Overview
The Power Analyzer is a precise instrument used for measuring and analyzing power-related parameters in electrical systems. It is widely applied in power systems, electronic devices, motor drives, renewable energy, and other fields to evaluate and optimize the energy efficiency and performance of systems.
Features
Features:
1. Multi-parameter measurement
2. 8-inch large high-definition display screen
3. Multiple communication interfaces
4. Possesses the electrical energy integration measurement function. Four integration modes are available for selection (including normal integration, continuous integration, real-time integration, and real-time continuous integration). Supports independent channel integration and programmable integration time settings.
5. With a rugged design, it can operate stably in harsh environments.
Technical data
Precautions:
1. It is necessary to ensure that the instrument is placed in an environment that is dry, well - ventilated, and free from strong magnetic field interference. Direct sunlight and dust accumulation should be avoided.
2. Guarantee that both the instrument and the device under measurement are correctly grounded. This is to prevent electric shock hazards and damage to the equipment.
3. Prior to use, conduct a thorough inspection of the equipment. Check whether the external appearance is intact, the installation is secure, the wiring connections is correct, and the cables comply with safety standards.
4. Calibrate the power analyzer regularly to guarantee the accuracy of measurements. The calibration interval typically depends on the frequency of use and the working environment. Typically, it is advisable to perform calibration on an annual basis.
5. Routinely clean the exterior of the power analyzer, particularly components such as the cooling fan and heat sink and other parts, to prevent dust from accumulating and affecting the cooling effect.
6. Periodically examine the power cord, socket, and grounding device to ensure that they are free from damage and looseness.
7. When the instrument will not be used for an extended period, store it in a dry and well - ventilated location to avoid issues such as moisture absorption and corrosion.
keyword:
Power Analyzer
Multi-Channel Power Analyzer
Electrical Power Analyzer
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Power Analyzer
- Subtitle: Power Analyzer
- Model: RPAN-A
- 全部型号: Power Analyzer,Multi-Channel Power Analyzer,Electrical Power Analyzer,RPAN-A-01
The Power Analyzer is a precise instrument used for measuring and analyzing power-related parameters in electrical systems.
The Power Analyzer is a precise instrument used for measuring and analyzing power-related parameters in electrical systems. It is widely applied in power systems, electronic devices, motor drives, renewable energy, and other fields to evaluate and optimize the energy efficiency and performance of systems.
-
Features:
1. Multi-parameter measurement
2. 8-inch large high-definition display screen
3. Multiple communication interfaces
4. Possesses the electrical energy integration measurement function. Four integration modes are available for selection (including normal integration, continuous integration, real-time integration, and real-time continuous integration). Supports independent channel integration and programmable integration time settings.
5. With a rugged design, it can operate stably in harsh environments. -
Precautions:
1. It is necessary to ensure that the instrument is placed in an environment that is dry, well - ventilated, and free from strong magnetic field interference. Direct sunlight and dust accumulation should be avoided.
2. Guarantee that both the instrument and the device under measurement are correctly grounded. This is to prevent electric shock hazards and damage to the equipment.
3. Prior to use, conduct a thorough inspection of the equipment. Check whether the external appearance is intact, the installation is secure, the wiring connections is correct, and the cables comply with safety standards.
4. Calibrate the power analyzer regularly to guarantee the accuracy of measurements. The calibration interval typically depends on the frequency of use and the working environment. Typically, it is advisable to perform calibration on an annual basis.
5. Routinely clean the exterior of the power analyzer, particularly components such as the cooling fan and heat sink and other parts, to prevent dust from accumulating and affecting the cooling effect.
6. Periodically examine the power cord, socket, and grounding device to ensure that they are free from damage and looseness.
7. When the instrument will not be used for an extended period, store it in a dry and well - ventilated location to avoid issues such as moisture absorption and corrosion.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation