Quality Assured
Just Buy It
- Comparison
- 在线预约
- 预约申请
- 样品申请
- 在线询价
Residual Chlorine Colorimeter
Residual Chlorine Colorimeter
RRES-A
Brand:
RUISCI
-
Click to select
- RRES-A-05,0~5mg/L
- RRES-A-10,0~10mg/L
Inventory
336
隐藏域元素占位
Overview
The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring. Based on the colorimetric principle, the residual chlorine colorimeter reacts with the residual chlorine or total chlorine in water samples through chemical reagents to generate compounds with specific colors. The intensity of the resulting color is directly proportional to the chlorine concentration. The optical system of the colorimeter measures its absorbance, thereby determining the concentration of residual chlorine or total chlorine in the water sample.
Features
1. Rapid detection: It can complete the measurement in a short time and is suitable for on-site rapid detection.
2. Portability: Small in size and light in weight, it is easy to carry and operate, and is suitable for outdoor and on-site use.
3. High precision: Advanced optical technology and calibration methods are adopted to ensure the accuracy and reliability of the measurement results.
4. High-definition large screen: Color high-definition TFT screen for clearer reading.
5. ATC automatic temperature compensation: Equipped with automatic temperature compensation function for more accurate instrument readings.
6. Multi-parameter measurement: Simultaneously measures multiple parameters such as residual chlorine, total chlorine, and chlorine dioxide.
Technical data

Precautions:
1. Check if the appearance of the instrument is intact to ensure normal operation.
2. Collect fresh samples and measure them as soon as possible to avoid chlorine volatilization.
3. Use clean containers to prevent sample contamination.
4. Align with the mark when placing it into the instrument.
5. Add reagents as required to avoid overuse or shortage.
6. Store reagents properly to prevent moisture or expiration.
7. Calibrate the zero point before measurement.
8. Avoid strong light interference and control the color development time.
9. Measure the same sample multiple times and take the average value.
10. Place the instrument stably and keep it away from strong magnetic fields and high temperatures.
11. Wear protective gear during operation to prevent reagent contact with skin.
keyword:
Residual Chlorine Colorimeter
Chlorine Tester
Portable Free Chlorine Analyzer
Water Treatment Chlorine Meter
- 产品描述
- 概要参数
- 技术参数
-
- Brand: RUISCI
- Commodity name: Residual Chlorine Colorimeter
- Subtitle: Residual Chlorine Colorimeter
- Model: RRES-A
- 全部型号: RRES-A-05,RRES-A-10,Residual Chlorine Colorimeter,Chlorine Tester,Portable Free Chlorine Analyzer,Water Treatment Chlorine Meter
The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring.
The residual chlorine colorimeter is an instrument used for rapid detection of residual chlorine and total chlorine content in water, and is widely applied in the field of water quality monitoring. Based on the colorimetric principle, the residual chlorine colorimeter reacts with the residual chlorine or total chlorine in water samples through chemical reagents to generate compounds with specific colors. The intensity of the resulting color is directly proportional to the chlorine concentration. The optical system of the colorimeter measures its absorbance, thereby determining the concentration of residual chlorine or total chlorine in the water sample.
-
1. Rapid detection: It can complete the measurement in a short time and is suitable for on-site rapid detection.
2. Portability: Small in size and light in weight, it is easy to carry and operate, and is suitable for outdoor and on-site use.
3. High precision: Advanced optical technology and calibration methods are adopted to ensure the accuracy and reliability of the measurement results.
4. High-definition large screen: Color high-definition TFT screen for clearer reading.
5. ATC automatic temperature compensation: Equipped with automatic temperature compensation function for more accurate instrument readings.
6. Multi-parameter measurement: Simultaneously measures multiple parameters such as residual chlorine, total chlorine, and chlorine dioxide. -

Precautions:
1. Check if the appearance of the instrument is intact to ensure normal operation.
2. Collect fresh samples and measure them as soon as possible to avoid chlorine volatilization.
3. Use clean containers to prevent sample contamination.
4. Align with the mark when placing it into the instrument.
5. Add reagents as required to avoid overuse or shortage.
6. Store reagents properly to prevent moisture or expiration.
7. Calibrate the zero point before measurement.
8. Avoid strong light interference and control the color development time.
9. Measure the same sample multiple times and take the average value.
10. Place the instrument stably and keep it away from strong magnetic fields and high temperatures.
11. Wear protective gear during operation to prevent reagent contact with skin.