Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Cell Counter
Cell Counter
RCEC-A,RCEC-B

Brand:
RUISCI
-
Choice
- RCEC-A-01,Automated Cell Counters (Bright Field Model)
- RCEC-A-02,Automated Cell Counters (Fluorescence Model)
- RCEC-B-01,Automated Cell Counters
Inventory
522
隐藏域元素占位
Overview
The Cell Counter is a high-precision apparatus utilized for the rapid enumeration and analysis of cell specimens. Featuring automated operation, multiparameter analysis, and fluorescence detection capabilities, it is widely used in cell biology research, drug screening and related fields. This instrument serves as an essential tool in modern biological laboratories, utilizing automated processes and precision optical systems to deliver highly accurate and reproducible cell counting results, thereby enhancing experimental efficiency and ensuring reliable data outcomes.
Features
1. High-performance hardware and configuration: Rapid computation, smooth analysis, and intelligent analysis without lag.
2. RCEC-A precision counting with intelligent recognition algorithm: 6 megapixel high-definition imaging, supporting statistical analysis of 3 fields of view for each of 6 samples, ensuring accurate and stable counting results and precise segmentation of cell clusters.
3. USB configuration interface: The software is easy to operate and the data management is traceable.
4. RCEC-A intuitive interface: Fingertip touchscreen operation is simple and convenient. A variety of built-in visual data analysis image modes are available.
Technical data
Precautions:
1. The equipment should be placed on a dry, sturdy and stable surface.
2. To protect the equipment, keep it away from moisture, dust, smoke, and direct sunlight.
3. The operating temperature should range from 4℃ to 40℃.
4. Handle supporting reagents(e.g., Trypan Blue) in strict compliance with all applicable safety regulations.
5. Do not power on this equipment in low-temperature environment. If the equipment is accidentally placed in low-temperature environment, please transfer the equipment to room temperature and leave it for at least 2 hours before use.
6. The device must not be placed on vibrating laboratory bench—ensure the platform remains stable and level.
7. Only trained personnel may operate this equipment in properly managed laboratory settings. When handling samples, proper personal protective equipment must be worn, especially gloves.
8. During fluorescence experiments, do not look directly into the sample inlet and the ventilation openings of the equipment.
keyword:
Automated Cell Counters
Brightfield Cell Counter
Fluorescence Cell Counter
Lab Cell Counter
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Cell Counter
- Subtitle: Cell Counter
- Model: RCEC-A,RCEC-B
- 全部型号: Automated Cell Counters,Brightfield Cell Counter,Fluorescence Cell Counter,Lab Cell Counter,RCEC-A-01,RCEC-A-02,RCEC-B-01
The Cell Counter is a high-precision apparatus utilized for the rapid enumeration and analysis of cell specimens.
The Cell Counter is a high-precision apparatus utilized for the rapid enumeration and analysis of cell specimens. Featuring automated operation, multiparameter analysis, and fluorescence detection capabilities, it is widely used in cell biology research, drug screening and related fields. This instrument serves as an essential tool in modern biological laboratories, utilizing automated processes and precision optical systems to deliver highly accurate and reproducible cell counting results, thereby enhancing experimental efficiency and ensuring reliable data outcomes.
-
1. High-performance hardware and configuration: Rapid computation, smooth analysis, and intelligent analysis without lag.
2. RCEC-A precision counting with intelligent recognition algorithm: 6 megapixel high-definition imaging, supporting statistical analysis of 3 fields of view for each of 6 samples, ensuring accurate and stable counting results and precise segmentation of cell clusters.
3. USB configuration interface: The software is easy to operate and the data management is traceable.
4. RCEC-A intuitive interface: Fingertip touchscreen operation is simple and convenient. A variety of built-in visual data analysis image modes are available. -
Precautions:
1. The equipment should be placed on a dry, sturdy and stable surface.
2. To protect the equipment, keep it away from moisture, dust, smoke, and direct sunlight.
3. The operating temperature should range from 4℃ to 40℃.
4. Handle supporting reagents(e.g., Trypan Blue) in strict compliance with all applicable safety regulations.
5. Do not power on this equipment in low-temperature environment. If the equipment is accidentally placed in low-temperature environment, please transfer the equipment to room temperature and leave it for at least 2 hours before use.
6. The device must not be placed on vibrating laboratory bench—ensure the platform remains stable and level.
7. Only trained personnel may operate this equipment in properly managed laboratory settings. When handling samples, proper personal protective equipment must be worn, especially gloves.
8. During fluorescence experiments, do not look directly into the sample inlet and the ventilation openings of the equipment.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation