Close
  • Comparison
  • 在线预约
  • 预约申请
  • 样品申请
  • 在线询价
Total X Clear all

Residual Chlorine Colorimeter

Residual Chlorine Colorimeter

RRES-A


RUISCI

Brand:

RUISCI


USD

150

Untaxed

EXW factory


  • Choice
    • RRES-A-05,0~5mg/L
    • RRES-A-10,0~10mg/L
Quantity
-
+

Inventory

336

隐藏域元素占位


The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring. Based on the colorimetric principle, the residual chlorine colorimeter reacts with the residual chlorine or total chlorine in water samples through chemical reagents to generate compounds with specific colors. The intensity of the resulting color is directly proportional to the chlorine concentration. The optical system of the colorimeter measures its absorbance, thereby determining the concentration of residual chlorine or total chlorine in the water sample.


1. Rapid detection: It can complete the measurement in a short time and is suitable for on-site rapid detection.
2. Portability: Small in size and light in weight, it is easy to carry and operate, and is suitable for outdoor and on-site use.
3. High precision: Advanced optical technology and calibration methods are adopted to ensure the accuracy and reliability of the measurement results.
4. High-definition large screen: Color high-definition TFT screen for clearer reading.
5. ATC automatic temperature compensation: Equipped with automatic temperature compensation function for more accurate instrument readings.
6. Multi-parameter measurement: Simultaneously measures multiple parameters such as residual chlorine, total chlorine, and chlorine dioxide.

Technical data

Precautions:
1. Check if the appearance of the instrument is intact to ensure normal operation.
2. Collect fresh samples and measure them as soon as possible to avoid chlorine volatilization.
3. Use clean containers to prevent sample contamination.
4. Align with the mark when placing it into the instrument.
5. Add reagents as required to avoid overuse or shortage.
6. Store reagents properly to prevent moisture or expiration.
7. Calibrate the zero point before measurement.
8. Avoid strong light interference and control the color development time.
9. Measure the same sample multiple times and take the average value.
10. Place the instrument stably and keep it away from strong magnetic fields and high temperatures.
11. Wear protective gear during operation to prevent reagent contact with skin.

keyword:

Residual Chlorine Colorimeter

Chlorine Tester

Portable Free Chlorine Analyzer

Water Treatment Chlorine Meter

Previous:

Next:

  • 产品描述
  • 概要参数
  • 技术参数
    • Brand: RUISCI
    • Commodity name: Residual Chlorine Colorimeter
    • Subtitle: Residual Chlorine Colorimeter
    • Model: RRES-A
    • 全部型号: RRES-A-05,RRES-A-10,Residual Chlorine Colorimeter,Chlorine Tester,Portable Free Chlorine Analyzer,Water Treatment Chlorine Meter

    The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring.

    The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring. Based on the colorimetric principle, the residual chlorine colorimeter reacts with the residual chlorine or total chlorine in water samples through chemical reagents to generate compounds with specific colors. The intensity of the resulting color is directly proportional to the chlorine concentration. The optical system of the colorimeter measures its absorbance, thereby determining the concentration of residual chlorine or total chlorine in the water sample.

  • 1. Rapid detection: It can complete the measurement in a short time and is suitable for on-site rapid detection.
    2. Portability: Small in size and light in weight, it is easy to carry and operate, and is suitable for outdoor and on-site use.
    3. High precision: Advanced optical technology and calibration methods are adopted to ensure the accuracy and reliability of the measurement results.
    4. High-definition large screen: Color high-definition TFT screen for clearer reading.
    5. ATC automatic temperature compensation: Equipped with automatic temperature compensation function for more accurate instrument readings.
    6. Multi-parameter measurement: Simultaneously measures multiple parameters such as residual chlorine, total chlorine, and chlorine dioxide.

  • Precautions:
    1. Check if the appearance of the instrument is intact to ensure normal operation.
    2. Collect fresh samples and measure them as soon as possible to avoid chlorine volatilization.
    3. Use clean containers to prevent sample contamination.
    4. Align with the mark when placing it into the instrument.
    5. Add reagents as required to avoid overuse or shortage.
    6. Store reagents properly to prevent moisture or expiration.
    7. Calibrate the zero point before measurement.
    8. Avoid strong light interference and control the color development time.
    9. Measure the same sample multiple times and take the average value.
    10. Place the instrument stably and keep it away from strong magnetic fields and high temperatures.
    11. Wear protective gear during operation to prevent reagent contact with skin.

Q and A


Q

Distribution Modes:

A

Default Distribution Mode: EXW China Factory: After your payment is received, our customer service will contact you to confirm the pickup time and location once the goods are ready at the RUISCI China factory.

*Other options:

1.Carriage Paid To (CPT)

DO NOT PAY until you have contacted customer service to add shipping costs, as the default price is EXW China factory.

2.Delivered Duty Paid(DDP)

DO NOT PAY until you have ·contacted customer service to add Freight, insurance, taxes, customs clearance fees, and other miscellaneous expenses, as the default price is EXW China factory. Typically applies exclusively to small air cargo packages.

3. FOB China main port
DO NOT PAY until you have contacted customer service to add the inland charges and export declaration charges, as the default price is EXW China factory.

 

*** If you still need to consult other distribution modes or trade terms, please contact our customer service directly


Q

Payment methods:

A

1. On-line payment: Paypal

2. Off-line payment: Telegraphic Transfer (TT)

 

*All charges, except those incurred within our bank, are to be borne by the remitter.  Insufficient payment will delay your shipment.


Download


There is currently no content to display

Related products


Ion meter

Price:

2143

USD

Delivery:

30 Days


Ion meter is an electrochemical analytical apparatus employed for the determination of ionic concentrations in solutions.

Conductivity Meter

Price:

335

USD

Delivery:

30 Days


A conductivity meter is an instrument used to measure the electrical conductivity of liquids.

Cell Counter

Price:

2138

USD

Delivery:

30 Days


The Cell Counter is a high-precision apparatus utilized for the rapid enumeration and analysis of cell specimens.

Height And Weight Scale

Price:

171

USD

Delivery:

30 Days


A height and weight measuring scale is a piece of equipment capable of concurrently measuring an individual's height and weight.

PAP Pen

Price:

66

USD

Delivery:

7 Days


The Liquid Blocker Super Pen is primarily employed in staining experiments such as immunohistochemistry or immunofluorescence.

Online consultation


Name:

Submit