Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Hollow Cathode Lamp - Glass
Hollow Cathode Lamp - Glass
HC-B
Brand:
RUISCI
-
Click to select
- HC-B-ER
- HC-B-LA
- HC-B-YB
- HC-B-LI
- HC-B-HO
- HC-B-GD
- HC-B-PR
- HC-B-RB
- HC-B-TB
- HC-B-ZR
- HC-B-SR
- HC-B-CA
- HC-B-SC
- HC-B-BA
- HC-B-CE
- HC-B-CR
- HC-B-DY
- HC-B-EU
- HC-B-K
- HC-B-NA
- HC-B-ND
- HC-B-SM
- HC-B-TM
- HC-B-Y
- HC-B-CS
Inventory
6700
隐藏域元素占位
Overview
The Hollow Cathode Lamp is a low-pressure gas discharge light source, mainly used in atomic absorption spectrometry analysis.
Features
Features:
1. Narrow Emission Line Half-width: Provides a sharp line light source, which is conducive to improving the sensitivity and selectivity of analysis.
2. High Intensity: The intensity of the emitted characteristic spectral lines is strong, meeting the needs of atomic absorption spectroscopy.
3. Good Signal-to-noise Ratio: The signal is stable with low noise, resulting in more accurate measurement results.
4. Long Service Life: With proper use and maintenance, it can work stably for a long time.
5. Good Light Transmission: It has a good transmittance for visible light and part of the ultraviolet light.
6. Moderate Stability: Its chemical stability is not as good as quartz, and its thermal stability is slightly inferior.
7. Limited Application: It is mainly used for analysis in the visible light region, and its performance in the ultraviolet region is not as good as that of quartz lamps.
Technical data

Precautions:
1. Warm-up: Preheat for 10-20 minutes before use to stabilize the emission intensity.
2. Current: Avoid overcurrent. Set the current according to the manual to prevent lamp damage.
3. Cleaning: Clean the glass window regularly to avoid dust and stains affecting the light transmission.
4. Storage: Store in a dry and clean environment to prevent moisture and corrosion.
5. Lifespan: Pay attention to the lamp's service life and replace aged lamps in time.
6. Matching: Ensure the lamp is compatible with the instrument to avoid compatibility issues.
keyword:
Hollow Cathode Lamp - Glass
Glass Window Hollow Cathode Lamp
Multi Element Hollow Cathode Lamps
Previous:
Next:
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Hollow Cathode Lamp - Glass
- Subtitle: Hollow Cathode Lamp - Glass
- Model: HC-B
- 全部型号: HC-B-ER,HC-B-LA,HC-B-YB,HC-B-LI,HC-B-HO,HC-B-GD,HC-B-PR,HC-B-RB,HC-B-TB,HC-B-ZR,HC-B-SR,HC-B-CA,HC-B-SC,HC-B-BA,HC-B-CE,HC-B-CR,HC-B-DY,HC-B-EU,HC-B-K,HC-B-NA,HC-B-ND,HC-B-SM,HC-B-TM,HC-B-Y,HC-B-CS,Hollow Cathode Lamp - Glass,Glass Window Hollow Cathode Lamp,Multi Element Hollow Cathode Lamps
The Hollow Cathode Lamp is a low-pressure gas discharge light source, mainly used in atomic absorption spectrometry analysis.
The Hollow Cathode Lamp is a low-pressure gas discharge light source, mainly used in atomic absorption spectrometry analysis.
-
Features:
1. Narrow Emission Line Half-width: Provides a sharp line light source, which is conducive to improving the sensitivity and selectivity of analysis.
2. High Intensity: The intensity of the emitted characteristic spectral lines is strong, meeting the needs of atomic absorption spectroscopy.
3. Good Signal-to-noise Ratio: The signal is stable with low noise, resulting in more accurate measurement results.
4. Long Service Life: With proper use and maintenance, it can work stably for a long time.
5. Good Light Transmission: It has a good transmittance for visible light and part of the ultraviolet light.
6. Moderate Stability: Its chemical stability is not as good as quartz, and its thermal stability is slightly inferior.
7. Limited Application: It is mainly used for analysis in the visible light region, and its performance in the ultraviolet region is not as good as that of quartz lamps. -

Precautions:
1. Warm-up: Preheat for 10-20 minutes before use to stabilize the emission intensity.
2. Current: Avoid overcurrent. Set the current according to the manual to prevent lamp damage.
3. Cleaning: Clean the glass window regularly to avoid dust and stains affecting the light transmission.
4. Storage: Store in a dry and clean environment to prevent moisture and corrosion.
5. Lifespan: Pay attention to the lamp's service life and replace aged lamps in time.
6. Matching: Ensure the lamp is compatible with the instrument to avoid compatibility issues.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly
Q
Payment methods:
A
1. On-line payment: Paypal
2. Off-line payment: Telegraphic Transfer (TT)
*All charges, except those incurred within our bank, are to be borne by the remitter. Insufficient payment will delay your shipment.