Dissolved Oxygen Electrode
Dissolved Oxygen Electrode
DE-A
Brand:
RUISCI
-
Click to select
- DE-A-01,0.00~19.99 mg/L
Inventory
245
隐藏域元素占位
Overview
Dissolved oxygen electrodes are sensors employed to measure the dissolved oxygen content in water. Generally, they consist of a working electrode and a reference electrode, and detect the concentration of dissolved oxygen based on electrochemical principles. During the operation process, dissolved oxygen diffuses through a gas-permeable membrane and reacts with the electrode, thereby generating a current signal. The magnitude of this current is proportional to the concentration of dissolved oxygen.
Features
1. DIN Locking Connector:
Fitted with a DIN connector, it is characterized by a reliable locking mechanism. This mechanism ensures a secure connection, thereby guaranteeing operational safety.
2. Epoxy Resin Enclosure:
The enclosure is fabricated from robust epoxy resin material. It exhibits outstanding durability and remarkable resistance to breakage, which effectively extends the service life of the product.
3. Built - in Temperature Sensor:
A high - precision temperature sensor is integrated into the device. This sensor supports the function of automatic temperature compensation, ensuring the accuracy and reliability of measurement outcomes.
4. Threaded Membrane Cap Design:
The product features a user - centered threaded membrane cap design. This design greatly facilitates the maintenance of the membrane and enables rapid membrane replacement, thus enhancing work efficiency.
Technical data

Precautions:
1. Regularly clean the electrode to remove dirt and biofilm to maintain its sensitivity and response speed.
2. Use appropriate cleaning agents and soft cloths; avoid using hard brushes or rough materials that may damage the electrode membrane.
3. Cover the membrane cap promptly after use to prevent the electrode membrane from drying out, avoid prolonged exposure of the electrode to dry environments,which could affect measurement accuracy.
4. Regularly check the seal of the membrane cap to ensure it effectively protects the electrode.
5. Regularly calibrate the electrode using a standard solution of known dissolved oxygen concentration to ensure measurement accuracy.
6. Store the electrode in the recommended storage solution to keep the electrode membrane moist.
7. Replace the electrode membrane in a timely manner when it shows signs of aging or damage to ensure measurement accuracy.
8. During installation and use, avoid physical damage to the electrode, such as impacts or excessive bending.
9. Ensure the electrode cable is not pulled or compressed.
10. Install the electrode correctly to ensure the electrode membrane is fully submerged in water, avoiding air bubbles that could affect measurements.
11. Adjust the electrode depth as needed to obtain representative dissolved oxygen data.
12. Avoid contact of the electrode with chemicals that may contaminate or damage the electrode membrane.
13. Take appropriate protective measures when using the electrode in environments with chemicals.
14. Record the maintenance and calibration history of the electrode to facilitate tracking of its performance and lifespan.
15. Regularly check the performance of the electrode and address any issues promptly.
keyword:
Electrochemical Dissolved Oxygen Electrodes
DO Electrodes
Dissolved Oxygen Probe
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Dissolved Oxygen Electrode
- Subtitle: Dissolved Oxygen Electrode
- Model: DE-A
- 全部型号: DE-A-01,Electrochemical Dissolved Oxygen Electrodes,DO Electrodes,Dissolved Oxygen Probe
Dissolved oxygen electrodes are sensors employed to measure the dissolved oxygen content in water.
Dissolved oxygen electrodes are sensors employed to measure the dissolved oxygen content in water. Generally, they consist of a working electrode and a reference electrode, and detect the concentration of dissolved oxygen based on electrochemical principles. During the operation process, dissolved oxygen diffuses through a gas-permeable membrane and reacts with the electrode, thereby generating a current signal. The magnitude of this current is proportional to the concentration of dissolved oxygen.
-
1. DIN Locking Connector:
Fitted with a DIN connector, it is characterized by a reliable locking mechanism. This mechanism ensures a secure connection, thereby guaranteeing operational safety.
2. Epoxy Resin Enclosure:
The enclosure is fabricated from robust epoxy resin material. It exhibits outstanding durability and remarkable resistance to breakage, which effectively extends the service life of the product.
3. Built - in Temperature Sensor:
A high - precision temperature sensor is integrated into the device. This sensor supports the function of automatic temperature compensation, ensuring the accuracy and reliability of measurement outcomes.
4. Threaded Membrane Cap Design:
The product features a user - centered threaded membrane cap design. This design greatly facilitates the maintenance of the membrane and enables rapid membrane replacement, thus enhancing work efficiency. -

Precautions:
1. Regularly clean the electrode to remove dirt and biofilm to maintain its sensitivity and response speed.
2. Use appropriate cleaning agents and soft cloths; avoid using hard brushes or rough materials that may damage the electrode membrane.
3. Cover the membrane cap promptly after use to prevent the electrode membrane from drying out, avoid prolonged exposure of the electrode to dry environments,which could affect measurement accuracy.
4. Regularly check the seal of the membrane cap to ensure it effectively protects the electrode.
5. Regularly calibrate the electrode using a standard solution of known dissolved oxygen concentration to ensure measurement accuracy.
6. Store the electrode in the recommended storage solution to keep the electrode membrane moist.
7. Replace the electrode membrane in a timely manner when it shows signs of aging or damage to ensure measurement accuracy.
8. During installation and use, avoid physical damage to the electrode, such as impacts or excessive bending.
9. Ensure the electrode cable is not pulled or compressed.
10. Install the electrode correctly to ensure the electrode membrane is fully submerged in water, avoiding air bubbles that could affect measurements.
11. Adjust the electrode depth as needed to obtain representative dissolved oxygen data.
12. Avoid contact of the electrode with chemicals that may contaminate or damage the electrode membrane.
13. Take appropriate protective measures when using the electrode in environments with chemicals.
14. Record the maintenance and calibration history of the electrode to facilitate tracking of its performance and lifespan.
15. Regularly check the performance of the electrode and address any issues promptly.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.
Download
There is currently no content to display
Related products
Online consultation