Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Programmable Power Supplies
Programmable Power Supplies
RPPS-A,RPPS-B

Brand:
RUISCI
-
Choice
- RPPS-A-01,0.6W
- RPPS-A-02,0.9W
- RPPS-A-03,1.2W
- RPPS-A-04,1.8W
- RPPS-A-05,2.4W
- RPPS-A-06,3W
- RPPS-A-07,3.6W
- RPPS-A-08,4.8W
- RPPS-A-09,6W
- RPPS-A-10,7.5W
- RPPS-A-11,10W
- RPPS-A-12,12W
- RPPS-A-13,12W
- RPPS-A-14,12W
- RPPS-A-15,15W
- RPPS-A-16,15W
- RPPS-A-17,15W
- RPPS-B-01,0.6W
- RPPS-B-02,0.9W
- RPPS-B-03,1.2W
- RPPS-B-04,1.8W
- RPPS-B-05,2.4W
- RPPS-B-06,3W
- RPPS-B-07,3.6W
- RPPS-B-08,4.8W
- RPPS-B-09,6W
- RPPS-B-10,7.5W
- RPPS-B-11,10W
- RPPS-B-12,12W
- RPPS-B-13,12W
- RPPS-B-14,12W
- RPPS-B-15,15W
- RPPS-B-16,15W
- RPPS-B-17,15W
Inventory
5712
隐藏域元素占位
Overview
Programmable Power Supplies are power supply devices that can provide a stable DC voltage output and be programmed to adjust the output voltage, current, and other parameters.
Features
1. High - gain amplification circuit, core components are all high quality to ensure stable and reliable long - term operation under full load conditions.
2. The panel comes with preset buttons and can be preset for voltage and current values.
3. The output can be set to automatically shut down when it reaches the set values for over-voltage, over-current, over-temperature, and short-circuit protection.
4. It is capable of reducing the voltage drop resulting from a relatively long output circuit and compensates for the voltage drop on the line.
5. It can be connected to a PC, forming an intelligent power supply system that can be monitored by the PC.
Technical data
Precautions:
1. Conduct a thorough inspection of the power supply for damage and ensure the wiring is secure and correct to prevent short circuits, soldering errors, and connection reversals. Pay particular attention to the positive and negative connections of the power supply to avoid damaging the equipment or load.
2. Before connecting the load, adjust the output voltage and current of the power supply to their minimum values.
3. It is strictly prohibited to operate the equipment beyond the rated voltage and current ranges. Doing so may damage to the equipment or lead to safety accidents.
4. When it becomes necessary to adjust the voltage or current, the load must be disconnected first.
5. If the load short-circuits or becomes overloaded, causing protection to activate, first disconnect the load. Then, press the "Reset" button or reopen the power supply. Finally, access the load after removing the fault.
6. Ensure that the power supply is operating in an environment with adequate ventilation , avoid using it for a long time in a high temperature environment, in order to prevent overheating and damage to the equipment due to poor heat dissipation. Regularly clean the surface of the equipment and cooling vents to prevent the accumulation of dust, which can impede the efficiency of heat dissipation.
7. Avoid frequently switching the power supply on and off because the internal circuitry experiences a certain amount of shock every time it is switched on or off, and frequent switching may shorten the power supply's service life.
8. After use, gradually adjust the output voltage and current to their minimum values before turning off the power switch. This sequence of operations helps to ensure the safety of both the equipment and the connected load.
9. After turning off the power supply, promptly disconnect the load from the power source. This action prevents the load from remaining energized, thereby eliminating potential safety risks to both the load and personnel in the vicinity.
10. Regular maintenance and cleaning of the power supply are essential to keep the equipment neat and in good condition. Use a clean, soft cloth to gently wipe the surface of the equipment and avoid cleaning agents containing corrosive substances.
11. When not in use for an extended period, store the power supply in a dry, well - ventilated environment free from corrosive gases. Protect the equipment from direct sunlight and moisture, and ensure that it is in the powered - off state. These storage conditions help to prevent damage and deterioration of the power supply over time.
keyword:
Programmable DC Regulated Power Supply
DC Power Supply Variable
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Programmable Power Supplies
- Subtitle: Programmable Power Supplies
- Model: RPPS-A,RPPS-B
- 全部型号: Programmable DC Regulated Power Supply. DC Power Supply Variable,RPPS-A-01,RPPS-A-02,RPPS-A-03,RPPS-A-04,RPPS-A-05,RPPS-A-06,RPPS-A-07,RPPS-A-08,RPPS-A-09,RPPS-A-10,RPPS-A-11,RPPS-A-12,RPPS-A-13,RPPS-A-14,RPPS-A-15,RPPS-A-16,RPPS-A-17,RPPS-B-01,RPPS-B-02,RPPS-B-03,RPPS-B-04,RPPS-B-05,RPPS-B-06,RPPS-B-07,RPPS-B-08,RPPS-B-09,RPPS-B-10,RPPS-B-12,RPPS-B-13,RPPS-B-14,RPPS-B-15,RPPS-B-16,RPPS-B-17
Programmable Power Supplies are power supply devices that can provide a stable DC voltage output and be programmed to adjust the output voltage, current, and other parameters.
Programmable Power Supplies are power supply devices that can provide a stable DC voltage output and be programmed to adjust the output voltage, current, and other parameters.
-
1. High - gain amplification circuit, core components are all high quality to ensure stable and reliable long - term operation under full load conditions.
2. The panel comes with preset buttons and can be preset for voltage and current values.
3. The output can be set to automatically shut down when it reaches the set values for over-voltage, over-current, over-temperature, and short-circuit protection.
4. It is capable of reducing the voltage drop resulting from a relatively long output circuit and compensates for the voltage drop on the line.
5. It can be connected to a PC, forming an intelligent power supply system that can be monitored by the PC. -
Precautions:
1. Conduct a thorough inspection of the power supply for damage and ensure the wiring is secure and correct to prevent short circuits, soldering errors, and connection reversals. Pay particular attention to the positive and negative connections of the power supply to avoid damaging the equipment or load.
2. Before connecting the load, adjust the output voltage and current of the power supply to their minimum values.
3. It is strictly prohibited to operate the equipment beyond the rated voltage and current ranges. Doing so may damage to the equipment or lead to safety accidents.
4. When it becomes necessary to adjust the voltage or current, the load must be disconnected first.
5. If the load short-circuits or becomes overloaded, causing protection to activate, first disconnect the load. Then, press the "Reset" button or reopen the power supply. Finally, access the load after removing the fault.
6. Ensure that the power supply is operating in an environment with adequate ventilation , avoid using it for a long time in a high temperature environment, in order to prevent overheating and damage to the equipment due to poor heat dissipation. Regularly clean the surface of the equipment and cooling vents to prevent the accumulation of dust, which can impede the efficiency of heat dissipation.
7. Avoid frequently switching the power supply on and off because the internal circuitry experiences a certain amount of shock every time it is switched on or off, and frequent switching may shorten the power supply's service life.
8. After use, gradually adjust the output voltage and current to their minimum values before turning off the power switch. This sequence of operations helps to ensure the safety of both the equipment and the connected load.
9. After turning off the power supply, promptly disconnect the load from the power source. This action prevents the load from remaining energized, thereby eliminating potential safety risks to both the load and personnel in the vicinity.
10. Regular maintenance and cleaning of the power supply are essential to keep the equipment neat and in good condition. Use a clean, soft cloth to gently wipe the surface of the equipment and avoid cleaning agents containing corrosive substances.
11. When not in use for an extended period, store the power supply in a dry, well - ventilated environment free from corrosive gases. Protect the equipment from direct sunlight and moisture, and ensure that it is in the powered - off state. These storage conditions help to prevent damage and deterioration of the power supply over time.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation