Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Atomic Absorption Hood

Atomic Absorption Hood

AH-A,AH-B,


RUISCI

Brand:

RUISCI


USD

50

Untaxed

EXW factory


  • Choice
    • AH-A-01,300300*850mm,110mm,SUS201
    • AH-A-02,350*350*850mm,110mm,SUS201
    • AH-A-03,400*400*850mm,110mm,SUS201
    • AH-A-04,500*500* 850mm,110mm,SUS201
    • AH-A-05,600*600* 850mm,110mm,SUS201
    • AH-A-06,400*400* 850mm,160mm,SUS201
    • AH-A-07,500*500* 850mm,160mm,SUS201
    • AH-A-08,600*600* 850mm,160mm,SUS201
    • AH-A-01A,400*400 *1300~1700mm,110mm
    • AH-A-02A,500*500 *1300~1700mm,110mm
    • AH-A-03A,600*600 *1300~1700mm,110mm
    • AH-A-04A,400*400 *1300~1700mm,160mm
    • AH-A-05A,500*500 *1300~1700mm,160mm
    • AH-A-06A,600*600 *1300~1700mm,160mm
    • AH-A-01B,400*400 *1300~1700mm,110mm
    • AH-A-02B,500*500 *1300~1700mm,110mm
    • AH-A-03B,600*600 *1300~1700mm,110mm
    • AH-A-04B,400*400 *1300~1700mm,160mm
    • AH-A-05B,500*500 *1300~1700mm,160mm
    • AH-A-06B,600*600 *1300~1700mm,160mm
    • AH-B-01,400*400* 850mm,110mm,SUS304
    • AH-B-02,500*500* 850mm,110mm,SUS304
    • AH-B-03,600*600* 850mm,110mm,SUS304
    • AH-B-04,400*400* 850mm,160mm,SUS304
    • AH-B-05,500*500* 850mm,160mm,SUS304
    • AH-B-06,600*600* 850mm,160mm,SUS304
    • AH-B-01A,400*400*1300~1700mm,110mm
    • AH-B-02A,500*500 *1300~1700mm,110mm
    • AH-B-03A,600*600 *1300~1700mm,110mm
    • AH-B-04A,400*400 *1300~1700mm,160mm
    • AH-B-05A,500*500 *1300~1700mm,160mm
    • AH-B-06A,600*600 *1300~1700mm,160mm
    • AH-B-01B,400*400 *1300~1700mm,110mm
    • AH-B-02B,500*500 *1300~1700mm,110mm
    • AH-B-03B,600*600 *1300~1700mm,110mm
    • AH-B-04B,400*400 *1300~1700mm,160mm
    • AH-B-05B,500*500 *1300~1700mm,160mm
    • AH-B-06B,600*600 *1300~1700mm,160mm
Quantity
-
+

Inventory

10222

隐藏域元素占位


The Atomic Absorption Hood is a specialized ventilation device for laboratories, mainly used for precision instruments that involve high temperatures and local exhaust requirements. Its core function is to expel harmful gases, fumes, and volatile substances generated during experiments from the laboratory, ensuring the safety of laboratory personnel and the cleanliness of the experimental environment.


1. Thickened fixed base: Made of 2mm thick steel plate through bending, welding and grinding, it is firm and durable.
2. Telescopic and air valve regulator: Free to extend and retract, air volume can be freely adjusted, simple and practical.
3. Double-layer folded edge: Greater thickness, increased strength, and will not scratch hands.

Technical data

Precautions:
1. Installation location: Install above the instrument, with the hood opening approximately 350mm away from the instrument flame to avoid interfering with instrument operation.
2. Ventilation duct: The duct should be short and straight, with fewer bends to ensure smooth exhaust.
3. Wiring: Keeps all wires neatly organized and tangle-fre
4. Equipment inspection: Before use, check the equipment connection is stable and the exhaust system is functioning properly.
5. Airflow adjustment: Adjust the airflow according to the experimental requirements to avoid it being too large or too small.
6. Experimental operation: Ensure the hood opening is aligned with the gas source. After the experiment, keep the exhaust device running for 2 minutes.
7. Safety protection: Wear personal protective equipment to ensure operational safety.
8. Regular cleaning: Clean the accumulated dust and debris inside the hood and duct to prevent blockages.
9. Check for leaks: Regularly check the integrity of the seals and repair any leaks.
10. Maintain the exhaust system: Check the operation status of the exhaust fan and repair or replace it in time.
11. Anti-corrosion: Clean up any residual acid or alkali liquids to prevent equipment corrosion.

keyword:

Stainless Steel Atomic Absorption Hood

Atomic Absorption Fume Extractor

Previous:

Next:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Atomic Absorption Hood
    • Subtitle: Atomic Absorption Hood
    • Model: AH-A,AH-B,
    • 全部型号: Stainless Steel Atomic Absorption Hood, Atomic Absorption Fume Extractor,AH-A-01,AH-A-02,AH-A-03,AH-A-04,AH-A-05,AH-A-06,AH-A-07,AH-A-08,AH-A-01A,AH-A-02A,AH-A-03A,AH-A-04A,AH-A-05A,AH-A-06A,AH-A-01B,AH-A-02B,AH-A-03B,AH-A-04B,AH-A-05B,AH-A-06B,AH-B-01,AH-B-02,AH-B-03,AH-B-04,AH-B-05,AH-B-06,AH-B-01A,AH-B-02A,AH-B-03A,AH-B-04A,AH-B-05A,AH-B-06A,AH-B-01B,AH-B-02B,AH-B-03B,AH-B-04B,AH-B-05B,AH-B-06B

    The Atomic Absorption Hood is a specialized ventilation device for laboratories, mainly used for precision instruments that involve high temperatures and local exhaust requirements.

    The Atomic Absorption Hood is a specialized ventilation device for laboratories, mainly used for precision instruments that involve high temperatures and local exhaust requirements. Its core function is to expel harmful gases, fumes, and volatile substances generated during experiments from the laboratory, ensuring the safety of laboratory personnel and the cleanliness of the experimental environment.

  • 1. Thickened fixed base: Made of 2mm thick steel plate through bending, welding and grinding, it is firm and durable.
    2. Telescopic and air valve regulator: Free to extend and retract, air volume can be freely adjusted, simple and practical.
    3. Double-layer folded edge: Greater thickness, increased strength, and will not scratch hands.

  • Precautions:
    1. Installation location: Install above the instrument, with the hood opening approximately 350mm away from the instrument flame to avoid interfering with instrument operation.
    2. Ventilation duct: The duct should be short and straight, with fewer bends to ensure smooth exhaust.
    3. Wiring: Keeps all wires neatly organized and tangle-fre
    4. Equipment inspection: Before use, check the equipment connection is stable and the exhaust system is functioning properly.
    5. Airflow adjustment: Adjust the airflow according to the experimental requirements to avoid it being too large or too small.
    6. Experimental operation: Ensure the hood opening is aligned with the gas source. After the experiment, keep the exhaust device running for 2 minutes.
    7. Safety protection: Wear personal protective equipment to ensure operational safety.
    8. Regular cleaning: Clean the accumulated dust and debris inside the hood and duct to prevent blockages.
    9. Check for leaks: Regularly check the integrity of the seals and repair any leaks.
    10. Maintain the exhaust system: Check the operation status of the exhaust fan and repair or replace it in time.
    11. Anti-corrosion: Clean up any residual acid or alkali liquids to prevent equipment corrosion.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Friability Tester

Price:

625

USD

Delivery:

30 Days


The friability tester is an apparatus employed to evaluate the resistance of tablets to fragmentation under physical impact.

Residual Chlorine Colorimeter

Price:

150

USD

Delivery:

30 Days


The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring.

Flexible Fume Extraction Hood

Price:

8

USD

Delivery:

7 Days


The Flexible Fume Extraction Hood is a commonly used fume exhaust instrument in laboratories.

Ion meter

Price:

2143

USD

Delivery:

30 Days


Ion meter is an electrochemical analytical apparatus employed for the determination of ionic concentrations in solutions.

Cell Counter

Price:

2138

USD

Delivery:

30 Days


The Cell Counter is a high-precision apparatus utilized for the rapid enumeration and analysis of cell specimens.

Online consultation


Name:

Submit