Conductivity Meter
Conductivity Meter
RCME-A,RCME-B,RCME-C,RCME-D

Brand:
RUISCI
-
Choice
- RCME-A-01,Button Operated
- RCME-A-02,Button Operated
- RCME-A-03,Button Operated
- RCME-A-04,Button Operated
- RCME-A-05,Button Operated
- RCME-B-01,Touchscreen
- RCME-B-02,Touchscreen
- RCME-B-03,Touchscreen
- RCME-B-04,Touchscreen
- RCME-C-01,Portable,0~2000uS/cm
- RCME-C-02,Portable,0~20.00mS/cm
- RCME-C-03,Portable,0~1000ppm
- RCME-C-04,Portable,0~9999ppm
- RCME-D-01,Portable,Manual
- RCME-D-02,Portable,Manual Of Automatic
Inventory
2520
隐藏域元素占位
Overview
A conductivity meter is an instrument used to measure the electrical conductivity of liquids. Conductivity is an indicator of a substance's ability to conduct electricity, reflecting the concentration of ions and the mobility of charges in a liquid. It is commonly used to detect and control the purity, quality, or composition of liquids.
Features
1.The instrument incorporates an internal microprocessor chip, featuring high responsiveness and rapid processing capabilities.
2.Manual/Automatic temperature compensation: It is compatible with novel conductance electrodes and temperature electrodes.
3.A large-capacity storage is available for 2000 sets of measurement data.
Technical data
Environmental Requirements:
1. Temperature control: Conductivity meters usually need to be measured at a constant temperature to eliminate the influence of temperature changes on the experimental results. The optimal temperature range is typically 20-25℃.
2. Humidity regulation: Appropriate humidity levels should be maintained, generally within a relative humidity range of 40%-60%, to prevent moisture from affecting the internal circuits of the instrument.
3. Cleaning and dust prevention: The laboratory should be kept clean to avoid the influence of dust and dirt on the instrument, and certain dust prevention measures should be taken.
4. Stable power supply: A stable power supply is required. It is recommended to use an uninterruptible power supply(UPS) or a voltage stabilizer to avoid the impact of power fluctuations on the measurement results.
Precautions:
1. Electrode maintenance: The electrode is the core component of the conductivity meter and requires special protection. The electrode lead should not be damp and should be calibrated regularly to ensure measurement accuracy.
2. Shock and magnetic field protection: Strong vibration sources and strong magnetic field interference sources should be avoided to prevent affecting the measurement results and stability of the conductivity monitor.
3. Fire prevention and corrosion protection: Fire extinguishing equipment should be provided in the laboratory, and strong acids, strong alkali or other corrosive substances should be avoided to prevent damage or corrosion to the instrument.
4. Measurement method and sealing: When measuring the conductivity of pure water or ultrapure water, it is recommended to use a sealed cell for flow measurement under airtight conditions to avoid drift in the measurement value.
5. Regular inspection and maintenance: The equipment should be sent for inspection and maintenance regularly, including checking the wear of the electrode, cleaning the electrode, and calibrating the instrument.
6. Electrode Connector Protection: Prevent moisture to avoid unnecessary measurement errors.
7. Sample container cleaning: The container holding the solution to be measured must be clean and free of ionic contamination.
8. Temperature compensation: The impact of temperature varies significantly across solutions with different properties, and temperature compensation should be selectively applied based on the measured solution's characteristics.
keyword:
Conductivity Meter
Electrical Conductivity Instrument
Lab Conductivity Tester
Automatic Temperature Compensation Conductivity Instrument
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Conductivity Meter
- Subtitle: Conductivity Meter
- Model: RCME-A,RCME-B,RCME-C,RCME-D
- 全部型号: RCME-A-01,RCME-A-02,RCME-A-03,RCME-A-04,RCME-A-05,RCME-B-01,RCME-B-02,RCME-B-03,RCME-B-04,RCME-C-01,RCME-C-02,RCME-C-03,RCME-C-04,RCME-D-01,RCME-D-02,Conductivity Meter,Electrical Conductivity Instrument,Lab Conductivity Tester,Automatic Temperature Compensation Conductivity Instrument
A conductivity meter is an instrument used to measure the electrical conductivity of liquids.
A conductivity meter is an instrument used to measure the electrical conductivity of liquids. Conductivity is an indicator of a substance's ability to conduct electricity, reflecting the concentration of ions and the mobility of charges in a liquid. It is commonly used to detect and control the purity, quality, or composition of liquids.
-
1.The instrument incorporates an internal microprocessor chip, featuring high responsiveness and rapid processing capabilities.
2.Manual/Automatic temperature compensation: It is compatible with novel conductance electrodes and temperature electrodes.
3.A large-capacity storage is available for 2000 sets of measurement data. -
Environmental Requirements:
1. Temperature control: Conductivity meters usually need to be measured at a constant temperature to eliminate the influence of temperature changes on the experimental results. The optimal temperature range is typically 20-25℃.
2. Humidity regulation: Appropriate humidity levels should be maintained, generally within a relative humidity range of 40%-60%, to prevent moisture from affecting the internal circuits of the instrument.
3. Cleaning and dust prevention: The laboratory should be kept clean to avoid the influence of dust and dirt on the instrument, and certain dust prevention measures should be taken.
4. Stable power supply: A stable power supply is required. It is recommended to use an uninterruptible power supply(UPS) or a voltage stabilizer to avoid the impact of power fluctuations on the measurement results.Precautions:
1. Electrode maintenance: The electrode is the core component of the conductivity meter and requires special protection. The electrode lead should not be damp and should be calibrated regularly to ensure measurement accuracy.
2. Shock and magnetic field protection: Strong vibration sources and strong magnetic field interference sources should be avoided to prevent affecting the measurement results and stability of the conductivity monitor.
3. Fire prevention and corrosion protection: Fire extinguishing equipment should be provided in the laboratory, and strong acids, strong alkali or other corrosive substances should be avoided to prevent damage or corrosion to the instrument.
4. Measurement method and sealing: When measuring the conductivity of pure water or ultrapure water, it is recommended to use a sealed cell for flow measurement under airtight conditions to avoid drift in the measurement value.
5. Regular inspection and maintenance: The equipment should be sent for inspection and maintenance regularly, including checking the wear of the electrode, cleaning the electrode, and calibrating the instrument.
6. Electrode Connector Protection: Prevent moisture to avoid unnecessary measurement errors.
7. Sample container cleaning: The container holding the solution to be measured must be clean and free of ionic contamination.
8. Temperature compensation: The impact of temperature varies significantly across solutions with different properties, and temperature compensation should be selectively applied based on the measured solution's characteristics.
Q and A
Q
Distribution Modes:
A
Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.
*Other options:
1.Carriage Paid To (CPT)
DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.
2.Delivered Duty Paid(DDP)
DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.
3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.
*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly