High Performance Liquid Chromatography(HPLC)
High Performance Liquid Chromatography(HPLC)
RLC-A
Brand:
RUISCI
-
Click to select
- RLC-A-01,Isocratic Elution
- RLC-A-02,Gradient Elution
Inventory
318
隐藏域元素占位
Overview
High Performance Liquid Chromatography(HPLC) is an instrument used for the separation and analysis of components in complex samples, and is widely applied in fields such as medicine, food, and the environment. It achieves separation through the interaction between the mobile phase and the stationary phase.
Features
1. The Liquid Constant Flow Pump can be interfaced with any type of liquid detector, thus finding extensive applications in the field of high - performance liquid chromatography.
2.UV-Vis Spectrophotometric Detector: It conforms to GMP/GLP, ISO9001, and 21 CFR standards.
3.UV-Vis Spectrophotometric Detector: The unique flow cell design ensures the precision and sensitivity of the instrument.
Technical data

Precautions:
1. Sample preparation solubility: The sample must be completely dissolved in the mobile phase to avoid particles entering the chromatographic column.
2. Concentration: The sample concentration should not be too high to prevent overloading the chromatographic column.
3. Compatibility: Ensure that the mobile phase is compatible with the chromatographic column and detector.
4. Chromatographic column maintenance and installation: Install the chromatographic column correctly to avoid leakage or damage.
5. Equilibration: Equilibrate the chromatographic column with the mobile phase before use to avoid a decrease in column efficiency.
6. Avoid reverse flushing: Do not reverse flush the column unless permitted by the column manual.
7. Instrument operation preheating: Preheat the system for 30 minutes after startup to ensure stability.
8. Flow rate control: Set the appropriate flow rate according to the chromatographic column requirements to avoid being too high or too low.
9. Temperature control: Maintain a constant column temperature to avoid temperature fluctuations affecting separation efficiency.
10. Pressure monitoring: Regularly check the system pressure to avoid abnormal increases.
11. Detector usage calibration: Regularly calibrate the detector to ensure accuracy.
12. Maintenance: Regularly clean the detector window to avoid contamination affecting sensitivity.
13. Parameter setting: Set the appropriate detection wavelength or mode according to the analysis target.
14. Data processing and record: Record the experimental conditions and data in a timely manner.
15. Electrical safety: Ensure the instrument is properly grounded to prevent electric shock.
16. Daily maintenance and cleaning inspection: Regularly clean the instrument surface and components to prevent dust accumulation. Regularly check whether the tubing, joints, etc. are loose or damaged.
17. Common problem avoidance: Excessively high column pressure: It may be due to column head blockage or a flow rate set too high.
keyword:
Liquid Chromatography Systems
HPLC Machine,Analytical HPLC Equipment
Previous:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: High Performance Liquid Chromatography(HPLC)
- Subtitle: High Performance Liquid Chromatography(HPLC)
- Model: RLC-A
- 全部型号: RLC-A-01,RLC-A-02,Liquid Chromatography Systems,HPLC Machine,Analytical HPLC Equipment
High Performance Liquid Chromatography(HPLC) is an instrument used for the separation and analysis of components in complex samples, and is widely applied in fields such as medicine, food, and the environment.
High Performance Liquid Chromatography(HPLC) is an instrument used for the separation and analysis of components in complex samples, and is widely applied in fields such as medicine, food, and the environment. It achieves separation through the interaction between the mobile phase and the stationary phase.
-
1. The Liquid Constant Flow Pump can be interfaced with any type of liquid detector, thus finding extensive applications in the field of high - performance liquid chromatography.
2.UV-Vis Spectrophotometric Detector: It conforms to GMP/GLP, ISO9001, and 21 CFR standards.
3.UV-Vis Spectrophotometric Detector: The unique flow cell design ensures the precision and sensitivity of the instrument. -

Precautions:
1. Sample preparation solubility: The sample must be completely dissolved in the mobile phase to avoid particles entering the chromatographic column.
2. Concentration: The sample concentration should not be too high to prevent overloading the chromatographic column.
3. Compatibility: Ensure that the mobile phase is compatible with the chromatographic column and detector.
4. Chromatographic column maintenance and installation: Install the chromatographic column correctly to avoid leakage or damage.
5. Equilibration: Equilibrate the chromatographic column with the mobile phase before use to avoid a decrease in column efficiency.
6. Avoid reverse flushing: Do not reverse flush the column unless permitted by the column manual.
7. Instrument operation preheating: Preheat the system for 30 minutes after startup to ensure stability.
8. Flow rate control: Set the appropriate flow rate according to the chromatographic column requirements to avoid being too high or too low.
9. Temperature control: Maintain a constant column temperature to avoid temperature fluctuations affecting separation efficiency.
10. Pressure monitoring: Regularly check the system pressure to avoid abnormal increases.
11. Detector usage calibration: Regularly calibrate the detector to ensure accuracy.
12. Maintenance: Regularly clean the detector window to avoid contamination affecting sensitivity.
13. Parameter setting: Set the appropriate detection wavelength or mode according to the analysis target.
14. Data processing and record: Record the experimental conditions and data in a timely manner.
15. Electrical safety: Ensure the instrument is properly grounded to prevent electric shock.
16. Daily maintenance and cleaning inspection: Regularly clean the instrument surface and components to prevent dust accumulation. Regularly check whether the tubing, joints, etc. are loose or damaged.
17. Common problem avoidance: Excessively high column pressure: It may be due to column head blockage or a flow rate set too high.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation