Infrared Inoculated Loop Sterilizer

Infrared Inoculated Loop Sterilizer

RSTE-A


RUISCI

Brand:

RUISCI


USD

94

Untaxed

EXW factory


  • Choice
    • RSTE-A-01,400/800℃,ϕ14
    • RSTE-A-02,400/850℃,ϕ14
    • RSTE-A-03,400/800℃,ϕ35
    • RSTE-A-04,400/850℃,ϕ35
    • RSTE-A-05,900-1300℃,ϕ15
Quantity
-
+

Inventory

840

隐藏域元素占位


Infrared Inoculated Loop Sterilizer is a kind of equipment using infrared heat to sterilize, which is widely used in laboratory to sterilize high temperature resistant items such as inoculation loop and inoculation needle.


1. High temperature mode sterilization, fast sterilization, no pollution.
2. Non-contact heating, no open flame, not afraid of wind, more safe and convenient.
3. Can be used in anaerobic environment.
4. Use special ceramic, anti-friction, anti-corrosion, high temperature resistance, not easy to crack.
5. Base weight, more stable.

Technical data

Precautions for the use of infrared inoculation loop sterilizer:
1. Ensure the power supply of the equipment is stable to avoid damage to the equipment or poor sterilization effect due to voltage fluctuations.
2. Use it in a well-ventilated environment. The ambient temperature should be between 5℃ and 40℃, and the relative humidity should not exceed 90%.
3. The low setting at 400℃ is for heat preservation, and the high setting at 825-850℃ is for sterilization.
4. It is recommended to switch to the low setting for heat preservation during intermittent operation. The low setting is for heat preservation during intermittent use, and the high setting is for sterilization. After preheating at the high setting for 10-15 minutes (or 4-6 minutes after switching from the low setting to the high setting), the instrument reaches the high-temperature sterilization state. Insert the inoculation loop into the center for 5-7 seconds.
5. The temperature around the quartz tube is approximately 200℃ during operation. Please pay attention to your own safety and avoid burns.
6. Only use the original and clean heating tubes provided by the manufacturer; otherwise, the sterilization temperature may decrease.
7. Regularly maintain and service the equipment to ensure its normal operation and service life.

keyword:

Next:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Infrared Inoculated Loop Sterilizer
    • Subtitle: Infrared Inoculated Loop Sterilizer
    • Model: RSTE-A
    • 全部型号: RSTE-A-01,RSTE-A-02,RSTE-A-03,RSTE-A-04,RSTE-A-05

    Infrared inoculation loop sterilizer is a kind of equipment using infrared heat to sterilize.

    Infrared Inoculated Loop Sterilizer is a kind of equipment using infrared heat to sterilize, which is widely used in laboratory to sterilize high temperature resistant items such as inoculation loop and inoculation needle.

  • 1. High temperature mode sterilization, fast sterilization, no pollution.
    2. Non-contact heating, no open flame, not afraid of wind, more safe and convenient.
    3. Can be used in anaerobic environment.
    4. Use special ceramic, anti-friction, anti-corrosion, high temperature resistance, not easy to crack.
    5. Base weight, more stable.

  • Precautions for the use of infrared inoculation loop sterilizer:
    1. Ensure the power supply of the equipment is stable to avoid damage to the equipment or poor sterilization effect due to voltage fluctuations.
    2. Use it in a well-ventilated environment. The ambient temperature should be between 5℃ and 40℃, and the relative humidity should not exceed 90%.
    3. The low setting at 400℃ is for heat preservation, and the high setting at 825-850℃ is for sterilization.
    4. It is recommended to switch to the low setting for heat preservation during intermittent operation. The low setting is for heat preservation during intermittent use, and the high setting is for sterilization. After preheating at the high setting for 10-15 minutes (or 4-6 minutes after switching from the low setting to the high setting), the instrument reaches the high-temperature sterilization state. Insert the inoculation loop into the center for 5-7 seconds.
    5. The temperature around the quartz tube is approximately 200℃ during operation. Please pay attention to your own safety and avoid burns.
    6. Only use the original and clean heating tubes provided by the manufacturer; otherwise, the sterilization temperature may decrease.
    7. Regularly maintain and service the equipment to ensure its normal operation and service life.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Nitrogen Evaporator

Price:

575

USD

Delivery:

30 Days


The nitrogen evaporator is a laboratory device mainly used for concentrating and drying samples.

Thermostatic Incubator

Price:

192

USD

Delivery:

30 Days


The Thermostatic Incubator is a piece of equipment utilized for maintaining a constant temperature.

Portable Thermostatic Incubator

Price:

207

USD

Delivery:

30 Days


The Portable Thermostatic Incubator is a small and portable laboratory apparatus.

Glass Bead Sterilizer,Dry Heat Sterilizer

Price:

400

USD

Delivery:

30 Days


The glass bead sterilizer is a kind of equipment that implements sterilization through high-temperature glass beads.

Dry Heat Sterilizer

Price:

2350

USD

Delivery:

30 Days


The dry heat sterilization oven is a kind of equipment that employs high-temperature dry air for sterilization.

Online consultation


Name:

Submit