Benchtop pH Meter
Benchtop pH Meter
RBPH-A
Brand:
RUISCI
-
Click to select
- RBPH-A-15,Normal,0~±1500mV
- RBPH-A-20,Normal,0~±1999mV
- RBPH-A-20s,Automatic Temperature Compensation,0~±1999mV
Inventory
705
隐藏域元素占位
Overview
Benchtop pH meter is a precise instrument used to measure the acidity or alkalinity of a solution. It converts the pH of the solution into an electrical signal by inserting electrodes into the sample solution, and then the internal circuit of the instrument processes and displays the pH value. It is widely used in water quality testing, chemical production, environmental monitoring, biomedical research and many other fields, and is an indispensable detection tool in laboratories and industrial production.
Features
1. Precise measurement: The measurement accuracy can reach 0.01.
2. Large LCD display: Clear display, easy to read.
3. Wide measurement range: It can measure a wide pH range from strong acids to strong bases.
4. Good stability: During long-term use, the readings are stable and not easily affected by environmental factors.
5. Automatic temperature compensation: It has an automatic temperature compensation function that can automatically adjust the pH reading according to the solution temperature.
6. Dual function: It can measure pH values and also measure electrode potential (mV values).
7. Quick response: It responds quickly to changes in solution pH and can display new readings promptly.
8. Durability: Sturdy structure, long service life, suitable for frequent use.
Technical data

Operation Precautions:
Before use:
1. Calibration: Calibrate with standard buffer solutions (such as pH 4.00, 6.86, 9.18) to ensure accurate readings.
2. Check the electrode: Inspect for damage and ensure the filling solution is sufficient.
During measurement:
3. Sample preparation: Ensure the sample temperature is close to the calibration temperature. Turbid samples should be filtered.
4. Electrode operation: Gently place the electrode into the sample, avoiding contact with the container wall. Record the reading after it stabilizes.
After use:
5. Clean the electrode: Rinse with distilled water. If necessary, soak in a mild solution and then rinse thoroughly.
6. Store the electrode: Immerse glass electrodes in a 3 mol/L potassium chloride solution. Follow the manufacturer's instructions for storing combination electrodes.
Other:
7. Avoid interference: Keep away from strong magnetic and electric fields.
8. Regular maintenance: Perform a comprehensive maintenance and calibration every 3 to 6 months.
Operating environment:
1. Relative humidity: <80%.
2. Ambient temperature: 5 - 40°C.
3. Sample solution temperature: 5 - 60°C.
4. Power supply: 220V/50Hz power supply.
5. No significant vibration or strong electromagnetic field interference.
keyword:
Benchtop pH Meter
Laboratory pH Meter
Precision pH Analyzer
Digital Dual-Function pH/mV Analyzer For Lab
pH Meter With Automatic Temperature Compensation
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Benchtop pH Meter
- Subtitle: Benchtop pH Meter
- Model: RBPH-A
- 全部型号: RBPH-A-15,RBPH-A-20,RBPH-A-20s,Benchtop pH Meter,Laboratory pH Meter,Precision pH Analyzer,Digital Dual-Function pH/mV Analyzer For Lab,pH Meter With Automatic Temperature Compensation
Benchtop pH meter is a precise instrument used to measure the acidity or alkalinity of a solution.
Benchtop pH meter is a precise instrument used to measure the acidity or alkalinity of a solution. It converts the pH of the solution into an electrical signal by inserting electrodes into the sample solution, and then the internal circuit of the instrument processes and displays the pH value. It is widely used in water quality testing, chemical production, environmental monitoring, biomedical research and many other fields, and is an indispensable detection tool in laboratories and industrial production.
-
1. Precise measurement: The measurement accuracy can reach 0.01.
2. Large LCD display: Clear display, easy to read.
3. Wide measurement range: It can measure a wide pH range from strong acids to strong bases.
4. Good stability: During long-term use, the readings are stable and not easily affected by environmental factors.
5. Automatic temperature compensation: It has an automatic temperature compensation function that can automatically adjust the pH reading according to the solution temperature.
6. Dual function: It can measure pH values and also measure electrode potential (mV values).
7. Quick response: It responds quickly to changes in solution pH and can display new readings promptly.
8. Durability: Sturdy structure, long service life, suitable for frequent use. -

Operation Precautions:
Before use:
1. Calibration: Calibrate with standard buffer solutions (such as pH 4.00, 6.86, 9.18) to ensure accurate readings.
2. Check the electrode: Inspect for damage and ensure the filling solution is sufficient.
During measurement:
3. Sample preparation: Ensure the sample temperature is close to the calibration temperature. Turbid samples should be filtered.
4. Electrode operation: Gently place the electrode into the sample, avoiding contact with the container wall. Record the reading after it stabilizes.
After use:
5. Clean the electrode: Rinse with distilled water. If necessary, soak in a mild solution and then rinse thoroughly.
6. Store the electrode: Immerse glass electrodes in a 3 mol/L potassium chloride solution. Follow the manufacturer's instructions for storing combination electrodes.
Other:
7. Avoid interference: Keep away from strong magnetic and electric fields.
8. Regular maintenance: Perform a comprehensive maintenance and calibration every 3 to 6 months.
Operating environment:
1. Relative humidity: <80%.
2. Ambient temperature: 5 - 40°C.
3. Sample solution temperature: 5 - 60°C.
4. Power supply: 220V/50Hz power supply.
5. No significant vibration or strong electromagnetic field interference.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.