Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Graphite Digestion Instrument
Graphite Digestion Instrument
RGRD-A

Brand:
RUISCI
-
Choice
- RGRD-A-01,6Hole
- RGRD-A-02,12Hole
- RGRD-A-03,24Hole
- RGRD-A-04,48Hole
- RGRD-A-05,60Hole
Inventory
840
隐藏域元素占位
Overview
The Graphite Digestion Instrument is a device commonly utilized in the domain of chemical analysis. It is primarily employed in the digestion process of samples, decomposing organic or inorganic substances within the samples under high-temperature and acidic or alkaline conditions to facilitate subsequent elemental analysis or other detections. It can also be paired with a microwave digestion instrument for the pretreatment before microwave digestion or for acid expelling after digestion, and it is an ideal complementary product for analytical instruments such as atomic absorption, atomic fluorescence, and ICP-AES.
Features
1. Energy-saving and highly efficient: It employs a distinctive heating and insulation mode, achieving energy savings of over 30% compared with similar products.
2. Intelligent adjustment: It is furnished with an intelligent adjustment system featuring self-tuning functionality, guaranteeing precise temperature control and safe utilization.
3. Anti-corrosion design: The graphite surface layer is treated with Teflon, which is resistant to strong acids and strong alkalis, preventing corrosion of the machine's surface during experiments.
4. Uniform heating: The use of isostatic high-purity and ultra-fine graphite with excellent thermal conductivity ensures uniform temperature among all digestion holes, with a small temperature difference between the holes.
5. Double-layer inner liner suspended structure: Optimizes heat dissipation and avoids excessive heating of the chassis during prolonged usage.
6. Multiple protections: The equipment is equipped with multiple protections such as overvoltage, overcurrent, and overheating, as well as an over-temperature alarm function.
7. Safe, reliable, and simple to operate: The design takes into account humanization, automation, and safety, making the operation more straightforward, convenient, and rapid.
8. Customization support: The number of holes, hole depth, and hole diameter can be customized in accordance with requirements.
Technical data
Environmental Requirements:
• Temperature: The temperature of the working environment should be controlled within the range of 20°C to +25°C to guarantee the normal operation of the instrument.
• Humidity: The relative humidity of the air should be less than 75% to avoid dampness of the instrument.
• Ventilation: The machine should be placed in a dry and well-ventilated environment.
• Avoidance of vibration and electromagnetic interference: The working site should be free from intense vibration and kept away from strong electromagnetic field interference to ensure the safety of the experiment and the accuracy of the data.
• Power supply: Utilize a dedicated and independent power socket, and match the corresponding power and capacity in accordance with the usage power of the product. Meanwhile, a sound safety protection grounding should be provided to prevent any unexpected incidents.
Precautions:
1. Equipment inspection: Prior to usage, examine whether the instrument instrument is intact. Check if components such as the power cord, heating elements, and temperature control system are functioning properly.
2. Protective equipment donning: Appropriate personal protective equipment, including laboratory safety glasses, gloves, and laboratory gowns, should be worn during operation to prevent injuries from acid mist and high temperatures.
3. Sample preparation: Ensure the samples are prepared accurately. Avoid excessive or insufficient sample amountsto avoid affecting the experimental results or damaging the equipment
4. Temperature setting: Set the temperature accurately in accordance with the experimental requirements. Avoid overly high or low temperature settings to prevent effects on the experimental results or equipment damage.
5. Process monitoring: Monitor the working status of the equipment regularly, including temperature and pressure, to ensure the stability of the experimental process.
6. Overload prevention: Do not exceed the maximum sample processing capacity of the instrument instrument to avoid equipment overload.
7. Cleaning and maintenance: After the experiment, clean the instrument promptly, especially the heating holes and internal surfaces, to prevent the accumulation of residues that may affect subsequent usage.
8. Professional training: Operators should undergo professional training on the operation of the instrument instrument to ensure correct and safe usage.
keyword:
Graphite Digestion Apparatus
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Graphite Digestion Instrument
- Subtitle: Graphite Digestion Instrument
- Model: RGRD-A
- 全部型号: Graphite Digestion Apparatus,RGRD-A-01,RGRD-A-02,RGRD-A-03,RGRD-A-04,RGRD-A-05
The Graphite Digestion Instrument is a device commonly utilized in the domain of chemical analysis.
The Graphite Digestion Instrument is a device commonly utilized in the domain of chemical analysis. It is primarily employed in the digestion process of samples, decomposing organic or inorganic substances within the samples under high-temperature and acidic or alkaline conditions to facilitate subsequent elemental analysis or other detections. It can also be paired with a microwave digestion instrument for the pretreatment before microwave digestion or for acid expelling after digestion, and it is an ideal complementary product for analytical instruments such as atomic absorption, atomic fluorescence, and ICP-AES.
-
1. Energy-saving and highly efficient: It employs a distinctive heating and insulation mode, achieving energy savings of over 30% compared with similar products.
2. Intelligent adjustment: It is furnished with an intelligent adjustment system featuring self-tuning functionality, guaranteeing precise temperature control and safe utilization.
3. Anti-corrosion design: The graphite surface layer is treated with Teflon, which is resistant to strong acids and strong alkalis, preventing corrosion of the machine's surface during experiments.
4. Uniform heating: The use of isostatic high-purity and ultra-fine graphite with excellent thermal conductivity ensures uniform temperature among all digestion holes, with a small temperature difference between the holes.
5. Double-layer inner liner suspended structure: Optimizes heat dissipation and avoids excessive heating of the chassis during prolonged usage.
6. Multiple protections: The equipment is equipped with multiple protections such as overvoltage, overcurrent, and overheating, as well as an over-temperature alarm function.
7. Safe, reliable, and simple to operate: The design takes into account humanization, automation, and safety, making the operation more straightforward, convenient, and rapid.
8. Customization support: The number of holes, hole depth, and hole diameter can be customized in accordance with requirements. -
Environmental Requirements:
• Temperature: The temperature of the working environment should be controlled within the range of 20°C to +25°C to guarantee the normal operation of the instrument.
• Humidity: The relative humidity of the air should be less than 75% to avoid dampness of the instrument.
• Ventilation: The machine should be placed in a dry and well-ventilated environment.
• Avoidance of vibration and electromagnetic interference: The working site should be free from intense vibration and kept away from strong electromagnetic field interference to ensure the safety of the experiment and the accuracy of the data.
• Power supply: Utilize a dedicated and independent power socket, and match the corresponding power and capacity in accordance with the usage power of the product. Meanwhile, a sound safety protection grounding should be provided to prevent any unexpected incidents.Precautions:
1. Equipment inspection: Prior to usage, examine whether the instrument instrument is intact. Check if components such as the power cord, heating elements, and temperature control system are functioning properly.
2. Protective equipment donning: Appropriate personal protective equipment, including laboratory safety glasses, gloves, and laboratory gowns, should be worn during operation to prevent injuries from acid mist and high temperatures.
3. Sample preparation: Ensure the samples are prepared accurately. Avoid excessive or insufficient sample amountsto avoid affecting the experimental results or damaging the equipment
4. Temperature setting: Set the temperature accurately in accordance with the experimental requirements. Avoid overly high or low temperature settings to prevent effects on the experimental results or equipment damage.
5. Process monitoring: Monitor the working status of the equipment regularly, including temperature and pressure, to ensure the stability of the experimental process.
6. Overload prevention: Do not exceed the maximum sample processing capacity of the instrument instrument to avoid equipment overload.
7. Cleaning and maintenance: After the experiment, clean the instrument promptly, especially the heating holes and internal surfaces, to prevent the accumulation of residues that may affect subsequent usage.
8. Professional training: Operators should undergo professional training on the operation of the instrument instrument to ensure correct and safe usage.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation