Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Gas Chromatograph

Gas Chromatograph

RGD-A,RGD-GE-A


RUISCI

Brand:

RUISCI


USD

600

Untaxed

EXW factory


  • Click to select
    • RGD-A-01,Organic Solvents
    • RGD-A-02,Baijiu Analysis
    • RGD-A-03,Ethylene Oxide Analysis
    • RGD-A-04,Non-Methane Total Hydrocarbons Analysis
    • RGD-A-05,Ethylene Oxide Analysis
    • RGD-A-06,Gasoline Oxygenates
    • RGD-GE-A-01,Hydrogen Generator
    • RGD-GE-A-02,Air Generator
Quantity
-
+

Inventory

1136

隐藏域元素占位


Gas Chromatograph is an analytical instrument employed for the separation and analysis of volatile compounds. The separation is accomplished by introducing the sample into the analytical column via a carrier gas, followed by the detection of each component by a detector. It is widely used in fields such as petrochemicals, environmental protection, food safety, and medical and health.


1. The mainframe series of gas chromatographs is equipped with a fully microcomputerized key operation system and a 5.7 - inch large - screen liquid crystal display.
2. The mainframe of the gas chromatograph is built upon a newly integrated digital electronic circuit. It offers high - precision control, with stable and reliable performance. The high - precision temperature control system can perform 60 temperature - regulating operations per second, achieving an accuracy of up to 0.1 °C.
3. It incorporates functions such as an 18 - step programmed temperature increase, automatic rear - door opening for rapid cooling, operation near room temperature, six - channel temperature control, self - diagnostic function for faults, digital zero adjustment, and over - temperature alarm protection.

Technical data

Precautions:
1. Safety operation for fire and explosion prevention: Carrier gas and fuel gas (Such as hydrogen gas) are flammable and explosive. Avoid open flames and leaks.
2. Poison prevention: Wear protective gear (gloves, masks, goggles) during operation to avoid contact with toxic reagents.
3. Electrical safety: Ensure proper grounding of the instrument to prevent electrical faults.
4. Regular calibration and maintenance of the instrument: Regularly calibrate the instrument to ensure accurate performance and results.
5. Cleaning and maintenance: Regularly clean the instrument components to keep them in good condition.
6. Check the gas lines: Regularly inspect the gas lines to ensure there are no leaks.
7. Maintain the purifier: Regularly replace the gas purifier fill to ensure the purity of the carrier gas.
8. Sample preparation for analysis: Ensure the samples are clean. Solid or viscous samples should be processed into solutions.
9. Injection technique: Control the injection volume, avoid bubbles and leaks, and keep the injection needle clean.
10. Detector adjustment: Set the detector parameters according to the sample type.
11. Avoid vibration: Place the instrument on a stable platform to avoid vibration.

keyword:

Portable Gas Chromatograph Analyzer

Laboratory GC Machine

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Gas Chromatograph
    • Subtitle: Gas Chromatograph
    • Model: RGD-A,RGD-GE-A
    • 全部型号: RGD-A-01,RGD-A-02,RGD-A-03,RGD-A-04,RGD-A-05,RGD-A-06,RGD-GE-A-01,RGD-GE-A-02,Portable Gas Chromatograph Analyzer, Laboratory GC Machine

    Gas Chromatograph is an analytical instrument employed for the separation and analysis of volatile compounds.

    Gas Chromatograph is an analytical instrument employed for the separation and analysis of volatile compounds. The separation is accomplished by introducing the sample into the analytical column via a carrier gas, followed by the detection of each component by a detector. It is widely used in fields such as petrochemicals, environmental protection, food safety, and medical and health.

  • 1. The mainframe series of gas chromatographs is equipped with a fully microcomputerized key operation system and a 5.7 - inch large - screen liquid crystal display.
    2. The mainframe of the gas chromatograph is built upon a newly integrated digital electronic circuit. It offers high - precision control, with stable and reliable performance. The high - precision temperature control system can perform 60 temperature - regulating operations per second, achieving an accuracy of up to 0.1 °C.
    3. It incorporates functions such as an 18 - step programmed temperature increase, automatic rear - door opening for rapid cooling, operation near room temperature, six - channel temperature control, self - diagnostic function for faults, digital zero adjustment, and over - temperature alarm protection.

  • Precautions:
    1. Safety operation for fire and explosion prevention: Carrier gas and fuel gas (Such as hydrogen gas) are flammable and explosive. Avoid open flames and leaks.
    2. Poison prevention: Wear protective gear (gloves, masks, goggles) during operation to avoid contact with toxic reagents.
    3. Electrical safety: Ensure proper grounding of the instrument to prevent electrical faults.
    4. Regular calibration and maintenance of the instrument: Regularly calibrate the instrument to ensure accurate performance and results.
    5. Cleaning and maintenance: Regularly clean the instrument components to keep them in good condition.
    6. Check the gas lines: Regularly inspect the gas lines to ensure there are no leaks.
    7. Maintain the purifier: Regularly replace the gas purifier fill to ensure the purity of the carrier gas.
    8. Sample preparation for analysis: Ensure the samples are clean. Solid or viscous samples should be processed into solutions.
    9. Injection technique: Control the injection volume, avoid bubbles and leaks, and keep the injection needle clean.
    10. Detector adjustment: Set the detector parameters according to the sample type.
    11. Avoid vibration: Place the instrument on a stable platform to avoid vibration.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Bracket For Tensile And Compression Gauge

Price:

184

USD

Delivery:

30 Days


The Bracket For Tensile And Compression Gauge is a multifunctional mechanical property testing device, mainly used for conducting various mechanical property tests such as tension, compression, bending, and shearing on different materials or products.

High Performance Liquid Chromatography(HPLC)

Price:

11250

USD

Delivery:

30 Days


High Performance Liquid Chromatography(HPLC) is an instrument used for the separation and analysis of components in complex samples, and is widely applied in fields such as medicine, food, and the environment.

Laser Level

Price:

236

USD

Delivery:

30 Days


Laser Level is an instrument that uses laser technology to determine horizontal or vertical planes and is widely used in engineering construction, building construction, interior decoration and other fields.

Air Quality Detector

Price:

17

USD

Delivery:

30 Days


The Air Quality Detector is an instrument used for monitoring and analyzing the concentrations of various pollutants in the air.

Transformer Core Grounding Current Tester

Price:

442

USD

Delivery:

30 Days


The Transformer Core Grounding Current Tester is a specialized device used for measuring the grounding current of the transformer core and clamping components.

Online consultation


Name:

Submit