Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Automatic Blaine Air Permeability Tester
Automatic Blaine Air Permeability Tester
RABA-A

Brand:
RUISCI
-
Choice
- RABA-A-01,8~34℃
Inventory
297
隐藏域元素占位
Overview
The Automatic Blaine Air Permeability Tester incorporates high-reliability Microcontroller Unit and integrated circuits. With multiple anti-interference technologies implemented in both hardware and software, it features EEPROM for real-time data storage. The system eliminates human errors, delivering simple, accurate, fast, and convenient operation.
Features
1. With the exception of manual material loading, the entire experimental process is automatically executed, thereby effectively eliminating human errors.
2. One measurement result can be obtained by pressing the measurement button once.
3. Scope of application: It is applicable to the scope stipulated in GB8074 - 2008.
4. It has the capabilities of data retention during power suspension or outages, automatic timing, automatic temperature measurement, automatic water - level detection, automatic detection of the instrument's operating status, automatic result calculation and display, and full - fledged automatic measurement functions.
Technical data
Precautions:
1. It should be wiped frequently to keep it clean. When not in use, it should be stored in the box for future use.
2. The liquid level in the pressure gauge should be maintained at the specified height.
3. After the test, clean the permeability cell and the perforated plate and store them in the accessory box for future use.
4. Before the test, check whether the electromagnetic pump rotates normally. The negative pressure should be adjusted in advance to prevent accidental liquid aspiration into the electromagnetic pump. If liquid ingress occur, immediately initiate a dry-run operation for a period of time until the liquid is naturally drained before using it again.
keyword:
Automatic Blaine Apparatus Surface
Blaine Air Permeability Apparatus for Cement
Blaine Fineness Tester for Powder Materials
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Automatic Blaine Air Permeability Tester
- Subtitle: Automatic Blaine Air Permeability Tester
- Model: RABA-A
- 全部型号: Automatic Blaine Apparatus Surface,Blaine Air Permeability Apparatus for Cement,Blaine Fineness Tester for Powder Materials,RABA-A-01
The Automatic Blaine Air Permeability Tester incorporates high-reliability Microcontroller Unit and integrated circuits.
The Automatic Blaine Air Permeability Tester incorporates high-reliability Microcontroller Unit and integrated circuits. With multiple anti-interference technologies implemented in both hardware and software, it features EEPROM for real-time data storage. The system eliminates human errors, delivering simple, accurate, fast, and convenient operation.
-
1. With the exception of manual material loading, the entire experimental process is automatically executed, thereby effectively eliminating human errors.
2. One measurement result can be obtained by pressing the measurement button once.
3. Scope of application: It is applicable to the scope stipulated in GB8074 - 2008.
4. It has the capabilities of data retention during power suspension or outages, automatic timing, automatic temperature measurement, automatic water - level detection, automatic detection of the instrument's operating status, automatic result calculation and display, and full - fledged automatic measurement functions. -
Precautions:
1. It should be wiped frequently to keep it clean. When not in use, it should be stored in the box for future use.
2. The liquid level in the pressure gauge should be maintained at the specified height.
3. After the test, clean the permeability cell and the perforated plate and store them in the accessory box for future use.
4. Before the test, check whether the electromagnetic pump rotates normally. The negative pressure should be adjusted in advance to prevent accidental liquid aspiration into the electromagnetic pump. If liquid ingress occur, immediately initiate a dry-run operation for a period of time until the liquid is naturally drained before using it again.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation