Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Acid Evaporator

Acid Evaporator

RAE-A,RAE-B


RUISCI

Brand:

RUISCI


USD

1730

Untaxed

EXW factory


  • Choice
    • RAE-A-01,12(mini)Hole,Regular
    • RAE-A-02,12Hole,Regular
    • RAE-A-03,20Hole,Regular
    • RAE-A-04,56Hole,Regular
    • RAE-B-01,12Hole,Smart
    • RAE-B-02,24Hole,Smart
    • RAE-B-03,48Hole,Smart
    • RAE-B-04,60Hole,Smart
Quantity
-
+

Inventory

1344

隐藏域元素占位


The Acid Evaporator is a dedicated sample pretreatment apparatus employed in laboratories. Its principal role is to, subsequent to the completion of sample digestion, eliminate the acid in the digestion liquid through means such as heating, thereby reducing the acid concentration in the digestion liquid. This is done to fulfill the requirements of subsequent analytical tests and to prevent high-concentration acids from causing corrosion to analytical instruments or interfering with the analytical outcomes.


1. Intelligent temperature control with stable speed.
2. Resistant to high temperatures, corrosion, and easy to clean.
3. Multi-hole surround heating ensures uniform heat exposure, prevents heat dissipation, and enables rapid defrosting.
4. Over-temperature protection for safety and reliability.
5. The intelligent version employs a 4.3-inch LCD touchscreen, facilitating more convenient and rapid operation.

Technical data

Environmental Requirements:
• Temperature: The temperature of the working environment should be controlled within the range of -10°C to +70°C to guarantee the normal operation of the instrument.
• Humidity: The relative humidity of the air should be less than 90% to avoid dampness of the instrument.
• Ventilation: The machine should be placed in a dry and well-ventilated environment.
• Avoidance of vibration and electromagnetic interference: The working site should be free from intense vibration and kept away from strong electromagnetic field interference to ensure the safety of the experiment and the accuracy of the data.
• Power supply: Utilize a dedicated and independent power socket, and match the corresponding power and capacity in accordance with the usage power of the product. Meanwhile, a sound safety protection grounding should be provided to prevent any unexpected incidents.
Precautions:
1. Equipment inspection: Prior to usage, examine whether the instrument instrument is intact. Check if components such as the power cord, heating elements, and temperature control system are functioning properly.
2. Protective equipment donning: Appropriate personal protective equipment, including laboratory safety glasses, gloves, and laboratory gowns, should be worn during operation to prevent injuries from acid mist and high temperatures.
3. Sample preparation: Ensure the samples are prepared accurately. Avoid excessive or insufficient sample amounts to prevent impacts on the acid-expelling effect or equipment damage.
4. Temperature setting: Set the temperature accurately in accordance with the experimental requirements. Avoid overly high or low temperature settings to prevent effects on the experimental results or equipment damage.
5. Process monitoring: During the acid-expelling process, monitor the working status of the equipment regularly, including temperature and pressure, to ensure the stability of the experimental process.
6. Overload prevention: Do not exceed the maximum sample processing capacity of the instrument instrument to avoid equipment overload.
7. Cleaning and maintenance: After the experiment, clean the instrument promptly, especially the heating holes and internal surfaces, to prevent the accumulation of residues that may affect subsequent usage.
8. Professional training: Operators should undergo professional training on the operation of the instrument instrument to ensure correct and safe usage.

keyword:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Acid Evaporator
    • Subtitle: Acid Evaporator
    • Model: RAE-A,RAE-B
    • 全部型号: RAE-A-01,RAE-A-02,RAE-A-03,RAE-A-04,RAE-B-01,RAE-B-02,RAE-B-03,RAE-B-04

    The Acid Evaporator is a dedicated sample pretreatment apparatus employed in laboratories.

    The Acid Evaporator is a dedicated sample pretreatment apparatus employed in laboratories. Its principal role is to, subsequent to the completion of sample digestion, eliminate the acid in the digestion liquid through means such as heating, thereby reducing the acid concentration in the digestion liquid. This is done to fulfill the requirements of subsequent analytical tests and to prevent high-concentration acids from causing corrosion to analytical instruments or interfering with the analytical outcomes.

  • 1. Intelligent temperature control with stable speed.
    2. Resistant to high temperatures, corrosion, and easy to clean.
    3. Multi-hole surround heating ensures uniform heat exposure, prevents heat dissipation, and enables rapid defrosting.
    4. Over-temperature protection for safety and reliability.
    5. The intelligent version employs a 4.3-inch LCD touchscreen, facilitating more convenient and rapid operation.

  • Environmental Requirements:
    • Temperature: The temperature of the working environment should be controlled within the range of -10°C to +70°C to guarantee the normal operation of the instrument.
    • Humidity: The relative humidity of the air should be less than 90% to avoid dampness of the instrument.
    • Ventilation: The machine should be placed in a dry and well-ventilated environment.
    • Avoidance of vibration and electromagnetic interference: The working site should be free from intense vibration and kept away from strong electromagnetic field interference to ensure the safety of the experiment and the accuracy of the data.
    • Power supply: Utilize a dedicated and independent power socket, and match the corresponding power and capacity in accordance with the usage power of the product. Meanwhile, a sound safety protection grounding should be provided to prevent any unexpected incidents.
    Precautions:
    1. Equipment inspection: Prior to usage, examine whether the instrument instrument is intact. Check if components such as the power cord, heating elements, and temperature control system are functioning properly.
    2. Protective equipment donning: Appropriate personal protective equipment, including laboratory safety glasses, gloves, and laboratory gowns, should be worn during operation to prevent injuries from acid mist and high temperatures.
    3. Sample preparation: Ensure the samples are prepared accurately. Avoid excessive or insufficient sample amounts to prevent impacts on the acid-expelling effect or equipment damage.
    4. Temperature setting: Set the temperature accurately in accordance with the experimental requirements. Avoid overly high or low temperature settings to prevent effects on the experimental results or equipment damage.
    5. Process monitoring: During the acid-expelling process, monitor the working status of the equipment regularly, including temperature and pressure, to ensure the stability of the experimental process.
    6. Overload prevention: Do not exceed the maximum sample processing capacity of the instrument instrument to avoid equipment overload.
    7. Cleaning and maintenance: After the experiment, clean the instrument promptly, especially the heating holes and internal surfaces, to prevent the accumulation of residues that may affect subsequent usage.
    8. Professional training: Operators should undergo professional training on the operation of the instrument instrument to ensure correct and safe usage.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Microwave Digestion System

Price:

13600

USD

Delivery:

30 Days


The Microwave Digestion System is an analytical pretreatment apparatus that utilizes microwave energy to heat and digest samples within a sealed container.

Graphite Digestion Instrument

Price:

1216

USD

Delivery:

30 Days


The Graphite Digestion Instrument is a device commonly utilized in the domain of chemical analysis.

High Pressure Digestion Tank

Price:

42

USD

Delivery:

7 Days


High Pressure Digestion Tank is a kind of laboratory equipment for sample pretreatment, which is mainly used for chemical analysis and material research.

Digital Pellet Press, Excluding Molds

Price:

894

USD

Delivery:

1 Month


The pressure gauge of the Digital Pellet Press employs a digital display screen. Through the intuitive presentation of key parameters, convenient operation, and data recording, it markedly improves the accuracy of the pelletizing process and the efficiency of experiments.

Digital Pellet Press( With protective housing), Excluding Molds

Price:

1219

USD

Delivery:

1 Month


Digital Pellet Press (With protective housing) incorporates digital display functionality and protective design. Not only can it visually display key parameters, but it also possesses high safety and stability, effectively guaranteeing experimental safety and maintaining a clean laboratory environment.

Online consultation


Name:

Submit