
    4. The upgraded glass reflux condenser with a thorn-like design and a heat dissipation system provides excellent digestion and reflux performance, ensuring the parallelism and accuracy of the sample digestion results.
    5. According to the different heating powers selected by the user, the surface heating temperature of the electric furnace can be displayed.
    6. The digestion time can be set. After digestion is completed, the instrument automatically stops heating. The instrument fan continues to work for half an hour to assist in cooling the sample, which can be left unattended.
    7. It saves electricity and water, is safe and reliable, and improves the working efficiency of the operator.

  • Precautions:
    1. Check the equipment status before use: Inspect the power cord, digestion tubes, and heating module to ensure they are in good condition and free from damage or leakage to prevent safety hazards.
    2. Confirm the compatibility of reagents and samples: Use freshly prepared reagents and ensure their type and concentration match the instrument model and detection method to avoid corrosion or abnormal reactions.
    3. Accurately add samples and reagents: Use precise pipetting tools to add samples and reagents according to standards to avoid volume errors that could affect COD results.
    4. Thoroughly mix before digestion: After adding concentrated sulfuric acid and other reagents, shake well to prevent violent local reactions that could cause boiling over or tube breakage.
    5. Do not open the lid during digestion: To avoid heat loss, temperature fluctuations, and the leakage of harmful gases, ensuring experimental safety and data accuracy.
    6. Wear personal protective equipment: Including heat-resistant gloves, goggles, and lab coats to prevent injury from high temperatures and corrosive reagents.
    7. Dispose of waste liquids properly: Waste liquids containing potassium dichromate, mercury sulfate, etc., are hazardous waste and must be collected centrally and handed over to professional institutions for treatment; direct dumping is strictly prohibited.
    8. Clean and maintain the equipment promptly after use: Clean the digestion tubes immediately after cooling to avoid residual contamination; regularly inspect the heating module, temperature sensor, and other components to extend the equipment's lifespan.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


High Pressure Digestion Tank

Price:

42

USD

Delivery:

7 Days


High Pressure Digestion Tank is a kind of laboratory equipment for sample pretreatment, which is mainly used for chemical analysis and material research.

Microwave Digestion System

Price:

1730

USD

Delivery:

30 Days


The Microwave Digestion System is an analytical pretreatment apparatus that utilizes microwave energy to heat and digest samples within a sealed container.

Graphite Digestion Instrument

Price:

1216

USD

Delivery:

30 Days


The Graphite Digestion Instrument is a device commonly utilized in the domain of chemical analysis.

Laminar Flow Clean Bench

Price:

350

USD

Delivery:

30 Days


Laminar Flow Clean Bench is a local air purification device used in fields such as biology, chemistry, and pharmaceuticals.

Refrigerated And Heated Circulator Bath,2

Price:

392

USD

Delivery:

30 Days


Refrigerated And Heated Circulator is a multifunctional device capable of concurrently realizing both refrigeration and heating capabilities.

Online consultation


Name:

Submit